AMAX panel 4000 / AMAX panel 4000 Table of Contents | en Table of contents Graphics Safety Short Information System overview Optional Modules and Peripheral Devices Bosch Option Bus Keypad 5.2.1 General 5.2.2 Address Setting 5.2.3 Wiring 5.2.4 Status Indicator DX2010 5.3.1...
Page 4
Address and Key Programming 7.8.1 Address Programming 7.8.2 Programming with the ICP-EZPK Programming Key Configuration Programming with the Keypad 8.1.1 Text Keypad Menu Programming 8.1.2 LED/LCD Keypad Programming PC Programming 8.2.1 Direct Connection 2014.4 | 01 | F.01U.267.112 Installation Guide Bosch Sicherheitssysteme GmbH...
Page 5
Communication and Reports Setting Zone Programming Output Programming Access Codes System Programming Troubleshooting 10.1 General Trouble 10.2 Trouble Fault Inquiry Maintenance 11.1 Firmware Upgrade with the ICP-EZRU2 Upgrade Key Technical Data Bosch Sicherheitssysteme GmbH Installation Guide 2014.4 | 01 | F.01U.267.112...
- The system / product must be installed and maintained by qualified installer / service person. - Bosch recommends testing the alarm system at least once a week. Danger! As static-sensitive components are included in PCBs, anti-static steps should be followed and they should be carefully installed.
Each AMAX panel can be tailored to meet your requirements quickly and easily. The programming simplicity makes your installation quick, accurate, and rewarding. Bosch Sicherheitssysteme GmbH Installation Guide 2014.4 | 01 | F.01U.267.112...
Figure 4.1: AMAX 2100/3000 Overview Radion LCD / LED Keypad Text Keypad DX2010 Option Bus B426 DX4020G DX3010 PSTN GSM/ GPRS Video A Link Plus Figure 4.2: AMAX 4000 Overview 2014.4 | 01 | F.01U.267.112 Installation Guide Bosch Sicherheitssysteme GmbH...
The AMAX panel provides the Bosch Option Bus to attach expansion modules. AMAX 2100 / 3000 each has one (Bosch Option Bus 1) and AMAX 4000 has two (Bosch Option Bus 1 and Maximum 14 modules (8 keypads) can be connected to each bus. The total length of the cable for connection of all keypads and expansion modules wired to one Bosch Option Bus must not exceed 700m.
Jumper short-circuited (both metal pins are covered) Table 5.3: Keypad Jumper Settings 5.2.3 Wiring Connect the keypad to Bosch Option Bus of AMAX panel according to the following figure. The last keypad must be placed within a cable distance of 200m. AMAX 2100 / 3000 Keypad AMAX 4000 Figure 5.2: Connecting keypad to the AMAX Panel...
When data bus address is changed, the module needs to be re-powered to make the new address effective. 5.3.3 Wiring Do not use twisted pair or shielded cables to connect DX2010 and the AMAX panel. 2014.4 | 01 | F.01U.267.112 Installation Guide Bosch Sicherheitssysteme GmbH...
For more information about installation, see DX3010 Installation Guide. See also – Module Installation, page 23 5.4.2 Address Setting Each DX3010 module connected to the AMAX panel must have its own data bus address. Bosch Sicherheitssysteme GmbH Installation Guide 2014.4 | 01 | F.01U.267.112...
9, i.e., set the address to 250 when the second B426 is used. 5.5.3 Wiring Connect B426 to Bosch option Bus 1 or 2. The cable may not exceed 150 meters. AMAX 2100 / 3000 B426 AMAX 4000 Figure 5.7: Connecting B426 to the AMAX Panel...
The connection of ITS-DX4020-G and the AMAX panel is divided into two modes: GPRS and GSM. AMAX 2100 / 3000 DX4020G AMAX 4000 Figure 5.8: GPRS Mode in Support of IP 2014.4 | 01 | F.01U.267.112 Installation Guide Bosch Sicherheitssysteme GmbH...
Reception distances are generally improved with higher mounting locations and with no metal objects near the antennas. 5.7.2 Address Setting Set receiver address to #1. The AMAX panel supports only receiver 1, not receiver 2. Bosch Sicherheitssysteme GmbH Installation Guide 2014.4 | 01 | F.01U.267.112...
