Cisco IX5000 and IX5200 Installation Guide
Cisco TelePresence IX5000 and IX5200

Installation Guide

Revised: April 16, 2015
Page 1
© 2015 Cisco Systems, Inc. All rights reserved.

Advertisement

Table of Contents
loading

Summary of Contents for Cisco TelePresence IX5000

  • Page 1: Installation Guide

    Cisco IX5000 and IX5200 Installation Guide Cisco TelePresence IX5000 and IX5200 Installation Guide Revised: April 16, 2015 Page 1 © 2015 Cisco Systems, Inc. All rights reserved.
  • Page 2: Installation Sequence

    Cisco IX5000 and IX5200 Installation Guide Installation Sequence Page 2 © 2015 Cisco Systems, Inc. All rights reserved.
  • Page 3 Cisco IX5000 and IX5200 Installation Guide Finding Immersive Room Recommendations For the latest room size, power, HVAC, lighting, and acoustic recommendations for your immersive TelePresence room, refer to the “Cisco TelePresence IX5000 and IX5200 Room Recommendations” document at http://www.cisco.com/c/en/us/td/docs/telepresence/ix5000/recommendations/ix5000_room_requirements.html. Installation Quick Reference Move material and unpack (2 people required) 2.
  • Page 4 19mm 12-point ratcheting box end wrench • Spirit level or digital Level • Laser level with tripod • White gloves (included with accessory kit) • Metric tape measure • Box cutter Page 4 © 2015 Cisco Systems, Inc. All rights reserved.
  • Page 5 Follow the instructions in the manual when installing these parts. • In this manual, Left or Right always means “left or right as viewed from the front of the system”. Page 5 © 2015 Cisco Systems, Inc. All rights reserved.
  • Page 6: Installing The Lower And Upper Display Frames

    (800-40934-xx, 800-40948-xx, 800-40941-xx) • Metric tape measure • 2x Tie bars 700-43084-xx • Spirit level • 56x black M8 X 16mm screws 69-2792-xx • Laser level • 1x compliance label 47-27415-xx Page 6 © 2015 Cisco Systems, Inc. All rights reserved.
  • Page 7 40928-xx right) upside-down on the floor, and check that there is 2 inches (51mm) from the bottom of the frame to the bottom of the feet. If adjustment is required, loosen the 19mm lock nut. 2” (51 mm) Leveling 19mm lock nut foot Page 7 © 2015 Cisco Systems, Inc. All rights reserved.
  • Page 8 800-40920-xx. Align the pins on the side of 800-40920-xx with the hole and slot on the side of 800-40923-xx. Install and tighten 6x black M8 X 16mm screws 69-2792-xx using a #3 Phillips driver. 800-40920-xx 800-40923-xx Diamond shows center of system 6x 69-2792-xx Page 8 © 2015 Cisco Systems, Inc. All rights reserved.
  • Page 9 40928-xx with the hole and slot on the side of 800-40920-xx. Install 6x black M8 X 16mm screws 69- 2792-xx and tighten using a #3 Phillips driver. 800-40928-xx 800-40920-xx 6x 69-2792-xx Page 9 © 2015 Cisco Systems, Inc. All rights reserved.
  • Page 10 Measure two positions (left side and right side of the center frame) to ensure that the frame is parallel to the rear wall. Rear Wall Minimum 6” (150 mm) Page 10 © 2015 Cisco Systems, Inc. All rights reserved.
  • Page 11 13mm hex profile above each foot. Diamond-shaped leveling mark Foot A Foot C Foot B Foot C Foot B Foot A 19mm Lock nut 13mm hex profile Page 11 © 2015 Cisco Systems, Inc. All rights reserved.
  • Page 12 Adjust the system for plumb (side-to-side) adjustment by raising or lowering the two outer feet marked “A” by the same amount while checking plumb with a level. Foot A Foot A Page 12 © 2015 Cisco Systems, Inc. All rights reserved.
  • Page 13 (a slot on the left side of the upper frame, a hole on the right). Install 8x black M8 X 16mm screws 69-2792-xx and tighten with a #3 Phillips driver. 800-40948-xx Slot 8x 69-2792-xx Page 13 © 2015 Cisco Systems, Inc. All rights reserved.
  • Page 14 Assemble the upper left frame 800-40934-xx to the display structure. Align the slots and pins in the vertical beams, then place the upper frame on the lower frame and align the pin and slot in the horizontal beams. 800-40934-xx Slot 800-40923-xx Page 14 © 2015 Cisco Systems, Inc. All rights reserved.
  • Page 15 Install 8x black M8 X 16mm screws 69-2792-xx in the vertical columns and tighten using a #3 Phillips driver. Install and tighten these screws before installing the screws on the horizontal beam. 800-40934-xx 8x 69-2792-xx Page 15 © 2015 Cisco Systems, Inc. All rights reserved.
  • Page 16 Installing the Lower and Upper Display Frames Install 6x black M8 X 16mm screws 69-2792-xx in the horizontal beam and tighten using a #3 Phillips driver. 800-40934-xx 6x 69-2792-xx 800-40923-xx Page 16 © 2015 Cisco Systems, Inc. All rights reserved.
  • Page 17 Install the upper right frame 800-40941-xx to the display structure following the same procedure as the upper left frame using 14x black M8 X 16mm 69-2792-xx screws. Install and tighten the side screws first. 8x 69-2792-xx 800-40941-xx 6x 69-2792-xx 800-40928-xx Page 17 © 2015 Cisco Systems, Inc. All rights reserved.
  • Page 18 Loosen the lock nut using a 13mm or adjustable wrench before adjusting the height of the leveler. Do not re-tighten the lock nut. 2 3/8” (60 mm) Page 18 © 2015 Cisco Systems, Inc. All rights reserved.
  • Page 19 Installing the Lower and Upper Display Frames Assemble 2x tie bars 700-43084-xx to the rear left and right sides of the frames using 8x black M8 X 16mm screws 69-2792-xx. 2x 700-43084-xx 8x 69-2792-xx Page 19 © 2015 Cisco Systems, Inc. All rights reserved.
  • Page 20 (backwards). After you install the displays, the structure will lean slightly forward and bring it back to level. Make sure that distance from wall is even Laser level is aligned with the left point of the diamond Foot B Foot C Foot A Page 20 © 2015 Cisco Systems, Inc. All rights reserved.
  • Page 21 Attach the compliance label 47-27415-xx to the pillar on the left side of the lower left display frame. Use the four locating marks on the frame to find the correct placement. 1x 47-27415-xx Page 21 © 2015 Cisco Systems, Inc. All rights reserved.
  • Page 22: Installing The Cable Runner

