Jams At Small Original Reverse Section - Toshiba e-STUDIO520 Service Manual

Multifunctional digital systems
Hide thumbs Also See for e-STUDIO520:
Table of Contents

Advertisement

3) Original jammed not reaching the large original exit sensor (S68) (while registering the back side) :
E733
-
Jam detection
This jam is detected during the time after the back side registration or transportation to the 1st
roller starts until an original reaches the large original exit sensor (S68).
-
Jam pulse setting
The setting value for the jam pulse is the equivalent number of pulses it takes for an original to
proceed the distance from the large original exit roller to the large original exit sensor (S68) plus
60 mm.
16.6.4

Jams at small original reverse section

1) Original jammed not reaching the small original reverse sensor (S66) (to the small original reverse
side) : E723
-
Jam detection
This jam is detected during the time after an original reaches the intermediate transport roller
until it reaches the small original reverse sensor (S66).
-
Jam pulse setting
The setting value of the jam pulse is equivalent number of pulses it takes for an original to pro-
ceed the distance from the intermediate transport roller to the small original reverse sensor (S66)
plus 60 mm.
2) Original jammed at the small original reverse sensor (S66) (to the small original reverse side) : E741
-
Jam detection
This jam is detected during the time after the deceleration, which is set to finish at the position 20
mm short of the small original reverse sensor (S66), starts until an original passes through the
small original reverse sensor (S66).
-
Jam timer setting
The setting value for the jam timer is the time mentioned above plus necessary time for an origi-
nal to proceed 60 mm.
3) Original jammed not reaching the small original reverse sensor (S66) (from the small original
reverse side to the small original exit side) : E742
-
Jam detection
This jam is detected during the time after discharging starts at the small original reverse section
until an original reaches the small original reverse sensor (S66).
-
Jam timer setting
The setting value for the jam timer is three times as much time as mentioned above.
4) Original jammed at the small original exit sensor (S67) (from the small original reverse side to the
small original exit side) : E741
-
Jam detection
This jam is detected during the time after an original reaches the small original exit sensor (S66)
until it passes through the small original reverse sensor.
-
Jam timer setting
The setting value for the jam timer is 1.5 times as much time as it takes for an LT, which is the
longest original (of all kinds of small-sized paper) when discharging small originals, to pass
through the small original reverse sensor (S66).
March 2005 © TOSHIBA TEC