Service and Maintenance (cont'd)
Thermostat
Adjustments
Temperature-Pressure
Relief
Valve Operation
The upper and/or lower thermostat(s) have been factory set at
hot (approximately 120°F) to reduce the risk of scald injury.
The temperature-pressure
relief valve must be manually oper-
The upperand/or lowerthermostat(s)are adjustable if a dif-
ated at leastoncea year.
ferent water temperature is desired. Read all waxnings in the
"Temperature Regulation" section before proceeding.
/TEMPERATURE-PRESSURE
/
RELIEF V ALVE
NOTE:
It is not necessary to adjust the upper thermostat.
_smm_
A
However, flit is adjusted above the factory set point of
120°F (HOT)
it is recommended that it not be set higher
than the lower thermostat
setting.
To adjust the temperature setting for both upper and lower
DISCHARGE PIPE
thermostats, proceed as follows:
1. Turn "OFF" the electric power to the water heater at the
junction box.
AWARNING
The temperature-pressure
relief
valve
must be
manually
operatedat
least once a year. Caution
AWARNING
should be taken to ensure that (1) no one is in front
HAZARD OF ELECTRICAL SHOCK! Before removing
of or around the outlet of the temperature-pres-
any access panels or servicing the water
heater,
sure relief valve discharge line, and (2) the water
make sure the electrical supply to the water heater
manually
discharged will not cause any property
is turned "OFF". Failure to do this could result in
damage
or bodily
injury.
The water
may be
DEATH, SERIOUS BODILY INJURY, OR PROPERTY
extremely hot.
DAMAGE.
If after
manually
operating
the valve, it fails to
completely
reset and continues to release water,
immediately
close the cold water inlet to the water
2. Take "OFF" the access panel,
heater,
follow
the draining
instructions,
and
replace the temperature-pressure
relief valve with
a new one.
3. The slotted adjustment (using a screwdriver) can be turned
clockwise (f'-_
to increase the temperature
setting or
counter clockwise
(¢_'x)
to decrease the temperature
Failure to install and maintain a new properly listed tempera-
setting,
ture-pressure relief valve will release the manufacturer from
any claim which might result from excessive temperature or
4. Replace the access panel,
pressure.
5. Turn "ON" the power supply.
AWARNING
If the temperature-pressure
relief
valve
on the
appliance
weeps
or discharges
periodically,
this
may be due to thermal
expansion.
Your water
heater
may have a check valve installed
in the
water line or a water meter with a check valve. Call
Mayta_
Customer Service at 1-800-788-8899
for an
authorized
servicer. Do not plug the temperature-
)ressure relief valve.