Philips SAVVY VOGUE Service Manual page 15

Cellular phone philips savvy vogue dual band
Hide thumbs Also See for SAVVY VOGUE:
Table of Contents

Advertisement

Philips Consumer Communications
CUSTOMER SERVICES
Author
: Fabrice Tant
Approval : Jean Pierre Hollande
Operational Manager
FER at –102dbm
8.2.7
PCN Specification (1800 Mhz)
Test Parameters
EMISSION
Phase error RMS
Phase error Peak
Frequency Error
Power Ramping
Modulation
Switching Transcients
Power reading
Output Power
RECEPTION
Rx level
Rx Qual
Rx Level
Rx Qual
Rx Level
Rx Qual
TCH LOOP
SENSITIVITY
BER at -85dbm
FER at -85dbm
BER at –102dbm
FER at –102dbm
PCC/VY/691/E/TCD188LVL2/0026/TF/MLD
SERVICE REPAIR SUPPORT
PROCEDURE
1, 62, 124
Channel
512, 635, 760, 885
512, 635, 760, 885
512, 635, 760, 885
512, 635, 760, 885
PHILIPS
PCC/VY/691/E/TCD188LVL2/0026/TF/MLD
Creation
Date : 26/06/2000
Page : 15 of 30
0%
Level
Standard
Specification
0, 5, 10
0 to 5.0 degree
0, 5, 10
-20 to +20 degree
0, 5, 10
-180 Hz to + 180 Hz
0, 5, 10
Mask
0, 5, 10
Mask
0, 5, 10
Mask
Level 15
0 +/- 5.0 dBm
Level 10
10 +/- 4.0 dBm
Level 5
20 +/- 3.0 dBm
Level 0
30 +/- 2.0 dBm
-100dbm
8 to 13
-100dbm
0 to 1
-80dbm
28 to 33
-80dbm
0 to 1
-60dbm
48 to 53
-60dbm
0 to 1
2.44%
0%
0%
0%