    • 2x Cable runner bridges 700-43302-xx • 4x Black M4 X 12mm long screws with external lock washer 48-2426-xx • 1x Cable runner plate 700-44717-xx • 4x M6x10mm screws 69-2803-xx Page 22 © 2015 Cisco Systems, Inc. All rights reserved.
  • Page 23 4x black M4x12mm screws 48-2426-xx using a #2 Phillips screwdriver. Install the cable runner plate 700-44717-xx to the cable runner 700-42946-xx with 4x M6x10mm screws 69-2803-xx. 700-43302-xx 4x 48-2426-xx 700-42946-xx 4x 69-2803-xx 700-44717-xx Page 23 © 2015 Cisco Systems, Inc. All rights reserved.
  • Page 24 (not on the ribs). Lower the brackets Loosen 3x screws on each side Slide the cable runner into position Page 24 © 2015 Cisco Systems, Inc. All rights reserved.
  • Page 25 Installing the Cable Runner Attach the 4x captive fasteners (2x fasteners per bracket) on the cable runner to the display frames. Re-tighten the 6x M8 screws on both brackets with the hex driver. Page 25 © 2015 Cisco Systems, Inc. All rights reserved.
  • Page 26: Installing The Pillars, Crossbars, And Rear Kick Plate/Toe Cap

    • 1x Cardboard spacer no part number, attached to the cable runner base Rear toe caps: • 3x Center, left, and right toe caps (center 700-43094-xx, left 700-43095-xx, right 700-43093-xx) • 10x M4 nut with lock washer 69-2793-xx Page 26 © 2015 Cisco Systems, Inc. All rights reserved.
  • Page 27 Attach the pillars to the frame with 32x M4 X 12mm screws 69-2797-xx (4x for each pillar) using a #2 Phillips screwdriver. 4x 69-2797-xx 700-43514-xx 700-43516-xx 700-43516-xx 700-43514-xx 2x 700-43514-xx 700-43515-xx 700-43515-xx Page 27 © 2015 Cisco Systems, Inc. All rights reserved.
  • Page 28 Place the horizontal crossbars (700-43519-xx left, 700-43517-xx center, 700-43518-xx right) on the pillars and fasten with 14x black M4 X 12mm screws 69-2797-xx using a #2 screwdriver. 14x 69-2797-xx 700-43518-xx 700-43519-xx 700-43517-xx Page 28 © 2015 Cisco Systems, Inc. All rights reserved.
  • Page 29 Attach the lower rear kick plate 700-43100-xx to the endpoint structure. Align the threaded studs to the slots in the display stand, then loosely install (but do not fully tighten) using 2x M4 nuts 69-2793-xx. 700-43100-xx 2x 69-2793-xx Page 29 © 2015 Cisco Systems, Inc. All rights reserved.
  • Page 30 2x M4 nuts you attached in Step 3. Save the spacer. You will use it when you install the front kick plates. Minimum 1” Minimum 1” (26 mm) (26 mm) Cardboard spacer 2x 69-2793-xx (viewed from opposite side) Page 30 © 2015 Cisco Systems, Inc. All rights reserved.
  • Page 31 Install the rear center toe cap 700-43094-xx to the kick plate by placing the threaded studs into the holes in the display stand and installing and tightening the 4x M4 nuts 69-2793-xx. 700-43094-xx Stud Hole 4x 69-2793-xx Page 31 © 2015 Cisco Systems, Inc. All rights reserved.
  • Page 32 Place the studs (one for each kick plate) into the slot in the frame. Stud 700-43101-xx 700-43099-xx Slot Notch Page 32 © 2015 Cisco Systems, Inc. All rights reserved.
  • Page 33 Using a level, level the rear side kick plates with the rear center kick plate. Attach the x2 M4 nuts with lock washer 69-2793-xx to the stud for each plate and tighten with the 7mm hex driver. Level here 2x 69-2793-xx Page 33 © 2015 Cisco Systems, Inc. All rights reserved.
  • Page 34 700-43095-xx into the holes in frame. Attach the x3 M4 nuts with lock washer 69-2793-xx to the stud and tighten with the 7mm hex driver. Repeat for the right toe cap. 700-43093-xx 700-43095-xx Hole Stud 6x 69-2793-xx Page 34 © 2015 Cisco Systems, Inc. All rights reserved.
  • Page 35 69-100186-xx (part of kit 69-100184-xx and included with the switch brackets) • 4x black M4x12 mm screw with external tooth lock washer 69-100185-xx (part of kit 69-100184-xx and included with the switch brackets) Page 35 © 2015 Cisco Systems, Inc. All rights reserved.
  • Page 36 Assemble the brackets (700-43404-xx left, 700-44771-xx right) to the sides of the encoder/decoder codec 800-39337-xx using 8x black M4x12mm screws 69-2797-xx. Tighten with a #2 Phillips driver. 700-43404-xx 800-39337-xx 700-44771-xx 4x 69-2797-xx 4x 69-2797-xx Page 36 © 2015 Cisco Systems, Inc. All rights reserved.
  • Page 37 Install 6x black M8x16mm screws 69-2792-xx and tighten with a #3 Phillips driver. Slot Hook 800-39337-xx 6x 69-2792-xx Page 37 © 2015 Cisco Systems, Inc. All rights reserved.
  • Page 38 Assemble the brackets (700-43404-xx left, 700-43573-xx right) to the sides of the Host CPU codec 800-41502-xx using 8x black M4x12mm screws 69-2797-xx. Tighten with a #2 Phillips driver. 700-43573-xx 700-43404-xx 800-41502-xx 4x 69-2797-xx 4x 69-2797-xx Page 38 © 2015 Cisco Systems, Inc. All rights reserved.
  • Page 39 / sliding into place. Engage the hook on the left side bracket with the slot in the frame. Install using 6x black M8x16mm screws 69-2792-xx and tighten with a #3 Phillips driver. 800-41502-xx Slot Hook 6x 69-2792-xx Page 39 © 2015 Cisco Systems, Inc. All rights reserved.
  • Page 40 69-100184-xx (included with the switch brackets). Engage the tabs on the brackets with the slots in the switches. Tighten the screws with a #2 Phillips driver. 4x 69-100184-xx 700-43091-xx Slot 2x WS-C2960C-12PC-L 700-43090-xx Page 40 © 2015 Cisco Systems, Inc. All rights reserved.
  • Page 41 Optional: Installing the LAN switches: Install the switches and brackets by engaging the two bottom hooks in the slots in the frames. Install 4x black M4 X 12mm screws 69-2797-xx and tighten with a #2 Phillips driver. Hook Slot 4x 69-2797-xx Page 41 © 2015 Cisco Systems, Inc. All rights reserved.
  • Page 42: Installing The Subwoofer And Speakers