Figure 5.10: Address 5.7.3 Wiring Connect the RF3227E receiver to Bosch option Bus. The cable must not exceed 300 m. Adding additional devices to the bus might reduce the maximum distance. Shielded cable is not required. Do not use twisted pair wires.
Address Setting Set rotary switch to value 1. The AMAX panel supports one receiver only. 5.8.3 Wiring Connect the RADION receiver to bosch option bus. The cable distance to the AMAX panel may not exceed 300 meters. 5.8.4 Status Indicator...
Page 22
– A communication failure between the AMAX panel and the of the 3rd pulse receiver or – An invalid address switch setting. Table 5.13: RFRC-OPT Radion Receiver System Status Indicator 2014.4 | 01 | F.01U.267.112 Installation Guide Bosch Sicherheitssysteme GmbH...
Please choose appropriate positioning screw kit when you have to install in a non-load bearing wall. E N √ E N √ Enclosure - Standard Enclosure with mounting plate Figure 6.1: Enclosure / with mounting plate Bosch Sicherheitssysteme GmbH Installation Guide 2014.4 | 01 | F.01U.267.112...
Connect one end of the red wire to the "BATT +" port of the AMAX panel, the other end to the positive (+) pole of the battery. Once the installation is complete, the AMAX panel will begin to charge the battery. 2014.4 | 01 | F.01U.267.112 Installation Guide Bosch Sicherheitssysteme GmbH...
The AMAX panel indicates the system status by using the LED status indicator on the system main board. Slow flash of red on status indicator (repeating on and off with an interval of 1 second) indicates normal system operation. Bosch Sicherheitssysteme GmbH Installation Guide 2014.4 | 01 | F.01U.267.112...
To realize EN conform Access to the Monitored Area, one of the following methods must be used – Opening a door (to the entry / exit route) must start the entry procedure – Indication of arm / disarm Status 2014.4 | 01 | F.01U.267.112 Installation Guide Bosch Sicherheitssysteme GmbH...
Page 27
When the panel is set without EN parameters, the EN Indication (on Label) must be removed – Maximum of 10 Devices shall be connected to one Zone Input (Panel, Keypad, Input Module, RFUN,…) Bosch Sicherheitssysteme GmbH Installation Guide 2014.4 | 01 | F.01U.267.112...
O ption 3: G rade 2 (European EN standards) + RTC Certification Number: 1223400001A0 Prerequisites for an NFa2p conform Installation - When aNFa2p conform instalation is made, the environmental class of the Panel is "1” 6.5.3 INCERT - AMAX 4000 2014.4 | 01 | F.01U.267.112 Installation Guide Bosch Sicherheitssysteme GmbH...
Example You can set up Dialer 1 to report to receiver 1 in Bosch Network (Conettix) Format and set up Dialer 2, Dialer 3, and Dialer 4 to report to a receiver of a central monitoring station in Contact ID Format only, if Dialer 1 is unsuccessful.
Page 31
If Contact ID or SIA format is selected, the information is transmitted by telephone line; if Bosch Network is selected, then it is connected with B426 / DX4020 or ITS-DX4020G GPRS. Transmission format is defaulted as Contact ID.
Page 32
AMAX panel supports SIA Format. SIA allows transmitting System ID, event code, zone ID, area ID, event time, and also event text. Conettix IP Format AMAX panel supports Conettix IP. AMAX panel with DX4020G and B426 are able to connect to Bosch Receivers 6600/6100 using Conettix IP Format. Event Description Dialer Event...
Page 35
When no callback from the receiver after the acknowledge time is reached, the AMAX panel takes it as an unsuccessful communication and makes another attempt. The time ranges from 5 to 99 sec. Bosch Sicherheitssysteme GmbH Installation Guide 2014.4 | 01 | F.01U.267.112...
Display of faults When multiple reports are queued for delivery, the communication path fault is displayed as a logic or relationship. Example: 2014.4 | 01 | F.01U.267.112 Installation Guide Bosch Sicherheitssysteme GmbH...
Page 37
When the failed (internal) delay zone, (internal) instant zone and (internal) follow zone are disarmed, the fault recovery event will occur even if the zone is still in triggering status Bosch Sicherheitssysteme GmbH Installation Guide 2014.4 | 01 | F.01U.267.112...
