LYNX Touch Installation and Setup Guide
Programming the Control
Program System Settings (Continued)
SCREEN
Backlight Timeout
No
Quick Arm
Yes
Quick Exit
Yes
Restart Exit Time
Yes
Force Bypass
No
Exit Warning
Yes
Auto Stay Arming
Yes
Lack of Usage Notify
Disabled
Power-Up In Previous
Yes
Display Alarm Cancel
Yes
Display Exit Time
Yes
Cross Zone Delay
None
Cross Zone 1
Disabled
Cross Zone 2
Disabled
Select "Backlight Timeout". The System toggles between No and 30 Seconds.
Select "Quick Arm". The System toggles between Yes and No.
Select "Quick Exit". The System toggles between Yes and No.
Select "Restart Exit Time". The System toggles between Yes and No.
SIA: The L5200/L7000 default is "Yes".
Select "Force Bypass". The System toggles between Yes and No.
UL installations: must be NO (no forced bypass)
Select "Exit Warning". The System toggles between Yes and No.
SIA: The L5200/L7000 default is "Yes" and is not selectable.
Select "Auto Stay Arming". The System toggles between Yes and No.
SIA: The L5200/L7000 default is "Yes".
Select "Lack of Usage Notify". The System scrolls between the following options:
Disabled
1 Day
90 Days
7 Days
180 Days
27 Days
365 Days
Select "Power-Up In Previous". The System toggles between Yes and No.
Note: If the previous state was Armed Away or Stay, the system will not respond to sensor changes for
1 minute. This allows time for sensors such as PIRs to stabilize.
UL installations: must be Yes (power up in previous state)
SIA: The L5200/L7000 default is "Yes" and is not selectable.
Select "Display Alarm Cancel". The System toggles between Yes and No.
Select "Display Exit Time". The System toggles between Yes and No.
Select "Cross Zone Delay". The System toggles between the following:
None
30 Seconds
1 Minute
90 Seconds
2 Minutes
3 Minutes
4 Minutes
Note: Cross zoning cannot be used in conjunction with APL.
Select "Cross Zone 1". The System toggles between the following:
Disabled
Note: If Cross Zone Delay is enabled the system will display the zones that are programmed
with the following Zone Types: Day/Night, Interior Follower and perimeter.
Select "Cross Zone 2". The System toggles between the following:
Disabled
Note: If Cross Zone Delay is enabled the system will display the zones that are programmed
with the following Zone Types: Day/Night, Interior Follower and perimeter.
ACTION
- 50 -