  • Page 1 INSTALLATION MANUAL MIM-D00 (Data Management Server) DB98-29919A(1)
  • Page 2: Safety Precautions

    Safety Precautions This installation manual describes how to install the DMS. For installation of other optional accessories, refer to the appropriate installation manual. R ead carefully this installation manual before   WARNING installation and check if the DMS is installed correctly after installation.
  • Page 3: Table Of Contents

    Contents  AFETY RECAUTIONS .............. EFORE NSTALLING THE ............ CCESSORIES .................. RODUCT ESIGN ................ IMENSIONS ..............RODUCT  YSTEM RCHITECTURE .............. OMPATIBLE EVICES .............. NSTALLING THE ..............DMS E  XTERNAL ISPLAY .............  ETTING THE OMPUTER NVIRONMENT ........
  • Page 4: Before Installing The Dms

    PC is on. ETWORK RELATED EQUIPMENTS  Network equipments such as HUBs and network cables are not provided by Samsung. NSTALLATION NOTICE  The DMS is recommended to be wall-mounted to prevent damage to the product and for safety issues.
  • Page 5: Accessories

    Accessories M4X16 Screw(5) DMS(1) Cable Tie (2) Cable Clamp(3) Rubber Hook(4) User's manual(1) Installation manual(1) Caution The DMS must be installed by a trained installer.  Ensure the main power is turned off before installing  the DMS. The power cable and the communication cable must ...
  • Page 6: Product Dimensions

    Product Dimensions Unit : mm Serial Port Power Input LAN Port 101010 Reset Button  Installation Method Fix the provided screws to the wall and use the four holes on the back of the DMS to hang the DMS on the wall.
  • Page 7: System Architecture

     C onnect one power meter to N number of outdoor units. Make sure the power meter capacity is greater than the total capacity of the outdoor units. Note  P roducts with ‘*’ are not Samsung products and must be purchased separately.
  • Page 8: Compatible Devices

    Meter compatible power meters) Note  P roducts with ‘* ’ are not Samsung products and must be purchased separately. (Only selected power meters may be used for protocol compatibility issues.) Maximum Devices attachable The maximum number of devices attachable to the DMS is as follow: Devices Max.
  • Page 9: Installing The Dms

    Installing the DMS Connecting the Centralized Controller The centralized controllers must be installed to control the indoor units. Loosen the two screws on the bottom of the DMS front cover. Hold the bottom two sides of the DMS and push upwards to slide open the cover.
  • Page 10 Installing the DMS (Continued) Connecting the SIM I/M The SIM I/M must be used for the power distribution function. Loosen the two screws on the bottom of the DMS front cover. Hold the bottom two sides of the DMS and push upwards to slide open the cover.
  • Page 11 Connect the LAN cable to the J6 terminal of the DMS. Close the case cover after making sure the power cable is not pressed. Peak Power I/M Assemble the cover as shown in the picture to avoid communication cable POWER CABLE exposure of the stripped wires.
  • Page 12 Installing the DMS (Continued) DMS PCB Option Switches Reset Switch (SW01) : Resets the DMS when the DMS stops operating. (Pressing the reset switch will delete all current data. The switch must only be operated by the installer.) DIP Switch(SW3) : Used for setting the DI mode.
  • Page 13 Using the DI external contact signal control (Optional) DIP Switch (SW03) : Use only for external contact signal control. DIP Switch Pattern Control Details No response to the external contact signal control. Pattern OFF OFF OFF OFF (Factory default setting) Used for emergency cases such fire.
  • Page 14: Dms External Display

    DMS External Display LED Status Display Power display.  Power (Red) The power display is on when there’s a power input. Flickers every second if the CPU is operating normally.  CPU Alive(Yellow) (The CPU is in waiting status and the CPU Alive display is off initially when powered up.) Internet cable connection status display.
  • Page 15: Setting The Computer Environment

    Setting the Computer Environment The following device and accessory is needed:  Computer with a LAN Card  *Cross Cable or a HUB Setting the computer environment.  Must have Internet Explorer 6.0 or above installed. Please install the internet explorer 6.0 or above through Windows Update ...
  • Page 16 Setting the Computer Environment (Continued) Setting the computer environment to access the DMS for the first time.  All the environment of the DMS is set by connecting to the DMS. In order to access the DMS, the computer environment must be set as follow: Choose one of the two methods to access the DMS.
  • Page 17 Connect to the internet. Run the internet explorer and type in the following address. http://192.168.0.2 If the connection is successful, the following front page will load. The DMS will prompt for a user ID and a password as shown above. The factory default user setting is as follow: admin 1234...
  • Page 18 Setting the Computer Environment (Continued)  T he following screen is displayed if the login is successful. Click on SYSTEM ENVIRONMENT.
  • Page 19  C lick on the ‘Edit’ button to change the language settings. (Default:English) The system will start up automatically once the language is set.  C lick on the ‘Edit’ button to change the DMS network settings. The system will start up automatically once the settings are saved. ...
  • Page 20 Setting the Computer Environment (Continued) Tracking  C lick on the tracking button once the environment is set. The above screen will be displayed.  S elect either the group mode tracking or the room mode tracking.  Group mode tracking: Control the indoor units according to the RMC address.
  • Page 21 The following screen is display if tracking is successful.  C lick on the edit button to change the names of the indoor units and the centralized controllers. The basic settings for the internet control is set. Please refer to the user manual for detailed information on internet control.
  • Page 22: Appendix

    ( External circuit may be built for display using the 12V  (Digital Output) output) Equivalent to the ‘Error’ LED on the DMS external display. Serial communication for environment setup purpose.  port Note Consult Samsung Electronics when building an external circuit for display.
  • Page 23 DI(Digital Input) Circuitry (Optional) Pattern 2 (May be used for connection with a fire sensor) ��� Emergency Stop/Resume Operation ���� ���� No Connection Pattern 3 ��� Run/Stop A/C ���� Enable/Disable remote control ���� Pattern 4 (Pulse signal control) ��� ���� Stop ����...
  • Page 24: Setting The Ip Address

    Appendix (Continued) Setting the IP Address When using DSL connection 1) Using a private IP : used if the internet control is not needed and the DMS is controlled only from one place.  Connecting the DMS and the controller 1:1 SNET-i *Cross Cable Private IP : 192.168.0.2...
  • Page 25 IP terms explanation Public IP Static IP Dynamic IP Private IP Static IP Dynamic IP The DMS requires an IP address to be connected to the internet and to allow computers to access the DMS.  Public IP Public IP addresses are IP addresses that are visible to the public.
  • Page 26 Appendix (Continued) IP Setup Error Initial connection error (occurs only when using a private IP)  A number of DMS’ are connected on the same network The default factory IP setting of all the DMS’ are the same and when they are connected on the same network, the IP address of the DMS’...
  • Page 27 Installation Errors Check points when tracking fails and the installation information of the indoor and outdoor units are not available. Check the centralized controller and transmitter models. Check the communication status between the centralized controller and the transmitter. Devices If the communication is normal If the communication fails Centralized The indoor units are controlled...