Page 38
– Keypad Fault: When fault occurs between the keypad and the AMAX panel, the report will be sent. After the fault is recovered, the recovery report will be sent 2014.4 | 01 | F.01U.267.112 Installation Guide Bosch Sicherheitssysteme GmbH...
Page 39
Keypad Fire Alarm Reporting If you press and hold both 4 and 6 for 3 seconds, the fire alarm report will be sent. The fire alarm report has no corresponding alarm recovery report. Bosch Sicherheitssysteme GmbH Installation Guide 2014.4 | 01 | F.01U.267.112...
Only when IP module 1 is used and set to paths 1 to 4, the report can be sent to those paths. 7.1.5 Remote Access The AMAX panel supports remote programming via USB, telephone or IP network using software A -Link Plus. – uploading / downloading programming parameters 2014.4 | 01 | F.01U.267.112 Installation Guide Bosch Sicherheitssysteme GmbH...
The user presses [#] between two acknowledgement tones to confirm the alarming. The acknowledgement tone is the DTMF signal sent by the remote user with the [#]. Bosch Sicherheitssysteme GmbH Installation Guide 2014.4 | 01 | F.01U.267.112...
The installer commands can be used only when all areas of the system are in disarming status with no alarm activated and when installer access is enabled from user. 2014.4 | 01 | F.01U.267.112 Installation Guide Bosch Sicherheitssysteme GmbH...
Page 43
C o p y p ro g r. ke y d a ta to co n tro l p a n e l. [9 ][6 ][3 ] + [# ] √ D is p la y FW ve rs io n [9 ][9 ][9 ] + [# ] √ Figure 7.1: User Code Commands Bosch Sicherheitssysteme GmbH Installation Guide 2014.4 | 01 | F.01U.267.112...
Page 44
User Type Master User Super User Basic User Arming User Duress User 05 -15 No Priority User Code in Area User codes are assigned to one or more areas. Value Area 2014.4 | 01 | F.01U.267.112 Installation Guide Bosch Sicherheitssysteme GmbH...
Instant Interior instant Delay Interior delay Follower Interior follower 24-hour Key-switch toggle Key switch on / off 24-hour panic 24-hour fire 24-hour fire with verification* Tamper Bolt contact External fault Bosch Sicherheitssysteme GmbH Installation Guide 2014.4 | 01 | F.01U.267.112...
Page 48
– When system is disarmed and zone is not restored before, a zone fault restore report is sent 03 - Delay The delay zone will perform as below: 2014.4 | 01 | F.01U.267.112 Installation Guide Bosch Sicherheitssysteme GmbH...
Page 49
07 - 24 Hour The 24 - hour zone will perform as below: Disarm: – Zone normal - no alarm / no report – Zone triggered - alarm / report Bosch Sicherheitssysteme GmbH Installation Guide 2014.4 | 01 | F.01U.267.112...
Page 50
Wiring Diagram for key-switch Zone: short for arm. The momentary time is capable of lasting Minimum 300ms. Zone Wiring Diagram for key-switch Zone: open for arm. The momentary time is capable of lasting Minimum 300ms. Zone 2014.4 | 01 | F.01U.267.112 Installation Guide Bosch Sicherheitssysteme GmbH...
Page 51
AWAY Arm: same as disarm performance STAY Arm: same as disarm performance 14 - Bolt Contact The Bolt-Contact zone will perform as below: Disarm: Bosch Sicherheitssysteme GmbH Installation Guide 2014.4 | 01 | F.01U.267.112...
Page 52
AWAY Arm: same as the delay exit zone AWAY arm status STAY Arm: – This zone will be Ignored and performed as disarm – Refer to Keypad Indicators to see how the zone is displayed during exit time 2014.4 | 01 | F.01U.267.112 Installation Guide Bosch Sicherheitssysteme GmbH...
Page 53
9 – digit RFID using pin keys. When AUTO is selected, trigger RF device in order to enter RFID automatically. Hardwired Input Zones On-board Inputs: The AMAX panel provides onboard hard-wired inputs. An additional input is provided for the enclosure tamper. Bosch Sicherheitssysteme GmbH Installation Guide 2014.4 | 01 | F.01U.267.112...
