10.3 Restoration Procedure 2 (With No Backup Copy)
10.3.1
Overview
After replacing the I/O board, start the Off-line Maintenance Utility, and enter the product
information and chassis information in manual mode to update values. The RMC data (remote
management data) must be restored in manual mode by the remote management feature of the OS.
10.3.2
Requirement
EXPRESSBUILDER CD-ROM
10.3.3
Details
1. Start EXPRESSBUILDER, and select [Tool] → [Off-line Maintenance Utility].
2. Select [System Information Management]. The window shown below appears.
System Information Management
Save
Save RMC Data
Administrator Menu
Return to the previous menu
3. Select [Administrator Menu]. The messages shown below appear.
Administrator Menu
Attention!
Do not use the Administrator Menu except the maintenance staffs.
Do you want to use the menu?
Yes:[Enter] No:[ESC]
4. Press Enter. The messages shown below appear.
Administrator Menu
A password is necessary to use the Administrator Menu.
Input the Maintenance Staff's password.
Password->
Press the ESC key to exit.
-
-
154