  • Page 1 AMAX 2100 / 3000 / 4000 User Guide...
  • Page 3: Table Of Contents

    Event Log Recall Mode 12.1 How to Select All Event Log Recall Mode 12.2 How to Select EN Event Log Recall Mode 12.3 How to Select Dialer Event Log Recall Mode Bosch Sicherheitsysteme GmbH User Guide 2014.09 | 03 | F.01U.295.569...
  • Page 4 AMAX Faults and Tamper Conditions 13.1 System Fault or Tamper Analysis Mode via Text Keypad 13.2 System Fault or Tamper Analysis Mode via LED/LCD Keypad Resetting the Control Panel Troubleshooting 2014.09 | 03 | F.01U.295.569 User Guide Bosch Sicherheitsysteme GmbH...
  • Page 5: Safety

    – Always handle the system carefully. – Never open or modify the system. – Please contact your installer if you want to get your system modified. Bosch Sicherheitsysteme GmbH User Guide 2014.09 | 03 | F.01U.295.569...
  • Page 6: Short Information

    Installation Guide. Information on the main steps required for basic system installation and setup can be found in the Quick Start Guide. 2014.09 | 03 | F.01U.295.569 User Guide Bosch Sicherheitsysteme GmbH...
  • Page 7: Keypads

    The following text keypad can be used for operating AMAX panel 2100/3000/4000. IUI-AMAX4-TEXT The following LED/LCD keypads can be used for operating AMAX panel 2100/3000/4000. IUI-AMAX3-LED8 IUI-AMAX3-LED16 IUI-AMAX-LED8 IUI-AMAX-LCD8 Notice! Only a text keypad can be used as a master keypad. Bosch Sicherheitsysteme GmbH User Guide 2014.09 | 03 | F.01U.295.569...
  • Page 8: Keypad Indicators

    AC main power supply failed. MAINS second lights off) System fault or Tamper condition is present. System is in normal status. FAULTS Flashes System fault or tamper condition must be acknowledged. System is disarmed. 2014.09 | 03 | F.01U.295.569 User Guide Bosch Sicherheitsysteme GmbH...
  • Page 9 Continuous 0.5 second beep, stops – Entry delay time (until alarm ends or system is for 0.5 seconds disarmed) – Exit delay time (stops 10 seconds before exit delay stops) Bosch Sicherheitsysteme GmbH User Guide 2014.09 | 03 | F.01U.295.569...
  • Page 10: Quick Keypad Operations Instructions

    Macros Record Macro 1 [code] + [8] [1] + [#] + operation + [#] √ √ √ √ for 3 sec. 2014.09 | 03 | F.01U.295.569 User Guide Bosch Sicherheitsysteme GmbH...
  • Page 11 √ √ √ Change Language [code] + [5] [8] + [#] + [2-digit no. for √ √ √ available languages] + [#] 01=EN; 02=DE; 03=ES; 04=FR ; 05=PT; 06=PL; 07=NL; 08=SE Bosch Sicherheitsysteme GmbH User Guide 2014.09 | 03 | F.01U.295.569...
  • Page 12 M1 = Master User 1 M2 = Master User 2 IN = Installer * This function can be enabled/disabled individually for every user. For further information, please refer to Add/Change User Codes, page 24. 2014.09 | 03 | F.01U.295.569 User Guide Bosch Sicherheitsysteme GmbH...
  • Page 13: User Menu

    ADD/CHG USER CODE CHANGE INDIV CODE INITIATE CALL BACK CHANGE LANGUAGE MACRO START INPUT MACRO No 1-3 RECORD :END # 3s START PLAY SCHEDULE ENABLE INSTALLER ACCESS ENABLE INSTALLER DISABLE INSTALLER Bosch Sicherheitsysteme GmbH User Guide 2014.09 | 03 | F.01U.295.569...
  • Page 14: Arming And Disarming The System

    Users can use a key switch to arm the system. Activate the key switch. The AWAY indicator flashes slowly and exit time starts. After exit time, the AWAY indicator is lit. Please contact your installer to enable/disable this function. 2014.09 | 03 | F.01U.295.569 User Guide Bosch Sicherheitsysteme GmbH...
  • Page 15: Arming In Stay Mode

    AWAY mode, then forced arming is not permitted. In this case, you have to seal all zones or manually isolate them before you can arm the system. Please contact your installer to enable/disable this function. Bosch Sicherheitsysteme GmbH User Guide 2014.09 | 03 | F.01U.295.569...
  • Page 16: Arming With A Master Keypad

    The STAY indicator flashes slowly and exit time starts. After the exit time, the STAY indicator is lit and the selected area is displayed as armed. Repeat step 1 if you want to arm multiple areas. 2014.09 | 03 | F.01U.295.569 User Guide Bosch Sicherheitsysteme GmbH...
  • Page 17: Disarming The System

    Enter your code and the two-digit number of the area you want to disarm. Press [#]. The system beeps twice and the AWAY or STAY indicator is extinguished. The selected area is disarmed. Repeat step 1 if you want to disarm multiple areas. Bosch Sicherheitsysteme GmbH User Guide 2014.09 | 03 | F.01U.295.569...
  • Page 18: Changing The Menu Language

    Enter your code + [5] [8] and press [#]. The available menu languages are displayed. Enter the two-digit number for the desired language. Press [#]. The system beeps twice and the menu language is changed. 2014.09 | 03 | F.01U.295.569 User Guide Bosch Sicherheitsysteme GmbH...
  • Page 19: System Test