Page 54
2200 2750 normal 2970 4400 4950 triggered 5220 ∞ tamper Using one 2.2 Kilo resistor as EOL of the tamper zone, which works together with the zone EOL 2.2 Kilo. 2014.4 | 01 | F.01U.267.112 Installation Guide Bosch Sicherheitssysteme GmbH...
Force arm Bypass Silent alarm / Chime Disabled mode Silent alarm Chime mode Zone pulse count Disabled 1-9 pulses Zone lockout Disabled 1 times alarm lockout 3 times alarm lockout Bosch Sicherheitssysteme GmbH Installation Guide 2014.4 | 01 | F.01U.267.112...
Page 56
The zone bypass is valid in one arming period only and will be resumed after disarming. Before disarming, the bypassed zones will ignore all zone triggering and restoration events. The key switch zone cannot be bypassed. 2014.4 | 01 | F.01U.267.112 Installation Guide Bosch Sicherheitssysteme GmbH...
Page 57
The system supports the tamper detection of the zone. This function ensures that the zone is in normal operating status. The process is as follows: If 24-hour zone tamper is enabled, the wiring method for two-terminal resistor is required. Bosch Sicherheitssysteme GmbH Installation Guide 2014.4 | 01 | F.01U.267.112...
Page 58
When the first zone or one of the other zones (with cross zone option) is / are triggered twice or more after cross zone time is expired, the timer restarts 2014.4 | 01 | F.01U.267.112 Installation Guide Bosch Sicherheitssysteme GmbH...
AMAX 2100: In a one area system keypad zone number 17 should be indicated on an 8 zone LED keypad. After disabling zone 5 zone number 17 is indicated on keypad as number 5. Bosch Sicherheitssysteme GmbH Installation Guide 2014.4 | 01 | F.01U.267.112...
8 zones and cannot display other zones, but can report zone events. For IUI- AMAX3LED16 keypad, each area can display up to 16 zones and cannot display other zones, but can report zone events. Keypad IUI -AMAX4-TEXT can display up to 64 zones. 2014.4 | 01 | F.01U.267.112 Installation Guide Bosch Sicherheitssysteme GmbH...
When the command [2] [1] is used for fault inquiry, the keypad can be programmed to sound prompt tone to indicate new system fault. The system is defaulted to enable. In case of a new fault, all keypads will sound a short beep once a minute. Bosch Sicherheitssysteme GmbH Installation Guide 2014.4 | 01 | F.01U.267.112...
Page 62
Enclosure Tamper Timing The AMAX panel supports different reaction times for the onboard tamper used for panel enclosure. The reaction time is default 400 ms and can be changed to 150 ms. 2014.4 | 01 | F.01U.267.112 Installation Guide Bosch Sicherheitssysteme GmbH...
If the default pads are short-circuited for over 10 seconds after power-up, the AMAX panel will discard resetting to factory default. 7.5.2 System View Fault Analysis AMAX panel can display eight categories of 41 kinds of system failure. Bosch Sicherheitssysteme GmbH Installation Guide 2014.4 | 01 | F.01U.267.112...
Page 64
1 - 2 Panel Aux Power 1 - 2 Fault Bosch Option Bus Power Failure 1 - 2 Bosch Option Bus 1 - 2 Power Fault RF Repeater AC Power Failure 1 - 8 RF Repeater 1-8 AC Power Fault...
Page 65
1 - 8 RF Repeater Tamper External Failure 1 - 16 External Fault Zone 1-16 For more information about fault inquiry, see Trouble Fault Inquiry, page 140. FW Version AMAX keypad displays Firmware Version. Bosch Sicherheitssysteme GmbH Installation Guide 2014.4 | 01 | F.01U.267.112...
– Zone (alarm or tamper) programmed to disable zone silent alarm – System tamper / DX2010 tamper / keypad tamper – Keypad alarm (emergency alarm, fire alarm, medical aid alarm) 2014.4 | 01 | F.01U.267.112 Installation Guide Bosch Sicherheitssysteme GmbH...
Page 67
When Programming mode is entered = one pulse activation (1sec) (enabled / disable option) 8 - Internal Siren with tamper The output is triggered when internal siren with tamper. Bosch Sicherheitssysteme GmbH Installation Guide 2014.4 | 01 | F.01U.267.112...
