Appendix H Storage Migration Setting Files
H.1 Template File for Storage Migration Settings
GROUP
PATH
GROUP
VOL
Keyword
Specify the path information of the destination
and source storage systems.
Up to 8 paths per path group can be specified.
[Example]
•
For the ETERNUS DX8700 S3/DX8900 S3
PATH=CEx,CMy,CAz,Pw,vvvvvvvvvvvvvvvv
•
For the other models
PATH=CMy,CAz,Pw,vvvvvvvvvvvvvvvv
x: CE number, y: CM number, z: CA number,
w: Port number
vvvvvvvvvvvvvvvv: WWN
CE
Specify the location information (CEx,
CMy, CAz, Pw) of the destination FC-
CM
Initiator port to which the path is
CA
configured.
P
WWN
Specify the World Wide Name (WWN) of
the source FC-Initiator port to which the
path is configured.
Specify the source LUN (Y) and the destination
volume (Z).
The maximum number of source LUNs for each
migration path (PATH) is 512.
[Example] VOL=Y, Z
Example of specifying source LUNs and
destination volumes
Source LUN
Destination volume
Input a decimal number
Input a decimal number
Specification method: "0x"
Specification method:
is not added on top of the
"0x" is not added on top of
value.
the value.
Decimal numbers can be
used only when the source
LUN is from "0" to "255".
Input a hexadecimal number
Input a hexadecimal number
(4-digit)
(4-digit)
Specification method:
Specification method:
Add "0x" on top of the value.
Add "0x" on top of the value.
Input in "0xYYYY" format.
Input in "0xZZZZ" format.
Input a hexadecimal number
(16-digit)
Specification method:
Add "0x" on top of the value.
Input in
"0xYYYYYYYYYYYYYYYY"
format.
1075
ETERNUS Web GUI User's Guide (Settings)
Copyright 2015 FUJITSU LIMITED
Number of
Allowed input
settings
4
–
•
For the ETERNUS
DX8700 S3/DX8900 S3
CEx, CMy, CAz, Pw
•
For the other models
CMy, CAz, Pw
x: CE number
y: CM number
z: CA number
w: Port number
16-digit hexadecimal
Source LUN:
0 - 255
(decimal)
0xYYYY
(4-digit hexadecimal)
0xYYYYYYYYYYYYYYYY
(16-digit hexadecimal)
Destination volume:
Z (decimal)
0xZZZZ
(4-digit hexadecimal)
P2X0-1270-13ENZ0