Safety Instructions
AWARNING
AWARNING
Improper installation, adjustment, alteration, service
At the time of manufacture this water heater was pro-
or maintenance
can cause DEATH, SERIOUS BODILY
vided with a combination temperature-pressures relief
INJURY, OR PROPERTY DAMAGE. Refer to this manu-
valve certified by a nationally recognized testing labo-
al for assistance consult your local utility
or call
ratory that maintains periodic inspection of production
Maytag Customer Service at 1-800-788-8899
for an
of listed equipment
or materials,
as meeting the
authorized servicer for further information,
requirements for Relief Valves and Automatic
Gas
Shutoff Devices for Hot Water Supply Systems, and
the latest edition of ANSI Z21.22 and the code require-
ments of ASME. If replaced, the valve must meet the
A, WARNING
mquiremeuts of local cedes, but not lessthan a combi-
nation temperature and pressure relief valve certified
HAZARD OF ELECTRICAL SHOCK! Before removing
as meeting the requirements for Relief Valves and
any access panels or servicing
the water
heater,
Automatic Gas Shutoff Devices for Hot Water Supply
make sure the electrical supply to the water heater
Systems, ANSI 7.21.22 by a nationally recognized test-
is turned "OFF". Failure to do this could result in
ing laboratory that maintains periodic inspection of
DEATH, SERIOUS BODILY INJURY, OR PROPERTY
production of listad equipment or materials.
DAMAGE.
The valve must be marked with a maximum set pres-
sure not to exceed the marked hydrostatic working
pressure of the water heater (150 Ibs./sq. in.) and a
discharge capacity not less than the water
heater
input rate as shown
on the model rating
plate.
A'WARNING
(Electric heaters - watts divided by 1000 x 3415 equal
HOTTER WATER CAN SCALD: Water
heaters
are
BTU/Hr. rate.)
intended to produce hot water. Water heated to a
Your local jurisdictional authority, while mandating the
temperature
which will satisfy clothes washing,
use of a temperature-pressure
relief valve complying
dish washing, and other sanitizing needs can scald
with ANSI Z21.22 and ASME, may require a valve model
different from the one fum shed with the water heater.
and permanently
injure you upon contact.
Some
people are more likely to be permanently injured by
Compliance with such local requirements must be sat-
hot water
than others. These include the elderly,
isfied by the installer or end user of the water heater
children, the infirm, or physically/mentally
handi-
with a locally prescribed temperature-pressure
relief
capped. If anyone using hot water in your home fits
valve installed In the designated opening in the water
into one of these groups or if there is a local code or
heater in place of the factory furnished valve.
state law requiring a certain temperature
water at
For safe operation of the water heater, the relief valve
must not be removed from it's designated opening or
the hot water tap, then you must take special pre-
cautions. In addition to using the lowest possible
plugged.
temperature
setting that satisfies your hot water
The temperature-pressure
relief
valve
must be
needs, a means such as a mixing valve, should be
installed directly into the fitting of the water heater
used at the hot water taps used by these people or
designated
for the relief valve. Position the valve
at the water heater. Mixing valves are available at
downward and provide tubing so that any discharge
plumbing supply or hardware stores. Follow manu-
will exit only within 6 inches above, or at any distance
tacturers
instructions for installation
of the valves,
below the structural floor. Be certain that no contact is
Before changing the factory setting on the thermo-
made with any live electrical part. The discharge open-
stat, read the "Temperature
Regulation"
section in
ing must not be blocked or reduced in size under any
this manual,
circumstances. Excessivelength, over 30 feet, or use of
more than four elbows can cause restriction
and
reduce the discharge capacity of the valve.
No valve or other obstruction is to be placed between
the relief valve and the tank. Do not connect tubing
AWARNING
directly to discharge drain unless a 6" air gap is provid-
INSULATING JACKETS: When installing an external
ed. To prevent bodily injury, hazard to life, or property
water heater insulation jacket on an electric water
damage, the relief valve must be allowed to discharge
heater:
water in quantities should circumstances demand. If
• DO NOT cover the temperature-pressure relief valve,
the discharge pipe is not connected to a drain or other
• DO NOT put insulation over the access covers or
suitable means, the water flow may cause property
any access areas,
damage.
• DO NOT cover or remove operating instructions,
The Discharge Pipe:
and safety related warning
labels and materials
Must not be smaller in size than the outlet pipe size
affixed to the water heater,
of the valve, or have any reducing couplings or
other restrictions.
Must not be plugged or blocked.
Must be of material listed for hot water distribution.
•,WARNING
Must be installed so as to allow complete drainage
of both the temperature-pressure
relief valve, and
Do not use this appliance if any part of it has been
the discharge pipe.
under water. An electrical short or malfunction could
Must terminate at an adequate drain.
occur. The water heater shou d be rep aced.
Must not have any valve between the relief valve
and tank.