Page 68
The output is reset when the output programmed duration is up. lf this duration is programmed as 000, the output will continue till the tamper condition is restored and tamper is reset. 2014.4 | 01 | F.01U.267.112 Installation Guide Bosch Sicherheitssysteme GmbH...
Page 69
The output is triggered when Keyfob Button 3 is pressed. 23 - RF Keyfob button 4 The output is triggered when Keyfob Button 4 is pressed. 24 - Chime Indication Bosch Sicherheitssysteme GmbH Installation Guide 2014.4 | 01 | F.01U.267.112...
Page 70
The output is triggered when Bypassed Zone. 29 - Ready to Arm The output is triggered when ready to arm. 30 – Walk Test Output Mode The output is triggered when Walk Test Output Mode. 2014.4 | 01 | F.01U.267.112 Installation Guide Bosch Sicherheitssysteme GmbH...
Page 71
RF keyfob button 4 (light) Chime indication *1 Verified alarm Unverified alarm Technical alarm Bypassed zone Ready to arm 0 = All areas 1 - 16 = Areas 1 - 16* Bosch Sicherheitssysteme GmbH Installation Guide 2014.4 | 01 | F.01U.267.112...
/ noise ratio distance. In dependency of the rating, AMAX panel provides an estimation of GOOD or RELOCATE. Clear RF devices The AMAX panel provides the option to clear all RF devices in a step. Bosch Sicherheitssysteme GmbH Installation Guide 2014.4 | 01 | F.01U.267.112...
Connect the programming key to the plug on top of the printed circuit board (PCB) of the AMAX panel. Please note that the direction of the programming key should be consistent with the direction marked on the PCB. 2014.4 | 01 | F.01U.267.112 Installation Guide Bosch Sicherheitssysteme GmbH...
Page 75
Unplug the programming key from the AMAX panel. LED / Icon LCD keypad can also be used to copy key parameters to the AMAX panel. For more information refer to Command 963 . Bosch Sicherheitssysteme GmbH Installation Guide 2014.4 | 01 | F.01U.267.112...
Select [Save and Exit] and press [#] to save system programming data, exit menu programming, and reset system. Warning! Programming parameters must be set within the range of the programming address. Otherwise, the system will turn to an indeterminate status. 2014.4 | 01 | F.01U.267.112 Installation Guide Bosch Sicherheitssysteme GmbH...
Page 77
= Call the control panel and allow the phone to ring no more than four times and then hang up. If you call again within 45 sec, the control panel answers the call on the first ring. Figure 8.1: Com+Report Bosch Sicherheitssysteme GmbH Installation Guide 2014.4 | 01 | F.01U.267.112...
0 = disabled 1 = enabled INT SIREN INDIC ON 0 = disabled 1 = enabled SIREN OFF ANY KEY 0 = disabled 1 = enabled Figure 8.6: Output setting 2014.4 | 01 | F.01U.267.112 Installation Guide Bosch Sicherheitssysteme GmbH...
Page 83
MANUAL and AUTO. MANUAL Type 9-digit value for RFID. Press # to confirm. AUTO Press Keyfob button and wait until KEYFOB ID is displayed by the system. Press # to confirm. Bosch Sicherheitssysteme GmbH Installation Guide 2014.4 | 01 | F.01U.267.112...
Entering [9] [5] [9] + [#] means not to save the programming data. For LED / Icon LCD keypad, the programming data is displayed by the keypad indicator. See Programming Data Indicators. Programming Data Indicators Data Zone Indicators Value Mains 2014.4 | 01 | F.01U.267.112 Installation Guide Bosch Sicherheitssysteme GmbH...
“installer code” is the same as currently programmed in the AMAX panel. The value is 1234, when firmware of the AMAX panel was upgraded or the AMAX panel has factory settings. Refer to , page 87 Bosch Sicherheitssysteme GmbH Installation Guide 2014.4 | 01 | F.01U.267.112...
AMAX panel via USB cable. Plug cable into USB port of AMAX panel and connect the other side of this cable to an USB port of the PC running A-Link Plus software. 2014.4 | 01 | F.01U.267.112 Installation Guide Bosch Sicherheitssysteme GmbH...
Page 87
Configuration | en Install USB driver. The device driver is located in A-Link plus application path (example: C\ \program files (x86)\Bosch Security System\A-Link Plus\USB_DRIVER).This installation will create an additional COM device on the PC. When finished installation, identify the COM-Port associated to this device.