    Unseal and seal the zones to be tested. The system beeps. The siren beeps once each time a zone status is changed. How to Exit Walk Test Mode: Enter your code + [4] [3] and press [#]. Bosch Sicherheitsysteme GmbH User Guide 2014.09 | 03 | F.01U.295.569...
  • Page 20: Bypassing

    Only zone tampers can not be bypassed. How to bypass a Fault or Tamper Condition Enter your code + [3] [4] and press [#]. The system beeps twice and fault or tamper conditions are bypassed. 2014.09 | 03 | F.01U.295.569 User Guide Bosch Sicherheitsysteme GmbH...
  • Page 21: Schedules

    Enter the two-digit schedule number you wish to activate/deactivate. The selected schedule is checked/unchecked. Repeat step 6 if you want to activate/deactivate multiple schedules. Press [#]. Press [-] twice to exit. Bosch Sicherheitsysteme GmbH User Guide 2014.09 | 03 | F.01U.295.569...
  • Page 22: Macros

    Press [#] to exit the bypass menu. Press [#] for three seconds to exit the record macros menu. The system beeps twice. The macro 1 for bypassing zone 3 is recorded. Zone 3 is bypassed. 2014.09 | 03 | F.01U.295.569 User Guide Bosch Sicherheitsysteme GmbH...
  • Page 23: Playing Macros

    The system beeps and the macro 1 is executed automatically. If zone 3 was unbypassed before playing macro 1, it is bypassed now. If zone 3 was bypassed before playing macro 1, it is unbypassed now. Bosch Sicherheitsysteme GmbH User Guide 2014.09 | 03 | F.01U.295.569...
  • Page 24: Codes

    13. Press [#]. 14. Optionally enter a keyfob ID manually. Press and hold [*] for three seconds to switch to the KEYFOB ID: AUTO menu. Trigger the keyfob to give alarm once. 2014.09 | 03 | F.01U.295.569 User Guide Bosch Sicherheitsysteme GmbH...
  • Page 25: Change Individual Code

    Enter a new code with a default length of four digits. (A code with five or six digits is also possible but has to be enabled by the installer.) Press [#]. The system beeps twice and the STAY and AWAY indicators stop flashing. The user code is changed. Bosch Sicherheitsysteme GmbH User Guide 2014.09 | 03 | F.01U.295.569...
  • Page 26: Keypad Alarm Operation Commands

    Please contact your installer to enable/disable this function. 10.3 Keypad Medical Alarm Press and hold [7] + [9] for three seconds. A silent keypad medical alarm is transmitted. Please contact your installer to enable/disable this function. 2014.09 | 03 | F.01U.295.569 User Guide Bosch Sicherheitsysteme GmbH...
  • Page 27: Domestic Dialing

    45 seconds if it can not detect the acknowledgement tone and redial later. Press [#] between two acknowledgement tones to confirm the alarm. The system beeps for two seconds and closes the line. Bosch Sicherheitsysteme GmbH User Guide 2014.09 | 03 | F.01U.295.569...
  • Page 28: Event Log Recall Mode

    Enter your code + [2] [4] and press [#]. The system beeps twice and dialer events are displayed. Use [▲] and [▼] to display all dialer event logs. Press [#] to exit. 2014.09 | 03 | F.01U.295.569 User Guide Bosch Sicherheitsysteme GmbH...
  • Page 29: Faults And Tamper Conditions

    Example: 2 – 1, which indicates a panel AC failure. If necessary press [0] to return to step 2. Press [#] to exit. The STAY and AWAY indicators are extinguished and the FAULT indicator is lit. Bosch Sicherheitsysteme GmbH User Guide 2014.09 | 03 | F.01U.295.569...
  • Page 30 1 - 2 Panel Aux power 1 – 2 fault Bosch option bus power failure 1 - 2 Bosch option bus 1 – 2 power fault RF repeater AC power failure 2014.09 | 03 | F.01U.295.569 User Guide Bosch Sicherheitsysteme GmbH...
  • Page 31 1 – 16 Zone type 1 – 16 tamper Keypad Lock out Keypad Lock out RF receiver tamper RF receiver tamper RF repeater tamper 1 – 8 RF repeater tamper Bosch Sicherheitsysteme GmbH User Guide 2014.09 | 03 | F.01U.295.569...
  • Page 32 External failure 1 - 16 External fault zone 1 - 16 Table 13.1: Types of fault or tamper conditions * In case one or more faults occur in this category 2014.09 | 03 | F.01U.295.569 User Guide Bosch Sicherheitsysteme GmbH...
  • Page 33: Resetting The Control Panel

    You can only reset alarms, faults or tamper conditions when they are not active anymore. Enter your code + [6] [#]. The system beeps twice and the signal is eliminated. Bosch Sicherheitsysteme GmbH User Guide 2014.09 | 03 | F.01U.295.569...
  • Page 34: Troubleshooting

    | Troubleshooting AMAX Troubleshooting Please contact your installer in case of problems or any unexpected behavior of the system. 2014.09 | 03 | F.01U.295.569 User Guide Bosch Sicherheitsysteme GmbH...
  • Page 36 Bosch Sicherheitssysteme GmbH Robert-Bosch-Ring 5 85630 Grasbrunn Germany www.boschsecurity.com © Bosch Sicherheitssysteme GmbH, 2014...

This manual is also suitable for:

Amax 3000Amax 4000

Table of Contents