Customer Information; Product Specifications - Maytag PerformaHJ6301JRT2 User Manual

Table of Contents

Advertisement

Customer Information
Thank You
for purchasing a Maytag water heater.
• The installation must conform with the instructions in this
Properly installed and maintained, it should give you years of
manual; electric company rules; and Local Codes, or in the
absence of Local Codes, with the latest edition of the
trouble free service. It is strongly suggested that this new
water heater be professionally installed, call Maytag Customer
National Electrical Code. This publication is available from
Service at 1-800-788-8899
for recommended installers,
your local government or public library or electric company
or by writing Underwriters
Laboratories Inc., 333 Pfingsten
Abbreviations
Found
In This
Instruction
Manual
Road, Northbrook, IL 60062.
U.L.- Underwriters Laboratories Inc., 333 Ptingsten Rd.,
• If after reading this manual you have any questions or do
Northbrook, IL 60062
not understand any portion of the instructions, call Maytag
National Electrical Code-This pubhcation is ava//able from
Customer Service at 1-800-788-8899
for an authorized
your local government or public library or electric company or
servicer.
by writing to U.L. above.
ANSI-American
National Standards Institute
• Carefi_lly plan the place where you are going to put the
water heater. Correct electrical wiring and connections are
• Read the "Safety Instructions" section, pages 2 and 3 of this
very important in preventing death from possible electrical
manual first and then the entire manual carefully. If you
shock and tires.
don't follow the safety rules, the water heater will not oper-
Examine the location to ensure the water heater complies
ate properly. It could cause DEATH,
SERIOUS BODILY
with the "Locating the New Water Heater" section.
INJURY AND/OR
PROPERTY
DAMAGE.
This manual contains instructions for the installation, oper-
• For California installation this water heater must be braced,
ation, and maintenance of this electric water heater. It also
anchored, or strapped to avoid falling or moving during an
contains warnings throughout the manual that you must
earthquake. See instructions for correct installation proce-
read and be aware of. All warnings and all instructions are
dures. Instructions may be obtained from the California
essential to the proper operation of the water heater and
office of the State Architect, 400 P Street, Sacramento, CA
your safety. Since we cannot put everything on the first few
95814.
pages, READ THIS ENTIRE MANUAL
BEFORE
ATTEMPTING
TO INSTALL OR OPERATE
THE
• Massachusetts Code requires this water heater to be
installed in accordance with Massachusetts 248-CMR 2.00:
WATER HEATER.
State Plumbing Code and 248-CMR
5.00.
Product Specifications
Model
HJ6301JRT2
HJ6302JRT2
HJ6301JLS
HJ6302JLS
HJ6401JRT2
HJ6401JRT2F
Tank Capacity
In Gal.
30
30
30
30
40
•Element
Upper
--
4500
--
4500
--
Wattage
at 240 Volt
Lower
4500
4500
4500
4500
4500
Recovery Rate
Upper
--
20
--
20
--
In Gals Per Hr.
@ 90*F Rise
Lower
20
20
20
20
20
Diameter
18"
18"
22"
22"
18"
Height
46"
46"
293/,"
293/4"
591/2 "
Maximum Fuse or
Circuit Breaker Size
30
30
30
30
30
Minimum
Wire Size (Gauge)
10
10
10
10
10
• Standard dement wattages are shown. Other element wattages (up to the maximum shown) are availablewhen specified.
•Wiring size basedon standard60"C copperwire.If distance from fuse box to water heater is more than 90 feet, referto your
local electrical code.
5