Run RPS on the remote PC and set relevant parameters in relevant operating interfaces. – Go to “File” and click “Communication Settings” to set parameters related to modem in the communication Settings tab page, then click “Save” 2014.4 | 01 | F.01U.267.112 Installation Guide Bosch Sicherheitssysteme GmbH...
Page 89
“Customer Information” tab page. The “Customer Number” must be entered. Enter the telephone number connected to the AMAX panel in “AMAX Panel Telephone Number”. The AMAX panel telephone number does not need to be set for manual connection. Bosch Sicherheitssysteme GmbH Installation Guide 2014.4 | 01 | F.01U.267.112...
Page 90
Or manual dialing connection: Select “Modem Connect” in the “Link” tab page and click “Wait for Incoming Call”, then initiate callback call from the AMAX panel with keypad: Enter SUBSCRIBER NUMBER, press [5] [7], and then [#]. 2014.4 | 01 | F.01U.267.112 Installation Guide Bosch Sicherheitssysteme GmbH...
(addresses 0162 - 0179), i.e., enter IP address, port number of RPS, and DHCP update time on the AMAX panel. Run RPS on the remote PC and set relevant parameters in relevant operating interfaces. Bosch Sicherheitssysteme GmbH Installation Guide 2014.4 | 01 | F.01U.267.112...
Page 92
The prompt information will recommend the SUBSCRIBER NUMBER, the AMAX panel received the last time IP address and port number.. Under DHCP environment, it is not necessary to set “AMAX Panel IP Address” and “AMAX Panel Port Number”. 2014.4 | 01 | F.01U.267.112 Installation Guide Bosch Sicherheitssysteme GmbH...
Page 93
Or manual IP connection: Select “Network Connection” and click “Wait for Incoming Call” in the “Link” tab page. Then initiate IP connection from the AMAX panel with keypad: Enter SUBSCRIBER NUMBER, press [5] [7], and then [#]. Bosch Sicherheitssysteme GmbH Installation Guide 2014.4 | 01 | F.01U.267.112...
Page 94
AMAX panel parameters, remote arming/disarming, viewing log, and so on. After IP successfully connected, RPS will disconnect it with the AMAX panel after 5 minutes of idling if you select “Auto disconnect when idle connection exceeds 5 minutes” option. 2014.4 | 01 | F.01U.267.112 Installation Guide Bosch Sicherheitssysteme GmbH...
Network polling time for receiver (001 - 999 minutes ) 0087 - 089 Telephone number / IP address and port for receiver 4 0090 - 0106 Subscriber ID number (0 – 9, B – F) 0107 - 0112 000000 Bosch Sicherheitssysteme GmbH Installation Guide 2014.4 | 01 | F.01U.267.112...
Page 99
This function is only accessible in address programming Onboard Tamper Reaction Time Address 0185 Address Default 0 = 400 ms, 1 = 150 ms 0185 1=Incert – This function is only accessible in address programming Bosch Sicherheitssysteme GmbH Installation Guide 2014.4 | 01 | F.01U.267.112...
Address 0210 - 0361 Zone function # 00 Address Default Zone type 0210 - 0211 Force arm / zone bypass 0212 VDS-A EN=0/2 Silent alarm / chime mode 0213 VDS-A EN=0/2 Bosch Sicherheitssysteme GmbH Installation Guide 2014.4 | 01 | F.01U.267.112...
Page 102
0242 VDS-A EN=0/2 Silent alarm / chime mode 0243 VDS-A EN=0/2 Zone pulse count 0244 VDS-A EN=0 Zone lockout 0245 Zone tamper (DEOL) 0246 Zone status report 0247 VDS-A EN=1/5/6/7 2014.4 | 01 | F.01U.267.112 Installation Guide Bosch Sicherheitssysteme GmbH...
Page 103
0276 Zone status report 0277 VDS-A EN=1/5/6/7 Unverified alarm report / cross zone 0278 VDS-A EN=0 Domestic number 0279 Zone function # 07 Address Default Zone type 0280 - 0281 Bosch Sicherheitssysteme GmbH Installation Guide 2014.4 | 01 | F.01U.267.112...