    • 2x silver M4 washer 69-2796-xx • 2x M4 nut with lock washer 69-2793-xx Speakers: • 6x Speakers 74-12204-xx • 2x Speaker Mounting Block 700-47073-xx • 48x Black M3 Shoulder Screw 69-2791-xx Page 42 © 2015 Cisco Systems, Inc. All rights reserved.
  • Page 43 341-0414-xx into the channel on the back of the bracket and plug the power supply into the bottom of the amp. 800-42333-xx 2x 69-2793-xx 341-0414-xx Cord from power supply plugs into amp Page 43 © 2015 Cisco Systems, Inc. All rights reserved.
  • Page 44 Install the 2x silver M4 washers 69-2796-xx to the 2x M4x12mm screws 69-2797-xx and tighten with a #2 Phillips driver. 700-43076-xx 2x 69-2796-xx 2x 69-2797-xx 74-12848-xx - back side Page 44 © 2015 Cisco Systems, Inc. All rights reserved.
  • Page 45 Rotate the woofer backward, install 2x M4x12mm screws 69-2797-xx, and tighten with a #2 Phillips driver. 2x 69-2797-xx Rubber feet Page 45 © 2015 Cisco Systems, Inc. All rights reserved.
  • Page 46 4x Black M3 Shoulder Screws 69-2791-xx (2x per pillar). NOTE: only the two center vertical pillars use this block. Note the speaker icon, which points toward the speakers after they are installed. 2x 700-47073-xx Note speaker icon - points toward Center pillars speaker 4x 69-2791-xx Page 46 © 2015 Cisco Systems, Inc. All rights reserved.
  • Page 47 Installing the Subwoofer and Speakers Mount the speaker 74-12204-xx to the rubber block and attach it using 4x Black M3 shoulder screws 69-2791-xx per speaker. Do not use a power driver for these screws, as this might cause damage to the thread inserts. 74-12204-xx 4x 69-2791-xx Page 47 © 2015 Cisco Systems, Inc. All rights reserved.
  • Page 48 Installing the Subwoofer and Speakers Install the four remaning speakers using 4x Black M3 Shoulder Screw 69-2791-xx per speaker. Do not use a power driver when installing the screws to avoid damage to the thread inserts. 4x 74-12204-xx Page 48 © 2015 Cisco Systems, Inc. All rights reserved.
  • Page 49: Starting Installation And Cabling Of The Front Row Table

    2x #10-32 screws 69-100184-xx 2x Jumper Cable, 2 meter, 37-0994-xx no reference designator - extra jumper cables for middle legs 1x Microphone Connector (MC) 800-40951-xx Velcro cables 52-0449-xx as needed Page 49 © 2015 Cisco Systems, Inc. All rights reserved.
  • Page 50 Incorrect - Long slot on plate matches with slot Correct - Cloverleaf pattern on table leg. Remove the three screws, flip plate on plate matches with slot 180 degrees, and reattach on table leg 800-41001-xx and 800-44195-xx Page 50 © 2015 Cisco Systems, Inc. All rights reserved.
  • Page 51 800-41002-xx) upside down. Adjust the levelers until there is 1 inch (25mm) between the bottom edge of the leg and the base of the foot. 25mm (1”) 4x first row table legs (1x 800-41001-xx , 1x 800-44195-xx & 2x 800-41002-xx) Page 51 © 2015 Cisco Systems, Inc. All rights reserved.
  • Page 52 Align the pins on the front row cable management assembly 800-40845-xx with hole and slot on the inner table legs (800-44195-xx left, 800-41001-xx right). then connect the legs to the assembly using 6x M8x16mm screws 69-2792-xx (3 per leg). 800-40845-xx 800-44195-xx 6x 69-2792-xx 800-41001-xx Page 52 © 2015 Cisco Systems, Inc. All rights reserved.
  • Page 53 Loosely attach the Cable Runner Bracket to the Front Row assembly by by sliding the slots in the Cable Runner Bracket onto the two M6 studs located on the Front Row Cable Management assembly. Attach 2x M6 nuts 69-2800-xx to the studs finger-tight. 2x 69-2800-xx Page 53 © 2015 Cisco Systems, Inc. All rights reserved.
  • Page 54 Connect the left table leg 800-41002-xx using the same procedure, using the 700-44719-xx left connector and 4x M8x16mm screws 69-2792-xx. 700-44718-xx 700-44719-xx 800-41002-xx 800-41002-xx 4x 69-2792-xx 4x 69-2792-xx Right side Left side Page 54 © 2015 Cisco Systems, Inc. All rights reserved.
  • Page 55 Check table height by aligning these notches on the table legs (inside or outside) with the diamonds on the endpoint structure Diamond in center of table assembly aligns with diamond on center of endpoint structure Page 55 © 2015 Cisco Systems, Inc. All rights reserved.
  • Page 56 700-46218-xx far left) into the table legs. Use 8x M6x10mm 69-2803-xx screws to attach these to the table leg brackets (2 screws per bracket). 700-44754-xx 700-44755-xx 700-46219-xx 700-46218-xx 700-46219-xx 8x 69-2803-xx 700-44755-xx Page 56 © 2015 Cisco Systems, Inc. All rights reserved.
  • Page 57 04-40 nuts 49-0326-xx. Tip: Hold the cover flat and install the nuts from below using a nut driver to facilitate installation. 2x Inside legs 2x outside legs 700-45421-xx 700-47772-xx 2x Power/Ethernet 700-47772-xx 1x Power/Ethernet Modules 8x #4-40 nuts 8x #4-40 nuts Modules Page 57 © 2015 Cisco Systems, Inc. All rights reserved.
  • Page 58 Insert the modules with two outlets into the 2x inside table legs and insert the modules with one outlet and one blanking plate into the 2x outside table legs. Assembled power/Ethernet connectivity modules Page 58 © 2015 Cisco Systems, Inc. All rights reserved.
  • Page 59 Outside table legs - insert extra jumper cable and route clear from yellow dotted area as shown. Inside behind power connector - note jumper connections legs do NOT get an extra jumper cable. Page 59 © 2015 Cisco Systems, Inc. All rights reserved.
  • Page 60 Connector, with the single connector facing to the right, and the six connectors facing to the left. WS-C2960C- 8PC-L 2x 700-44758- xx & 2x 69-100184- 2x 69-2800-xx 800-40951-xx - note six 2x 69-2800-xx connectors on right and one connector on left Page 60 © 2015 Cisco Systems, Inc. All rights reserved.
  • Page 61 All cables routing down to the cable runner must come from the sides - routing from the top could interfere with the installation of the cable runner cap Page 61 © 2015 Cisco Systems, Inc. All rights reserved.
  • Page 62 Legend: • Green - Microphone Connec- tor/mic bars • Red - power cables • Blue - Ethernet cables • Orange - presentation cables Inside leg power/Ethernet cables Page 62 © 2015 Cisco Systems, Inc. All rights reserved.
  • Page 63 Starting Installation and Cabling of the Front Row Table Level the system, and measure the distance between the outside table legs and the edges of the display stands in the endpoint structure. 1111 mm 1111 mm Page 63 © 2015 Cisco Systems, Inc. All rights reserved.
  • Page 64: Cable Routing And Cable Diagrams

