Siemens SINUMERIK 840DE sl Commissioning Manual page 492

Basesoftware and operating software
Hide thumbs Also See for SINUMERIK 840DE sl:
Table of Contents

Advertisement

Service and diagnostics
18.13 PROFIBUS/PROFINET and AS-i bus diagnostics
18.13.3
Configuring the AS-i bus
You obtain a fast overview of the existing AS-Interface network using the AS-Interface (AS-i)
diagnostics. Permanent monitoring and an error search function provide you with the following
information:
● Status flags acc. to the AS-i specification
● States of the AS-i slaves
Precondition
● For AS-i diagnostics, it is absolutely necessary to use the FB_SL_COM PLC block from the
HMI PRO block library.
● The configuration file "sltlprodiaghmi.ini" must be available.
AS-i components
The following AS-i components are supported:
CP142-2
CP343-2
DP/AS-i link
DP/AS-i link 20E
DP-AS-i link Advanced
Diagnostic information
All of the AS-i components to be diagnosed must be parameterized in the "sltlprodiaghmi.ini"
configuration file.
Entry
[SKO]
478
4.
Press the "Available devices" softkey to display the diagnostics data
of the available modules.
- OR -
Press the "Suppressed devices" softkey to display the diagnostics
data of the suppressed modules.
- OR -
Press the "Failed devices" softkey to display the diagnostics data of
the failed modules.
- OR -
Press the "Faulty devices" softkey to display the diagnostics data of
the faulty modules.
(Type ID 1)
(Type ID 2)
(Type ID 3)
(Type ID 4)
(Type ID 6)
ComboCount=x
Description
Number of entries (x) in the selection list
Commissioning Manual, 12/2017, 6FC5397-1DP40-6BA1
SINUMERIK Operate (IM9)