Page 104
Zone type 0310 - 0311 Force arm / zone bypass 0312 VDS-A EN=0/2 Silent alarm / chime mode 0313 VDS-A EN=0/2 Zone pulse count 0314 VDS-A EN=0 Zone lockout 0315 2014.4 | 01 | F.01U.267.112 Installation Guide Bosch Sicherheitssysteme GmbH...
Page 105
Zone pulse count 0344 VDS-A EN=0 Zone lockout 0345 Zone tamper (DEOL) 0346 Zone status report 0347 VDS-A EN=1/5/6/7 Unverified alarm report / cross zone 0348 VDS-A EN=0 Domestic number 0349 Bosch Sicherheitssysteme GmbH Installation Guide 2014.4 | 01 | F.01U.267.112...
Page 106
For the range of each zone function option, see zone function options below. Zone Function Options Zone function option Description Zone type Zone not used Instant Interior instant Delay Interior delay Follower Interior follower 24-hour Key-switch toggle Key switch on / off 2014.4 | 01 | F.01U.267.112 Installation Guide Bosch Sicherheitssysteme GmbH...
Page 107
1 time alarm lockout 3 times alarm lockout 6 times alarm lockout Alarm duration Zone Tamper (DEOL) Disabled Enabled Zone Status Report No report required Receiver 1 Receiver 2 Receiver 3 Receiver 4 Bosch Sicherheitssysteme GmbH Installation Guide 2014.4 | 01 | F.01U.267.112...
Page 109
* AMAX 4000 supports up to 64 zones, 16 keypads, and 16 areas AMAX 3000 supports up to 32 zones, 8 keypads, and 8 areas AMAX 2100 supports up to 8 zones, 4 keypads, and 2 areas *** AMAX 3000 / 4000 Bosch Sicherheitssysteme GmbH Installation Guide 2014.4 | 01 | F.01U.267.112...
VDS-A EN=0 Output time 0539 - 0541 VDS-A EN=180 * AMAX 4000 Notice! When the zone activating alarm is programmed as a silent alarm, keypad and audible alarm have no output. 2014.4 | 01 | F.01U.267.112 Installation Guide Bosch Sicherheitssysteme GmbH...
Page 123
/ disarming, bypass, and alarm reset operations can be performed on the master keypad. Operations can be performed in the area only if the master keypad is switched to the corresponding area. Bosch Sicherheitssysteme GmbH Installation Guide 2014.4 | 01 | F.01U.267.112...
Page 134
å æ ç è é ê ë ì í î ï ð ñ ò ó ô ô ö ÷ ø ù ú û ü ý þ ÿ Table 9.5: Characters 2014.4 | 01 | F.01U.267.112 Installation Guide Bosch Sicherheitssysteme GmbH...
Page 137
Zone name may have up to 18 characters. Each character of the zone name uses 2 addresses. Example: A = 4 1, A = Address 3736 = 4, Address 3737 = 1 Bosch Sicherheitssysteme GmbH Installation Guide 2014.4 | 01 | F.01U.267.112...
The tamper switch is not circuit jumper connected – Connect modules for – External module should programming such as be used for DX2010, DX3010, B426, programming, but it not or ITS-DX4020-G actually connected 2014.4 | 01 | F.01U.267.112 Installation Guide Bosch Sicherheitssysteme GmbH...
Page 139
0144 to a number from 1 address 0144 is set to 0) to 15 – There are multiple areas – The telephone arming is in the system available when the system has area 1 only Bosch Sicherheitssysteme GmbH Installation Guide 2014.4 | 01 | F.01U.267.112...
When the fault is reset, send the restored report to the configured destinations. The FAULT indicator is turned off, when there is no other system fault. – Output Expansion Module Failure Condition: No communication with DX3010 if DX3010 is programmed. Restore: 2014.4 | 01 | F.01U.267.112 Installation Guide Bosch Sicherheitssysteme GmbH...
Page 141
The printer and DX4010 are normal and fault is reset. Supervise: Report the printer error to configured destination when the fault is detected. Slow flash FAULT indicator (refer to Keypad Indicators the detailed description). Bosch Sicherheitssysteme GmbH Installation Guide 2014.4 | 01 | F.01U.267.112...
