Minimum Gage For Cord - Makita 9924DB Instruction Manual

76 mm (3”)
Hide thumbs Also See for 9924DB:
Table of Contents

Advertisement

24. When servicing a tool, use only identical
replacement parts. Follow instructions in
the Maintenance section of this manual.
USE PROPER EXTENSION CORD: Make sure your extension cord is in good condition.
When using an extension cord, be sure to use one heavy enough to carry the current your
product will draw. An undersized cord will cause a drop in line voltage resulting in loss of
power and overheating. Table 1 shows the correct size to use depending on cord length and
nameplate ampere rating. If in doubt, use the next heavier gage. The smaller the gage num-
ber, the heavier the cord.
Ampere Rating
More Than
0
6
10
12
4
Table 1: Minimum gage for cord
Not More Than
6
10
12
16
Use of unauthorized parts or failure to follow
Maintenance instructions may create a risk of
electric shock or injury.
Volts
Total length of cord in feet
120 V
25 ft.
18
18
16
14
50 ft.
100 ft.
AWG
16
16
16
14
16
14
12
Not Recommended
150 ft.
14
12
12