    • 3x Light bar cables, 37-100748-xx, L1, L2, L3 • 3x RCA Y cable for speaker 37-1557-xx L4, L4 R&L, L5, L5 R&L, L6, L6 R&L • 1x DisplayPort-to-DisplayPort cable, 2 meter, 37-1547-xx Page 64 © 2015 Cisco Systems, Inc. All rights reserved.
  • Page 65 • Lay the camera cable directly in the center of the endpoint structure between the speakers. Tip: If you need more Velcro straps, cut them crosswise to make double the amount of straps. Page 65 © 2015 Cisco Systems, Inc. All rights reserved.
  • Page 66 Installing Endpoint Structure Cables Left PDU and Woofer Speaker Page 66 © 2015 Cisco Systems, Inc. All rights reserved.
  • Page 67 Installing Endpoint Structure Cables Codec cabling (note iPass cable between Encoder/Decoder and Host CPU codecs). Use Velcro cables as required. Page 67 © 2015 Cisco Systems, Inc. All rights reserved.
  • Page 68 Installing Endpoint Structure Cables Codec and cable runner Power cable in the left-side channel, Ethernet cables in the right-side channel, Presentation cables in the center channel Page 68 © 2015 Cisco Systems, Inc. All rights reserved.
  • Page 69 Installing Endpoint Structure Cables Codec and cable runner Page 69 © 2015 Cisco Systems, Inc. All rights reserved.
  • Page 70 Installing Endpoint Structure Cables Optional 42-inch display (use this as a guideline only - the cable runner cover will not be installed at this time) Page 70 © 2015 Cisco Systems, Inc. All rights reserved.
  • Page 71 Installing Endpoint Structure Cables Page 71 © 2015 Cisco Systems, Inc. All rights reserved.
  • Page 72 Installing Endpoint Structure Cables Page 72 © 2015 Cisco Systems, Inc. All rights reserved.
  • Page 73 6x M4 X 6mm screws, black, 69-2625-xx Display cabling kit, 69-2678-xx includes the following cables: • 3x power cord, 3 meter, 37-0833-xx • 3x HDMI-to-DVI-D patch cord, 3 meter, 37-1387-xx Page 73 © 2015 Cisco Systems, Inc. All rights reserved.
  • Page 74 69-2625-xx screw with a #2 Phillips screwdriver. Repeat for all three displays. 700-46233-xx Install on this standoff (2nd from end) 1x 69-2625-xx 700-46232-xx 1x 69-2625-xx Page 74 © 2015 Cisco Systems, Inc. All rights reserved.
  • Page 75 NOTE: For this book, left and right are as viewed from the FRONT of the system, therefore left and right are reversed. 5x bracket screws Left display Right display Page 75 © 2015 Cisco Systems, Inc. All rights reserved.
  • Page 76 MAKE SURE THAT THERE IS is 1 1/8 inch (29mm) distance between the spool and the rear of the display or you cannot install the display. 69-2625-xx 1 1/8” (29 mm) Page 76 © 2015 Cisco Systems, Inc. All rights reserved.
  • Page 77 Make sure that there is 1 1/8 inch (29mm) distance between the spool and the rear of the display for correct installation of the display. 69-2625-xx 1 1/8” (29 mm) Page 77 © 2015 Cisco Systems, Inc. All rights reserved.
  • Page 78 Temporarily hang the right display onto the frame rail of the structure using the top hooks. Connect the power, DVI, and fan cables. TURN THE DISPLAY POWER SWITCH TO THE ON POSITION. Frame rail Display top hooks 74-12597-xx DVI connector Fan connector Power switch AC connector Page 78 © 2015 Cisco Systems, Inc. All rights reserved.
  • Page 79 Note that the display is not supported by the top hooks on the frame rail. CAUTION: Do not pinch your hand between the display and the support bracket. Slot Spool Leveling bracket Leveler Display View from back Support bracket Page 79 © 2015 Cisco Systems, Inc. All rights reserved.
  • Page 80 Temporarily hang the center display using the top hooks and frame rail and rotate the frame out to connect the power, DVI, and fan cables. TURN THE SWITCH FOR THE DISPLAY TO THE ON POSITION. 74-12597-xx Cable access from this side Page 80 © 2015 Cisco Systems, Inc. All rights reserved.
  • Page 81 Installing and Cabling the Displays Move the center display into the display frame. CAUTION: Do not pinch your hand between the display and the support brackets. Display Support bracket Page 81 © 2015 Cisco Systems, Inc. All rights reserved.
  • Page 82 TURN THE SWITCH FOR THE DISPLAY TO THE ON POSITION. CAUTION: Do not pinch your hand between the display and the support bracket. DVI connector Power switch & power connector Leveling Slot bracket View from back Spool Leveler Page 82 © 2015 Cisco Systems, Inc. All rights reserved.
  • Page 83 Tighten the lock nut on the levelers after you complete leveling. Leveling bracket Leveler View from back - use a 6mm T-handle hex driver from below to adjust levelers Page 83 © 2015 Cisco Systems, Inc. All rights reserved.
  • Page 84 Installing and Cabling the Displays Remove the protective film from the displays by pulling the tape off in the directions shown by the arrows. Page 84 © 2015 Cisco Systems, Inc. All rights reserved.
  • Page 85 Push the left and right displays from the sides towards the center against the extrusions to take up any gaps. Leave the fim on the front of the displays. Slot 2x 800-41842-xx Hook 800-41842-xx 2x 69-2797-xx Page 85 © 2015 Cisco Systems, Inc. All rights reserved.
  • Page 86 19mm ratcheting box wrench. 19mm Lock nut 13mm hex profile nut Page 86 © 2015 Cisco Systems, Inc. All rights reserved.
  • Page 87: Installing The Camera And Light Panels

    • 1x each left, center, and right speaker cover (700-46597-xx, 700-46596-xx, and 700-46595-xx respectively) • 1x each left and right fascia corner braces (700-46598-xx left, 700-46594-xx right) • 8x black M4x12mm screw with external lock washer 69-2797-xx Page 87 © 2015 Cisco Systems, Inc. All rights reserved.
  • Page 88 Attach the camera 74-12203-xx to the vertical structure supports of the endpoint structure. The screws are pre-attached to the camera. Attach the DisplayPort Cable to the port at the top of camera housing. 74-12203-xx Page 88 © 2015 Cisco Systems, Inc. All rights reserved.
  • Page 89 Fit light bar tabs behind the crossbar slots - DO NOT place in the crossbar slots Rest on Shelf DO NOT put stress on the cable at the light panel Page 89 © 2015 Cisco Systems, Inc. All rights reserved.
  • Page 90 4x captive Phillips screws. The cover fits under the small shelf on the pillar. Be careful to not pinch the light wire as shown in the below picture. Do not pinch cable 700-46596-xx 4x Captive Screws Page 90 © 2015 Cisco Systems, Inc. All rights reserved.
  • Page 91 (part of 74-12235-xx) and right speaker cover 700-46595-xx using the same procedure as the center speaker cover and light panel. After installation, make sure that the edges of the panels touch. 74-12275-xx 74-12274-xx 700-46595-xx 700-46597-xx Page 91 © 2015 Cisco Systems, Inc. All rights reserved.
  • Page 92 DO NOT place a screwdriver or other object into the hole to align them. Raise or lower the displays using the display levelers from the rear of the system to align the holes. Table Top A (700-42477-01) Table Top B (700-42476-01) Table Top C (700-42478-01) 6X 69-2797-xx Page 92 © 2015 Cisco Systems, Inc. All rights reserved.
  • Page 93 2x M4 screws 69- 2797-xx. Repeat for the right fascia corner brace 700-46594-xx. Hook & Tab Hook 2x 700-46594-xx 700-46598-xx (left), 700-46594-xx (right) Page 93 © 2015 Cisco Systems, Inc. All rights reserved.
  • Page 94: Installing The Front Kick Plates

