Sanyo PDG-DWL100 - WXGA DLP Projector Command Manual

Rs232c basic
Hide thumbs Also See for PDG-DWL100 - WXGA DLP Projector:

Advertisement

BASIC SERIAL COMMAND SPECIFICATIONS
PDG-DWL100
Ver. 1.00
SANYO Electric Co., Ltd
DS Company
Projector Division

Advertisement

Table of Contents
loading

Summary of Contents for Sanyo PDG-DWL100 - WXGA DLP Projector

  • Page 1 BASIC SERIAL COMMAND SPECIFICATIONS PDG-DWL100 Ver. 1.00 SANYO Electric Co., Ltd DS Company Projector Division...
  • Page 2: Table Of Contents

    PDG-DWL100 Basic Serial Command Specifications ÿ CONTENTS ÿ Overview .........................4 Serial Interface Specification ..................4 Transfer Specification ....................4 Connection ......................4 Notes for Communication .....................5 Functional Execution Command Table ................6 Status Read Command Table ..................6 Functional Execution Command ..................7 Format ........................7 Functions which need command pipelining............7 Example Transferred ....................7 Operation Requirements ..................8 POWER ON Command ...................9...
  • Page 3 PDG-DWL100 Basic Serial Command Specifications 6.32 YPbPr 1 Command ....................14 6.33 POINTER RIGHT Command ................14 6.34 POINTER LEFT Command .................. 14 6.35 POINTER UP Command ..................14 6.36 POINTER DOWN Command ................14 6.37 ENTER Command ....................14 6.38 FREEZE ON Command ..................
  • Page 4: Overview

    PDG-DWL100 Basic Serial Command Specifications Overview 1.1. This specification defines projector control commands for the PDG-DWL100 series. 1.2. The projector control commands are designed to remote-control a projector through RS-232C and LAN from a computer. Serial Interface Specification Transfer Specification Items Specification Synchronous system...
  • Page 5: Notes For Communication

    PDG-DWL100 Basic Serial Command Specifications Notes for Communication 3.1. The communication speed can be changed in menu. It starts to decode when the projector receives the carriage return (0x0D). 3.2. There are two types of command; the one is the Functional Execution Commands that execute almost the same function as the keys on the projector body, and the other one is the Status Read Commands that get basic status of the projector.
  • Page 6: Functional Execution Command Table

    PDG-DWL100 Basic Serial Command Specifications Functional Execution Command Table Command Command Item Item POWER ON YPbPr 2 POWER OFF (Immediate POWER OFF) HDMI Scart Computer 1 IMAGE(Toggle) Computer 2 D.zoom + Volume + D.zoom - Volume - Video SOUND MUTE ON S-Video SOUND MUTE OFF YPbPr 1...
  • Page 7: Functional Execution Command

    PDG-DWL100 Basic Serial Command Specifications Functional Execution Command Format PC issues a command in the format below: “C” Command [CR] Command: 2 characters (Refer to the Functional Execution Command Table.) The projector decodes the received data and returns the result after getting ready to receive another command.
  • Page 8: 6.4 Operation Requirements

    PDG-DWL100 Basic Serial Command Specifications 6.4 Operation Requirements The Functional Execution Commands are limited, when the projector is in the status below. (The Status Read Commands are available in following status.) Projector Status Available Functional Execution Commands In Standby mode C00: POWER ON Cooling Down in process NONE (No Execution)
  • Page 9: Power On Command

    PDG-DWL100 Basic Serial Command Specifications POWER ON Command COMMAND “C00” [CR] Set Power On. (Same as the “Power On” key on the projector body / remote controller.) Detail No operation is started when the projector has been turned on already. “Count Down”...
  • Page 10: Volume - Command

    PDG-DWL100 Basic Serial Command Specifications 6.11 Volume - Command COMMAND “C0A” [CR] This command turns down the Volume. This command works the same as “VOLUME ÿ ” button of the projector and Detail remote control. The projector shows the OSD “Volume” at receiving the command. Acceptable [ACK] [CR] Response...
  • Page 11: Video Mute Off Command

    PDG-DWL100 Basic Serial Command Specifications 6.15 Video Mute OFF Command COMMAND “C0E” [CR] This command sets AV Mute OFF. It releases the “Video Mute”, but does not release “Sound Mute”. It works immediately after the command is transmitted. Detail The projector shows the OSD “AV-Mute” at receiving command. This command works only for “AV-Mute OFF”...
  • Page 12: Image Mode Srgb Command

    PDG-DWL100 Basic Serial Command Specifications 6.20 Image mode sRGB Command COMMAND “C13” [CR] Set Image mode to sRGB. Detail This command changes Image mode immediately into sRGB. The projector shows the OSD “sRGB” on the screen at receiving the command. Acceptable [ACK] [CR] Response...
  • Page 13: Scart Command

    PDG-DWL100 Basic Serial Command Specifications 6.26 Scart Command COMMAND “C26” [CR] Select “Scart” Detail The projector shows the OSD “Scart” at receiving the command. Acceptable [ACK] [CR] Response Unacceptable “?” [CR] 6.27 IMAGEÿ Toggleÿ Command COMMAND “C27” [CR] Switch Images setting along the order below. Presentation →...
  • Page 14: Ypbpr 1 Command

    PDG-DWL100 Basic Serial Command Specifications 6.32 YPbPr 1 Command COMMAND “C35” [CR] Select “YPbPr 1” Detail The projector shows the OSD “YPbPr 1” at receiving the command. Acceptable [ACK] [CR] Response Unacceptable “?” [CR] 6.33 POINTER RIGHT Command COMMAND “C3A” [CR] Move Pointer of OSD Menu to right.
  • Page 15: Freeze On Command

    PDG-DWL100 Basic Serial Command Specifications 6.38 FREEZE ON Command COMMAND “C43” [CR] Freeze the projecting image. The behavior is the same as “FREEZE” button of the remote control except the Detail command only freezes the image and does not cancel it. The projector shows the OSD “Freeze”...
  • Page 16: Status Read Command

    PDG-DWL100 Basic Serial Command Specifications Status Read Command Format PC issues a command in the format below: “CR” Command [CR] Command: Single character (Refer to Status Read Command Table) When a projector receives the appropriate command, it returns the required information as a data string.
  • Page 17: Status Read Command

    PDG-DWL100 Basic Serial Command Specifications Status Read Command COMMAND “CR0” [CR] Detail Get the projector status Acceptable “%1” [CR] “00” = Power ON “80” = Standby “20” = Cooling Down in process Response “10” = Power Failure “28” = Cooling Down due to Abnormal Temperature in process “21”...
  • Page 18: Input Mode Read Command

    PDG-DWL100 Basic Serial Command Specifications Even if the temperature comes down during this process, the given Cooling Down process is executed and it moves to Standby mode. 0û “21” [CR] Status: Cooling Down in process after turned off due to lamp failure When a projector is turned off because of lamp failure, it automatically starts Cooling Down operation, in which the projector returns “21”...
  • Page 19: Temp Read Command

    PDG-DWL100 Basic Serial Command Specifications Temp Read Command COMMAND “CR6” [CR] Get the temperature information inside projector Detail With more than one temperature sensors installed in the projector, it is possible to get all temperatures at once. Acceptable “%1” [CR] %1 = temperature at Sensor 1 Temperature data is expressed as “00.0”.

Table of Contents