When checking with two or more satellite machines connected,
enter the terminal No. (000 ∼ 015) and press the ENTER key
for each satellite connected. To execute, press the ENTER key
without entering the terminal No. The display is as shown be-
low. Do not use the same terminal No. for different machines
(master/satellite).
Data Transmission Check (Master)
Input Master Terminal Number
Input Satellite Terminal Number : xxx
xxx xxx xxx xxx xxx
Data Sequence Number
With the above setting, data transmission between the master
machine and the satellite machine is started.
Check content
Data in the following format composed of 2byte sequence No.
and 254byte AAH data are transmitted from the master ma-
chine to the satellite machine. The master machine displays the
sequence No.
Test data format (1 packet = 256byte)
1
2
3
4
5
XX
XX
AA
AA
AA
XXXX
: Sequence No. (2byte: 4digits of binary decimal numbers)
AA
: Transmission data (AAH) x 254 bytes
The satellite machine sends back the received data to the mas-
ter machine. The satellite machine displays the received se-
quence No.
The master machine receives the data, and checks the se-
quence No. and 256byte AAH data. In case of an error, the
master machine displays an error code and terminates the
check. If two or more satellite machines are used, the above
operation is repeated. If data transmission with all the satellite
machines are normally completed, the master machine incre-
ments the sequence No.
The above operation is repeated.
!
Error display
Data Transmission Check (Master)
Input Master Terminal Number
Input Satellite Terminal Number : xxx
xxx xxx xxx xxx xxx
Data Sequence Number
IRC Error
: xxx
: 0000
254
255
256
Byte
AA
AA
AA
: xxx
: xxxx
: xx
The
error
code is
displayed
.
6 – 9
The error codes are as shown below.
01 Command abnormality (except for during transmission)
02 No data received.
03 Received data present.
Received data remained.
04 Remote station not ready (in sending)
"NTDY" is sent back because the remote station is not ready
for reception.
05 Reception buffer full (in sending)
The controller reception buffer of the remote machine is full.
06 Resend error (in sending)
Retry over (5 times) when no response
07 Collision error (in sending)
When an collision occurred in data transmission, retry over
(16 times) at re-collision after a random time (0 ∼ 255ms).
08 Line busy time out
Transmission cannot be made by multi-station communication
to cause time out in data send wait time.
09 Reception size over (in receiving)
The reception buffer size is insufficient.
0A Hardware error
Interface abnormality (No SRN interface or abnormality in
SRN controller)
!
Terminating procedure
Press the Touch panel to terminate the check.
3-10. IrDA & ASK Diagnostics
This is used to check the IR communication.
To execute this check, the following composition is required.
UP-3300
UP-3300 as checker
The following menu is displayed. Press the touch key for the opera-
tion you want to execute to execute individual Diag programs.
Pressing the CANCEL key returns the screen to the Diag MAIN
menu.
IR(IrDA & ASK) Diagnostics
IrDA & ASK Check
IrDA & ASK Check
(CHECKER MODE)
Data Check (Receive MODE)
Data Check (Send MODE)
IrDA, ASK & SRN Check
(CHECKER)
CAUTION: IrDA, ASK & SRN check (CHECKER) is used only in
the production process, and must be not used in
servicing.
Cancel