    5x black M4x12mm screw 69-2797-xx NOTE: Make sure that all cabling between the endpoint structure and the front row table is complete before you install the front kick plates. 700-43096-xx 700-43097-xx 700-43098-xx Page 94 © 2015 Cisco Systems, Inc. All rights reserved.
  • Page 95 Attach, but do not tighten, 2x black M4x12mm screws 69-2797-xx into the center of the slot. Note the arrow that indicates the correct slot for the screw. Arrow indicates 700-43097-xx 2x 69-2797-xx correct slot Page 95 © 2015 Cisco Systems, Inc. All rights reserved.
  • Page 96 (either left or right). Tighten the 2x black M4x12mm screws 69-2797-xx, remove the spacer, and recheck the minimum 26mm of clearance. Cardboard spacer Minimum 26mm (1 inch) Page 96 © 2015 Cisco Systems, Inc. All rights reserved.
  • Page 97 Install and tighten 4x black M4x12mm screws 49-0420-xx (2 for each kick plate). Note the arrows on the kick plates that show the correct screw placement. 700-43098-xx 700-43096-xx 4x 49-0420-xx Arrows show correct screw placement Page 97 © 2015 Cisco Systems, Inc. All rights reserved.
  • Page 98 43098-xx to the rear kick plate. Re-adjust the rear kick plate to align the screw hole if needed. Repeat for the right side front kick plate 700-43096-xx. 69-2797-xx 700-43096-xx 69-2797-xx 700-43098-xx Page 98 © 2015 Cisco Systems, Inc. All rights reserved.
  • Page 99: Installing The Front Row Tabletops

