System Installation
g.
Ensure that infinite resistance (open circuit) exists between
all terminal
block connections
and the ground lug
shown in
figure 11-6.
h.
If necessary, reconfigure the Power Control Module input
VAC
rating
plates
located under the main circuit breaker to re-
flect the current isolation transformer strapping.
i.
Replace the isolation transformer primary
side
cover
plate
and the equipment bay right-side panel.
11-13. Cable Connections
Step-by-step equipment bay(s) cable connection
instructions
are
contained
in
the
HP
3000 Computer System Installation Manual,
part no. 30000-90147.
11-14. PERIPHERAL DEVICE INSTALLATION
Installation instructions for peripheral devices that are part of
a standard computer system are contained in the HP 3000
Computer
System
Installation
Manual, part no. 30000-90147.
Installation
instructions for
all other peripheral
devices must
be obtained
from the
individual
instruction
manuals supplied
with the de-
vices.
11-15. NEW INSTALLATION TURN-ON
Do not attempt to turn-on a newly installed system until the iso-
lation transformer has been properly strapped,
all cableconnec-
tions completed,
all per ipheral . devices installed,
and the I/O
system properly
configured in accordance
with the
instructions
contained
in the
HP
3000 Compute r Sys tern
Installa tion Manual,
part no. 30000-90147.
After this has been accomplished,
perform
the following steps to turn-on the system for the first time.
a.
Se t the Power Control and Display Panel DC
POWER
LOGI C and
MEMORY
sw itches
to
DISABLE. (The Power Control and Display
Panel
is
loca ted at the bot tom fr ont
of
the
CPU
equipment
bay. )
b.
Ensure that the
Power Cbntrol
Mbdule
MAIN POWER,
INTERNAL
POWER,
and SWITCHED 120V OUTLETS
circuit breakers are still
set to their
OFF positions and connect the main
power cable
to the customer-furnished AC power source.
c.
Set the
MAIN POWER
circuit breaker to its
ON
position and
then set the
INTERNAL POWER
circuit breaker to its ON posi-
tion.
(The SWITCHED l20V OUTLETS circuit breaker can be
set
to its ON position at this time if desired although it is not
necessary until
power is required for the two associated
AC
power receptacles loca ted on the
Power Control Module.
(The
two standard AC
receptacles are for the system mag tape unit
and disc dr ive .)
11-18