Sanyo PDG-DET100L Service Manual page 55

Hide thumbs Also See for PDG-DET100L:
Table of Contents

Advertisement

Electrical Adjustment
Grp / No.
Item
34
Eco1 Fan A Min
35
Eco1 Fan A Max
36
Eco1 Fan B/C Min
37
Eco1 Fan B/C Max
38
Eco1 Fan D/E Min
39
Eco1 Fan D/E Max
40
Eco1 Fan F/G Min
41
Eco1 Fan F/G Max
42
Eco1 Fan H Min
43
Eco1 Fan H Max
48
Eco2 Fan Control Min Temp
49
Eco2 Fan Control Max Temp
50
Eco2 Fan A Min
51
Eco2 Fan A Max
52
Eco2 Fan B/C Min
53
Eco2 Fan B/C Max
54
Eco2 Fan D/E Min
55
Eco2 Fan D/E Max
56
Eco2 Fan F/G Min
57
Eco2 Fan F/G Max
58
Eco2 Fan H Min
59
Eco2 Fan H Max
255
Fan Start/Cooling Setting
0
Fan A Initial Volt
1
Fan B/C Initial Volt
2
Fan D/E Initial Volt
3
FanF/G Initial Volt
4
FanH Initial Volt
8
Cooling Time
10
Temp Error Cooling Time
11
OnStart Cooling Start Threshold
12
After shutdown cooling
256
0
1
2
259
Fan Air Pressure Setting
0
Press Source Range Low
1
Press Source Range High
2
Press Fan Add Range High
3
Press Fan Add Range Low
4
Temp C-A Upward High
5
Temp C-A Upward Low
6
Temp C-A Downward High
7
Temp C-A Downward Low
260
Auto Calibration (Common)
0
Execute Calibration
1
Loop Count
2
Auto Status
3
AutoWait
4
CHECK - Tolerance
5
Time out wait
100 Route Switch
261
Auto Calibration (RGB)
0
OFFSET AREA H START
1
OFFSET AREA V START
2
GAIN AREA H START
Function
Fan Voltage Set at Eco1 (Min/Max) (V)
Temp Sensor Control Start/End Temp at Eco2
Fan Voltage Set at Eco2 (Min/Max) (V)
Fan Start Voltage (0.1V)
Cooling Time Setting (x30 sec.) 1: 30 3: 90 15: 450
Cooling Time Setting When the Temp Error occurs (x30 sec.)
1: 30 3: 90 15: 450
Cooling Operation after Shut Down (0: No, 1: Yes)
Pressure Sensor Control Range Setting (AD)
Pressure Sensor Fan Control Add. Voltage (x0.1)
Fan Voltage Add Upward (Sensor A-C) High
Fan Voltage Add Upward (Sensor A-C) Low
Fan Voltage Add Downward (Sensor A-C) High
Fan Voltage Add Downward (Sensor A-C) Low
Execute Calibration when the Value is changed to 1. (For PC
White 100%)
Max Times of Calibration
Calibration Log (Read only)
0: Calibration End Correctly 1: On Adjusting 9: Calibration
Error
Waiting time
Tolerance of Offset
Wait Time until Time out [sec.]
0: Menu
1: Input1 - RGB Analog (OnBoard - Ext.ADC)
2: Input3 - RGB Analog (Slot - Ext.ADC)
3: Input1 - RGB Analog (OnBoard - Int.ADC)
4: Input2 - YCbCr (OnBoard - Ext.ADC)
5: Input2 - YCbCr (OnBoard - Int.ADC)
6: Input2 - Video (OnBoard - Int.VDD)
PW392-AFE MDL <10bits>
Black Level Acq. Area H Start
Black Level Acq. Area V Start
White Level Acq. Area H Start
Range
0000-9990
50 50 50 50 50 50 50 50
0000-9990
90 90 90 90 90 90 90 90
0000-9990
40 60 70 70 70 70 70 60
0000-9990
40 60 70 70 70 70 70 60
0000-9990
58 58 58 58 58 58 58 58
0000-9990
125 125 125 125 125 125 125 125
0000-9990
78 78 78 78 78 78 78 78
0000-9990
125 125 125 125 125 125 125 125
0000-9990
65 65 65 65 65 65 65 65
0000-9990
120 120 120 120 120 120 120 120
20-100
27 27 27 27 27 27 27 27
20-100
37 37 37 37 37 37 37 37
0000-9990
60 60 60 60 60 60 60 60
0000-9990
90 90 90 90 90 90 90 90
0000-9990
40 60 70 70 70 70 70 60
0000-9990
40 60 70 70 70 70 70 60
0000-9990
70 70 70 70 70 70 70 70
0000-9990
130 130 130 130 130 130 130 130
0000-9990
85 85 85 85 85 85 85 85
0000-9990
130 130 130 130 130 130 130 130
0000-9990
75 75 75 75 75 75 75 75
0000-9990
130 130 130 130 130 130 130 130
0-255
0-255
0-255
0-255
0-255
1-15
1-15
0-100
0-1
0-1024
0-1024
0 - 2000
0 - 2000
0 - 1000
0 - 1000
0 - 1000
0 - 1000
0 - 1
1 - 30
0 / 1 / 9
1 - 20
1 - 255
1 - 255
0 - 6
0 - 1000
0 - 1000
0 - 1000
-55-
Initial
Note
70
70
70
70
70
3
5
50
1
632
810
0
65
23
21
20
19
0
8
0
3
4
20
-
975
500
25

Advertisement