    • 10mm open end or ratcheting wrench 42478-xx) 8x Biscuit Joiner, 700-23909-xx 4x Half Moon Bolt, M6 x 80mm, 51-6068-xx 4x Joint Plate, 700-23345-xx 48x M8 x 16mm screws, black 69-2792-xx Page 99 © 2015 Cisco Systems, Inc. All rights reserved.
  • Page 100 Lower Table Top Assembly A 700-42477-xx onto the table leg assembly. Do not secure the table to the legs at this time. Repeat this step with Table Top B 700-42476-xx. 700-42477-xx Page 100 © 2015 Cisco Systems, Inc. All rights reserved.
  • Page 101 With tabletop assembies A&B resting on the leg assembly, install x8 biscuit joiners 700-23909-xx (4x per seam) into the slots in the tabletops. Be sure that the biscuit joiners are fully seated in their slots. 4x 700-23909-xx 700-42477-xx 700-42476-xx 4x 700-23909-xx Page 101 © 2015 Cisco Systems, Inc. All rights reserved.
  • Page 102 Slide table top assemblies A&B together, then slide the table top slightly to the right or left, allowing enough room to install the tabletop hardware from underneath. Make sure that the tops stay on the table legs and do not fall. Page 102 © 2015 Cisco Systems, Inc. All rights reserved.
  • Page 103 Make sure the front and back edges are aligned before tightening, and make sure that the half-moon bolt assemblies are insterted all the way into their recesses in the table. 2x 51-6068-xx Page 103 © 2015 Cisco Systems, Inc. All rights reserved.
  • Page 104 Installing the Front Row Tabletops Install the joint plates 2x 700-23345-xx to the bottom of table top assemblies A&B (700-42477-xx & 700-42476-xx) by inserting 6x 69-2792-xx screws per joint plate. 6x 69-2792-xx 2x 700-23345-xx Page 104 © 2015 Cisco Systems, Inc. All rights reserved.
  • Page 105 Attach tabletop C 700-42478-xx to tabletops A&B, using the exact same parts, tools, and joining procedures as you used to join tabletops A&B. 12x 69-2792-xx 2x 51-6068-xx 2x 700-23345-xx Underside of table 700-42478-xx Table edge Page 105 © 2015 Cisco Systems, Inc. All rights reserved.
  • Page 106 Slide the tabletop assembly into its correct position, then secure it to the table legs using 24x M8x16mm screws (69-2792-xx), 6x screws per table leg. Start from the inside legs, then move outward. 6x 69-2792-xx (3 each side of leg) Page 106 © 2015 Cisco Systems, Inc. All rights reserved.
  • Page 107 • 2x 700-43423-xx - inside of inside legs • 1x 700-43425-xx - front (privacy) panel 3x cable mute button covers (1x right 700-44726-xx, 1x left 700-44727-xx, 1x center 700-45410-xx) 13x M4x10mm black screws 69-2821-xx Page 107 © 2015 Cisco Systems, Inc. All rights reserved.
  • Page 108 Table Top Assembly. Repeat for each Mute Button Assembly. 3x 74-12200-xx Mute button flush with table after installation 2x 48-2646 Mute button cable - route through to mic bar hole Page 108 © 2015 Cisco Systems, Inc. All rights reserved.
  • Page 109 IX5200 only: Turnaround mics (74-12552-xx) have a red label on underside - use for second row only - DO NOT USE for first row - Mute button cables (3 total) Page 109 © 2015 Cisco Systems, Inc. All rights reserved.
  • Page 110 One to two cables can be installed 1x Mic bar cap & 1x per mic bar, for one or two Touch 69-2801-xx screw 10 devices per segment. Check routing under the table Page 110 © 2015 Cisco Systems, Inc. All rights reserved.
  • Page 111 Do not use a power driver for these screws. Repeat this step for each mic bar assembly. 6x 43-2426-xx Place the cables into the tabletop openings Page 111 © 2015 Cisco Systems, Inc. All rights reserved.
  • Page 112 Completing Installation of the First Row Table Route the Mini-DisplayPort cables underneath the table towards the center of the structure. Table Top A (700-42477-01) Table Top B (700-42476-01) Table Top C (700-42478-01) Page 112 © 2015 Cisco Systems, Inc. All rights reserved.
  • Page 113 Table Top A (700-42477-01) Table Top B (700-42476-01) Table Top C (700-42478-01) Mic Bar 1 MC1 - to cable runner Mic Bar 2-5 Mic bar 6 Page 113 © 2015 Cisco Systems, Inc. All rights reserved.
  • Page 114 Completing Installation of the First Row Table Connect the Cisco TelePresence Touch 10 device(s) to the PoE switch in the first row table. Use velcro cable wraps as needed to secure cables and ensure that the cables are held inside of the structure so as they are not pinched when the cosmetic panels are installed.
  • Page 115 (700-42478-01) enough free play to insert the cable into the presentation cup, otherwise cut after installation Presentation hole in table Underside of table 4x SE2587 Page 115 © 2015 Cisco Systems, Inc. All rights reserved.
  • Page 116 4x 48-2091-xx (installed from other side) Retractor: NEVER cut this zip tie Retractor: Cut these zip ties if you did not cut them yet Example shows right table leg Page 116 © 2015 Cisco Systems, Inc. All rights reserved.
  • Page 117 8x M4x10mm black screws 69-2821-xx (4 for each side). Table Top A (700-42477-01) Table Top B (700-42476-01) Table Top C (700-42478-01) 700-44726-xx 4x 69-2821-xx 700-44727-xx Page 117 © 2015 Cisco Systems, Inc. All rights reserved.
  • Page 118 700-43424-xx – outside of outside table legs, 700-43423-xx- inside of inside legs. Do not install the center panel 700-43425-xx at this time. Table Top A (700-42477-01) Table Top B (700-42476-01) Table Top C (700-42478-01) 700-43423-xx 700-43004-xx 700-43424-xx 700-43424-xx 700-43422-xx Page 118 © 2015 Cisco Systems, Inc. All rights reserved.
  • Page 119 Completing Installation of the First Row Table Install the cable runner retainer 700-44724-xx using 6x M6x10mm black screws 69-2815-xx. Table Top A (700-42477-01) Table Top B (700-42476-01) Table Top C (700-42478-01) 700-44724-xx 8x 69-2815 Page 119 © 2015 Cisco Systems, Inc. All rights reserved.
  • Page 120 Table Top B (700-42476-01) Table Top C & 700-42945-xx (700-42478-01) 2x 69-2815 (systems with optional 42-inch auxiliary displays only) Page 120 © 2015 Cisco Systems, Inc. All rights reserved.
  • Page 121 700-43425-xx to the slots located on the front cable management panel. Move the panel slightly up and over the legs, then move it into position. Table Top A (700-42477-01) Table Top B (700-42476-01) Table Top C (700-42478-01) 700-43425-xx Page 121 © 2015 Cisco Systems, Inc. All rights reserved.
  • Page 122 Install and secure the cable center/mute button cover 700-45410-xx to the underside of the tabletop assembly using 5x M4x10mm black screws (69-2821-xx). Table Top A (700-42477-01) Table Top B (700-42476-01) Table Top C (700-42478-01) 700-45410-xx 5x 69-2821-xx Page 122 © 2015 Cisco Systems, Inc. All rights reserved.
  • Page 123 Measure from the sides of the table to the sides of the endpoint structure. Both sides should be aligned and even with the structure. Table Top A (700-42477-01) Table Top B (700-42476-01) Table Top C (700-42478-01) Page 123 © 2015 Cisco Systems, Inc. All rights reserved.
  • Page 124 3x Turnaround microphone bars 74-12552-xx* * The packaging includes the mic bar and the center cap. Do not throw the 69-2677-xx, includes 3x Jumper Cord, 2 meter, 37-0994-xx small round caps away. Page 124 © 2015 Cisco Systems, Inc. All rights reserved.
  • Page 125 Installing the Second Row Table (IX5200 Only) Preinstallation requirement: Plan for trenching for cables in the room using the following diagram. Page 125 © 2015 Cisco Systems, Inc. All rights reserved.
  • Page 126 Turn the 7x table legs (1x far left 800-44198-xx, 1x far right 800-44197-xx, 5X inside legs 800-44200- xx) upside down. Adjust the levelers until there is 1 inch (25mm) between the bottom of the leg and the base of the foot. 25mm (1”) Page 126 © 2015 Cisco Systems, Inc. All rights reserved.
  • Page 127 NOTE: This is shown from the front, so right and left are reversed. 800-42717-xx 5x 800-44200-xx (all inside legs) 800-42715-xx 800-44197-xx 800-44198-xx Page 127 © 2015 Cisco Systems, Inc. All rights reserved.
  • Page 128 Connect the far-right cable management assembly 800-42715-xx to the far-right table leg 800-44197- xx and the second-from right table leg 800-44200-xx by inserting 6x M8x16mm screws 69-2802-xx into each leg. 800-44197-xx 800-42715-xx 800-44200-xx 6x 69-2802-xx Page 128 © 2015 Cisco Systems, Inc. All rights reserved.
  • Page 129 Tip: Keep the structure centered behind the first row table, and use the measurements in the next slide to keep it the correct distance from the first row table. 800-42715-xx 800-42717-xx 800-44198-xx Page 129 © 2015 Cisco Systems, Inc. All rights reserved.
  • Page 130 1535 mm 1535 mm 1542 mm 1542 mm Align the center of the center table leg with the center of the mute button on the front row table Page 130 © 2015 Cisco Systems, Inc. All rights reserved.
  • Page 131 Connect the 2x switch bracket 700-44758-xx to the switch with 2x 10-32 screws 69-2818-xx. Attach the 2x switches, 2x MCs, and 2x PDUs to the structure using 12x M6 nuts 49-100235-xx. 2x 800-40951-xx 2x WS-C2960C-8PC-L 12x 49-100235-xx 2x 74-8655-xx 2x 700-44758-xx Page 131 © 2015 Cisco Systems, Inc. All rights reserved.
  • Page 132 14x M4x12mm 69-2801-xx screws. NOTE: This drawing is shown from the front - left and right are reversed. 700-45430-xx 700-45430-xx 700-45431-xx 700-45431-xx 700-45431-xx 700-103476-xx 700-103477-xx 2x 69-2801-xx 700-103477-xx 2x 69-2801-xx 700-45430-xx Page 132 © 2015 Cisco Systems, Inc. All rights reserved.
  • Page 133 Align this notch on the outer second row table legs with the same notch on the outer first row table legs Page 133 © 2015 Cisco Systems, Inc. All rights reserved.
  • Page 134 Use 2x blanking plates 700- 45421-xx for the two outside legs as shown. 5x Inside legs 2x outside legs 700-45421-xx 700-47772-xx 2x Power/Ethernet 700-47772-xx 1x Power/Ethernet Modules 8x 4-40 nuts Modules 8x 4-40 nuts Page 134 © 2015 Cisco Systems, Inc. All rights reserved.
  • Page 135 Add one additional jumper cable to each table leg (to facilitate any replacement procedures). Insert extra jumper cable and route behind power connector - note jumper connections Assembled power/Ethernet connectivity modules Page 135 © 2015 Cisco Systems, Inc. All rights reserved.
  • Page 136 MCs. Use the cabling diagram for complete information. • 12x Ethernet cables for the 12 Ethernet participant laptop connections • 12x power cables for the 12 power connections for participants Page 136 © 2015 Cisco Systems, Inc. All rights reserved.
  • Page 137: Cable Routing, Left

    Installing the Second Row Table (IX5200 Only) Cable Routing, Left Page 137 © 2015 Cisco Systems, Inc. All rights reserved.
  • Page 138 Installing the Second Row Table (IX5200 Only) Cable Routing, Center Page 138 © 2015 Cisco Systems, Inc. All rights reserved.
  • Page 139: Cable Routing, Right

