CUSTOMER SERVICES
Author
: Fabrice Tant
Approval : Jean Pierre Hollande
Operational Manager
All the NFF products must be directly returned to the customer.

8.2 RF Test

8.2.1
The Test SIM Card "SP" must be inserted in to the phone before starting the test.
8.2.2
Set the equipment as shown in picture chapter 6.2
The RF cable to use is made by AMP (Part No.: 941-555-1)
8.2.3
Set in the offset field of the radio tester a - 0.3dBm lose for GSM Tests and a - 0.5dBm lose
for PCN tests.
8.2.4
The followings operations must be done:
8.2.5
The followings parameters must be checked in TCH loop mode:
Emission parameters
Reception parameters
Generally the test sequences built-in the testers will be used to check the mobile. You must
assess that the test sequences limits comply with the standard specifications.
PCC/VY/691/E/TCD188LVL2/0026/TF/MLD
SERVICE REPAIR SUPPORT
PROCEDURE
-
Synchronization/Registration
-
Call set up from the mobile
-
Voice loopback (check sound quality)
-
Call release
-
Call set up from tester
-
Call release from tester
-
Power level
-
RMS phase error
-
Peak phase error
-
Frequency error
-
Power ramping
-
Rx level
-
Rx quality
-
BER (Byte Error Rate)
-
FER (Frequency Error Rate)