Page 142
Supervise: Report the wireless zone missing fault to configured destination when the fault is detected. Slow flash FAULT indicator (refer to Keypad Indicators for the detailed description). 2014.4 | 01 | F.01U.267.112 Installation Guide Bosch Sicherheitssysteme GmbH...
Page 143
Slow flash FAULT indicator (refer to Keypad Indicators for the detailed description). When the fault is reset, the FAULT indicator is turned off when there is no other system fault. Configuration Conflict Keyfobs Condition: Any one keyfob configuration is error. Restore: Bosch Sicherheitssysteme GmbH Installation Guide 2014.4 | 01 | F.01U.267.112...
Page 144
Monitor the voltage by MPU. Report the AUX power fault to the configured destination programmed on address 124. Slow flash FAULT indicator (refer to Keypad Indicators for the detailed description). 2014.4 | 01 | F.01U.267.112 Installation Guide Bosch Sicherheitssysteme GmbH...
Page 145
Voltage is raised to 12V and fault is reset. Supervise: Monitor the voltage by MPU. Report the Bosch Option Bus Power Supply fault to the configured destination programmed on address 124. Slow flash FAULT indicator (refer to Keypad Indicators for the detailed description).
Page 146
The FAULT indicator is turned off when there is no other system fault. 5- System Failure – Date and Time not set Condition: Date and time is not set after the system is powered on. Restore: 2014.4 | 01 | F.01U.267.112 Installation Guide Bosch Sicherheitssysteme GmbH...
Page 147
When the Tamper Condition is reset, send the restored report to the configured destinations. The FAULT indicator is turned off when there is no other system fault. Zone Expansion Module Tamper Zone expansion module 1 to 6 tamper Bosch Sicherheitssysteme GmbH Installation Guide 2014.4 | 01 | F.01U.267.112...
Page 148
Report the keypad lock out to configured destination on address 124 when the keypad lock out is detected. Slow flash FAULT indicator (refer the detailed description in chapter keypad indicators). 2014.4 | 01 | F.01U.267.112 Installation Guide Bosch Sicherheitssysteme GmbH...
Page 149
When the fault is reset, send the restored report to the configured destinations. The FAULT indicator is turned off when there is no other system fault. External Fault Zone The zone indicator 8 lights to indicate external fault conditions. Bosch Sicherheitssysteme GmbH Installation Guide 2014.4 | 01 | F.01U.267.112...
Power ON AMAX panel. Observe LED of upgrade key flickers during upgrade is sent to AMAX panel. This takes about one minute. When upgrade is terminated, LED blinks slowly. Remove upgrade key 2014.4 | 01 | F.01U.267.112 Installation Guide Bosch Sicherheitssysteme GmbH...
Events: 256 history events, stamped with time, and date 256EN history events, stamped with time, and date 256 dialer history events, stamped with time, and date Pin Code 1000000 variations: Bosch Sicherheitssysteme GmbH Installation Guide 2014.4 | 01 | F.01U.267.112...
Page 152
1000mA (recharge Batt 80% in 24h) = 400mA Aux 1 / 2 (+12V/ – Nominal Output Voltage under AC line input: 13,8 VDC +3% / -5% GND) Output: – Vpp (max) 675mV 2014.4 | 01 | F.01U.267.112 Installation Guide Bosch Sicherheitssysteme GmbH...
Page 153
10.8VDC - 13.8VDC range: Current standby 31mA Consumption: max 100mA Ingress protection IP 30 rating: Security level: IK 06 Certification: Europe EN 50130-4 (6/2011) EN 55022 (5/2008) EN 60950-1:2006 + A11:2009 Bosch Sicherheitssysteme GmbH Installation Guide 2014.4 | 01 | F.01U.267.112...
Page 154
EN type: EN = B, IK = 06, IP = 30 Certification: Europe EN 50130-4 (6/2011) EN 55022 (5/2008) EN 60950-1:2006 + A11:2009 EN 50131-3 grade 2 Environmental Class 2 2014.4 | 01 | F.01U.267.112 Installation Guide Bosch Sicherheitssysteme GmbH...
Page 155
AMAX panel 4000 / AMAX panel 4000 Technical Data | en France AFNOR NF a2P 1223400001A0 Environmental Class 1 Germany Home Bosch Sicherheitssysteme GmbH Installation Guide 2014.4 | 01 | F.01U.267.112...