    Installing the Second Row Table (IX5200 Only) Cable Routing, Right Page 139 © 2015 Cisco Systems, Inc. All rights reserved.
  • Page 140 6x 69-2817-xx. Choose one of two mounting points using the four holes in 700-46613-xx 3x 69-2803-xx (not shown, installed from back of system) 700-46613-xx 700-46612-xx Tapered edge points toward exit path for cables Page 140 © 2015 Cisco Systems, Inc. All rights reserved.
  • Page 141: Cable Routing For The Downspout

    Installing the Second Row Table (IX5200 Only) Cable Routing For the Downspout Page 141 © 2015 Cisco Systems, Inc. All rights reserved.
  • Page 142 Tip: There are letters on the edges of the table. Match the letters on the underside of the tables to build the table correctly. 700-45241-xx 700-45240-xx 700-103970-xx 700-103971-xx 700-45242-xx 700-45239-xx Numbering on table edges Page 142 © 2015 Cisco Systems, Inc. All rights reserved.
  • Page 143 3x regular mic bars, and and 3x turnaound mic bars. Turnaround mic bars have a red label on the underside. Turnaround mics 74-12552- xx- note red label on underside 74-12552-xx 74-12199-xx 74-12199-xx 74-12552-xx 6x 74-12200-xx 74-12552-xx 74-12199-xx Page 143 © 2015 Cisco Systems, Inc. All rights reserved.
  • Page 144 Secure the front panel covers to the cable management assemblies using 12x M6x10mm screws 69-2803-xx. 3x 700-43005-xx 700-43424-xx 700-43424-xx 3x 700-43502-xx 12x 69-2803-xx 6x 700-43426-xx - right inside 6x 700-43427-xx - left inside Page 144 © 2015 Cisco Systems, Inc. All rights reserved.
  • Page 145 Attach the mute button covers to the underside of the second row table to the underside of the tabletop assemblies using 4x M4x10mm black screws 69-2817-xx for each cover. 24x 69-2817-xx 3x 700-45426-xx 3x 700-45427-xx Page 145 © 2015 Cisco Systems, Inc. All rights reserved.
  • Page 146 Perform a final height check and make sure that the first and second row tables are the same height. 1408 mm 1408 mm 1412 mm Laser level Page 146 © 2015 Cisco Systems, Inc. All rights reserved.
  • Page 147: Installing The Outer Structure Panels And Trim

    1x each top and bottom fascia (74-12905-xx top, 74-13021-xx bottom) Camera lens hood 800-43478-xx 4x rear PET plastic panels: left 800-41100-xx, right 800-41099-xx, top 800-41097-xx and bottom 800-41098-xx Rear cable runner cover 700-43380-xx Page 147 © 2015 Cisco Systems, Inc. All rights reserved.
  • Page 148 Slot (engages with guide pin) Guide block 800-41092-xx Installed center cabinet (from back of system) Page 148 © 2015 Cisco Systems, Inc. All rights reserved.
  • Page 149 1. The trim joint is connecting to the trim. 2. The guide pins in the frame align with the notches in the cabinet. 3. The lap joint overlaps correctly between the side and center cabinets. 800-41093-xx 700-43281-xx Guide blocks and slots Lap joint Back of system Guide pins Page 149 © 2015 Cisco Systems, Inc. All rights reserved.
  • Page 150 Tip: If you cannot eliminate the gaps, make the gaps even on both sides. Table Top A (700-42477-01) Table Top B 800-41094-xx (700-42476-01) Table Top C (700-42478-01) Page 150 © 2015 Cisco Systems, Inc. All rights reserved.
  • Page 151 Installing the Outer Structure Panels and Trim Install the lower corner cabinets (800-41096-xx left, 800-41095-xx right). Table Top A (700-42477-01) Table Top B (700-42476-01) Table Top C (700-42478-01) 800-41096-xx 800-41095-xx Page 151 © 2015 Cisco Systems, Inc. All rights reserved.
  • Page 152 (700-42477-01) Table Top B (700-42476-01) 4x 69-2797-xx & 69-2842-xx Align tab with trim Table Top C Loosen these 2x Connect magnet (700-42478-01) screws in the cabinets to structure Page 152 © 2015 Cisco Systems, Inc. All rights reserved.
  • Page 153 After you complete this alignment, tighten the 4x screws (2x in each place) shown in the circles in the illustration. Note that these screws are hidden. Table Top A (700-42477-01) Table Top B (700-42476-01) Table Top C (700-42478-01) Page 153 © 2015 Cisco Systems, Inc. All rights reserved.
  • Page 154 Installing the Outer Structure Panels and Trim Install the bottom trim pieces. Table Top A (700-42477-01) Table Top B (700-42476-01) Table Top C (700-42478-01) 800-41302-xx 800-41301-xx 800-42208-xx Page 154 © 2015 Cisco Systems, Inc. All rights reserved.
  • Page 155 69-2797-xx at the far right and left of the bottom trim. (700-42477-01) Table Top B (700-42476-01) Table Top C (700-42478-01) 800-41302-xx Loosen screws on all four brackets 2x 69-2797-xx so that bracket can be adjusted Page 155 © 2015 Cisco Systems, Inc. All rights reserved.
  • Page 156 Table Top A (700-42477-01) Table Top B (700-42476-01) Table Top C (700-42478-01) 2x 69-2797-xx Page 156 © 2015 Cisco Systems, Inc. All rights reserved.
  • Page 157 After assembly, level and align the left and right trim pieces. Slide the trim pieces outward (to the sides) to close the gap with the trim on the lower cabinets. Table Top A (700-42477-01) Table Top B (700-42476-01) Table Top C (700-42478-01) 800-42208-xx Page 157 © 2015 Cisco Systems, Inc. All rights reserved.
  • Page 158 Install and tighten 4x Black M4 X 12mm long screws with external lock washer 69-2797-xx. Tighten all trim pieces. Table Top A (700-42477-01) Table Top B (700-42476-01) Table Top C (700-42478-01) 4x 69-2797-xx 800-41301-xx Page 158 © 2015 Cisco Systems, Inc. All rights reserved.
  • Page 159 Insert the 2x bottom trim plates 700-102967-xx (one between the left and center trim assembly, and one between the right and center trim assembly) into the trim assemblies. Table Top A (700-42477-01) Table Top B (700-42476-01) Table Top C (700-42478-01) 2x 700-102967-xx Page 159 © 2015 Cisco Systems, Inc. All rights reserved.
  • Page 160 2x pin 700-47278-xx and 2x clip 52-100131-xx (1 on each side). Table Top A (700-42477-01) 2x 700-47278-xx Table Top B (700-42476-01) Table Top C (700-42478-01) 800-42131-xx 2x 52-100131-xx Page 160 © 2015 Cisco Systems, Inc. All rights reserved.
  • Page 161 Table Top A (700-42477-01) Table Top B (700-42476-01) Table Top C (700-42478-01) Hole 800-42131-xx Trim-viewed from back Page 161 © 2015 Cisco Systems, Inc. All rights reserved.
  • Page 162 Velcro attach, then attach the trim to the Velcro, magnets, and studs between the center and right displays. Table Top A (700-42477-01) Table Top B (700-42476-01) Table Top C (700-42478-01) 800-42131-xx Attachment points Studs Page 162 © 2015 Cisco Systems, Inc. All rights reserved.
  • Page 163 Place the pin in the horizontal display trim into the hole in the endpoint structure. Adjust the trim until both sides are even. Table Top A (700-42477-01) Hole Table Top B (700-42476-01) Table Top C (700-42478-01) 800-42131-xx Trim-viewed from back Page 163 © 2015 Cisco Systems, Inc. All rights reserved.
  • Page 164 Table Top A (700-42477-01) Left Table Top B upper (700-42476-01) Left display cabinet trim Left vertical Table Top C trim (700-42478-01) Display spools Horizontal display trim Page 164 © 2015 Cisco Systems, Inc. All rights reserved.
  • Page 165 This procedure aids in stability while you assemble the bottom fascia, but still allows you to swing the fascia sides back to the display structure. View from top of system 74-13021-xx Page 165 © 2015 Cisco Systems, Inc. All rights reserved.
  • Page 166 Table Top A (700-42477-01) 74-13021-xx Endpoint Structure Table Top B (700-42476-01) Table Top C (700-42478-01) Frame slots for alignment lip and Vertical alignment lip in bottom fascia magnets in bottom fascia Page 166 © 2015 Cisco Systems, Inc. All rights reserved.
  • Page 167 Table Top A (700-42477-01) Table Top B Slot engages with tab - note (700-42476-01) round magnets on fascia Table Top C (700-42478-01) 74-13021-xx Bracket engages with hook Page 167 © 2015 Cisco Systems, Inc. All rights reserved.
  • Page 168 Unfold the bottom fascia, one side at a time, and insert the tabs in the side receiving slots until the magnets in the fascia engage with the display structure. Table Top A (700-42477-01) Table Top B (700-42476-01) Table Top C (700-42478-01) Page 168 © 2015 Cisco Systems, Inc. All rights reserved.
  • Page 169 The four circled screws with plastic washer should provide adequate movement without loosening the screws. Tighten the screws and replace the fascia after final adjustment. Table Top A (700-42477-01) Table Top B (700-42476-01) Table Top C (700-42478-01) Page 169 © 2015 Cisco Systems, Inc. All rights reserved.
  • Page 170 Table Top B (700-42476-01) Table Top C (700-42478-01) 2x 700-47507-xx, 700-47506-xx, or 700-47505-xx - choose the one that fits best between the gaps 2x 69-2793-xx Fascia removed in this illustration for clarity Page 170 © 2015 Cisco Systems, Inc. All rights reserved.
  • Page 171 Align the top fascia vertically. The upper lip of the top fascia rests in the sheet metal Table Top A shelf in the display frame that is created by the horizontal cross bars. (700-42477-01) Table Top B (700-42476-01) Table Top C (700-42478-01) 74-12905-xx Frame shelf Page 171 © 2015 Cisco Systems, Inc. All rights reserved.
  • Page 172 Unfold the top fascia one side at a time, engaging the magnets and sheet metal tabs with the upper alignment points in the fascia. Table Top A (700-42477-01) Table Top B (700-42476-01) Table Top C (700-42478-01) Page 172 © 2015 Cisco Systems, Inc. All rights reserved.
  • Page 173 Install the camera lens hood 800-43478-xx around the camera by placing it into the holes in the upper fascia and the endpoint structure. 800-43478-xx Table Top A (700-42477-01) Table Top B (700-42476-01) Table Top C (700-42478-01) Page 173 © 2015 Cisco Systems, Inc. All rights reserved.
  • Page 174 Table Top A in the panel to the slots in the frame and making sure that the panel is fully seated. (700-42477-01) Table Top B (700-42476-01) Table Top C (700-42478-01) 800-41097-xx 800-41098-xx Page 174 © 2015 Cisco Systems, Inc. All rights reserved.
  • Page 175 700-43380-xx over the rear of the cable cap, noting the pins on the rear part of the cover. Table Top A (700-42477-01) Table Top B (700-42476-01) 800-41100-xx Table Top C (700-42478-01) 700-43380-xx 800-41099-xx Page 175 © 2015 Cisco Systems, Inc. All rights reserved.
  • Page 176: Installing The Optional 42-Inch Auxiliary Display

    • #3 Phillips Driver • “Stubby” (short) #3 Phillips driver, or Phillips driver • 42-inch display bracket, 700-47588-xx with ratcheting wrench • 8x M6x16mm screws, 69-100199-xx • Optional: 1x M4x12mm screw (not included) Page 176 © 2015 Cisco Systems, Inc. All rights reserved.
  • Page 177 Tip: there is a hole in the top of the bracket, press in this hole with your thumb to separate the two pieces. Some force may be required. Page 177 © 2015 Cisco Systems, Inc. All rights reserved.
  • Page 178 Connect the lower half of the bracket piece to the cable runner using 4x M6x16mm screws 69-100199-xx. Note the cables running through the hole in the bracket. Take care not to mar the lower fascia or the cable runner. 69-100199-xx Page 178 © 2015 Cisco Systems, Inc. All rights reserved.
  • Page 179 Installing the Optional 42-Inch Display Remove the display from its packaging, and install the other half of the bracket onto the rear of the display using 4x M6x16mm screws 69-100199-xx. Page 179 © 2015 Cisco Systems, Inc. All rights reserved.
  • Page 180 Tip: there are four metal studs (two on each side) that protrude from the display bracket. Make sure that the studs go into the two slots on each side of the cable runner bracket. Slots Studs (hidden here) Slots Page 180 © 2015 Cisco Systems, Inc. All rights reserved.
  • Page 181 Rock the display and bracket backwards until the tab in the display bracket joins with the slot in the cable runner bracket. Power switch Power DVI and power connectors Page 181 © 2015 Cisco Systems, Inc. All rights reserved.
  • Page 182 Note the use of a “stubby” screwdriver. A Phillips driver and a ratcheting wrench may also be used. Stubby screwdriver or Phillips driver with ratcheting wrench Bracket pivots on this screw Page 182 © 2015 Cisco Systems, Inc. All rights reserved.
  • Page 183 Installing the Optional 42-Inch Display Optional: Attach an M4x12mm screw (not included) to join the brackets together. M4 screw (not shown) Page 183 © 2015 Cisco Systems, Inc. All rights reserved.
  • Page 184: Cable Routing Diagrams

    Cable Routing Diagrams Cable Routing Diagrams This chapter includes the cable routing diagrams for the system. Page 184 © 2015 Cisco Systems, Inc. All rights reserved.
  • Page 185 Cable Routing Diagrams Page 185 © 2015 Cisco Systems, Inc. All rights reserved.
  • Page 186 Cable Routing Diagrams Page 186 © 2015 Cisco Systems, Inc. All rights reserved.