  • Page 1 USER’S MANUAL MIM-D00 (Data Management Server) DB98-29777A(4)
  • Page 2: Safety Precautions

    Safety Precautions • Before using the DMS, read carefully these instructions. • After reading the instructions, keep this user's manual in a handy and safe place. If a user is changed, you must hand over the manuals. • Never attempt to install the air conditioning system or to move the DMS by yourself. WARNING CAUTION D o not attempt to install or repair this DMS by yourself.
  • Page 3: Table Of Contents

    Contents General Description ... 4  NTRODUCTION OF DMS S ... 4  DVANTAGES OF YSTEM ... 5  ERMS Main Function  NTERFACE WITH PPER EVEL ONTROLLER ... 6  RROR ISTORY ... 7  ET AND CHEDULE  NTEGRATED OWER ISTRIBUTION...
  • Page 4: General Description

    General Description DMS (D NTRODUCTION OF The DMS is an Internet based device for central management of Samsung system air-conditioners. It supports LAN & WAN and operates 24 hours without a separate PC. DMS S DVANTAGES OF YSTEM The DMS provides the following advantages: ...
  • Page 5: Terms

    ERMS   The abbreviation of Data Management Server.   PPER ONTROLLER It means S-NET Series, a local controller of the DVM system. S-NET 3, S-NET mini and S-NET i are linked to a DMS.   ENTRALIZED ONTROLLER A device that controls 16 groups of the DVM air conditioner.
  • Page 6: Main Function

    Main Function Interface with Upper Level Controller The DMS receives control data from the upper level controller and sends the received data to the lower level system. The upper level controllers of the DMS are the S-NET series and the connectible S-NET series are S-NET 3, S-NET i and S-NET mini.
  • Page 7: Set And Run Schedule

    Set and Run Schedule The schedule function of the DMS can be set through the Web or using the upper level controller. Weekly/Yearly schedules can be set and the following information can be assigned to each schedule: Item Schedule Starting and ending date of a schedule Period Set an exception day within a schedule period to Exception Day...
  • Page 8: Save Integrated Power Distribution Data

    Main Function (Continued) Save Integrated Power Distribution Data Overview  The DMS calculates and distributes the power consumed by each indoor unit by receiving the total power usage from the watt-hour meter interface modules (SIM) and taking into account the operation status of the indoor units. ...
  • Page 9: Time Segmentation

    Time Segmentation  Time segmentation is used to divide 24 hours into different sections and to distribute power according to each section.  This function is used when the power consumption fee is different according to different time slots or when a building is charged differently depending on the consumption time.
  • Page 10: Using The Dms Through The Web

    Using the DMS through the Web Setting the Web Environment nstall JRE 1.3.1 or later version  Java Runtime Environment 1.3.1 or a later version must be installed on the PC. JRE is installed automatically if the PC is connected to the Internet and when the DMS is accessed for the first time.
  • Page 11: Login

    Login Function Details  Login allows only authorized users to access the web page.  There is no limit on the number of users that can access the DMS at the same time, however, less than 5 users are recommended for access speed reasons.
  • Page 12: Monitoring And Control

    Using the DMS through the Web (Continued) Monitoring and Control Function Details  On this screen users can monitor the operation status of all indoor units and control each indoor unit. (But, if the ERV system is installed, can check the whole ERV control status.) Monitoring and Control The status of all indoor units can be viewed from the ‘Monitor all indoor units.
  • Page 13 Select and click on the indoor unit and the background color of the indoor unit is changed to green. The operation status of the selected indoor unit is displayed on the upper part. Displayed items are as follow: Selected indoor unit address Error Power Celsius(°C)
  • Page 14 Using the DMS through the Web (Continued) Enable/Disable Remote Control.  When pressing the  When pressing the disappear.  If remote control LEVEL1 is set on upper level controller, selected indoor unit will be underlined. Select All/Clear all.  The simultaneous control of whole installed indoor units is possible. ...
  • Page 15 [Current Temperature] Selection.  When selecting the check box, display the current temperature of the whole installed indoor units.  In order to return to the monitoring screen, select again the [Current Temperature]. Emergency Stop status button is displayed in red if the DMS is currently in the emergency stop status.
  • Page 16: Monitoring And Control (Erv System)

    Using the DMS through the Web (Continued) Monitoring and Control (ERV System) Function Details  On this screen users can monitor the operation status of all ERVs and control each ERV. Monitoring and Control The status of all ERVs can be viewed from the ‘Monitor all indoor units.
  • Page 17 Select and click on the ERV and the background color of the ERV is changed to green. The operation status of the selected ERV is displayed on the upper part. Displayed items are as follow: Selected indoor unit address Error Power Mode Set Fan Speed...
  • Page 18 Using the DMS through the Web (Continued) Enable Remote Control/Disable Remote Control.  When pressing the remote control in each room and can control the ERV only on the DMS webpage screen.  When ending the DMS after selecting the screen, cannot use the ERV in each room.
  • Page 19 [Current Temperature] Selection.  When selecting the check box on the ERV system, display with “- -”.  In order to return to the monitoring screen, select again the [Current Temperature.] Emergency Stop status button is displayed in red if the DMS is currently in the emergency stop status.
  • Page 20: View Error History

    Using the DMS through the Web (Continued)  View Error History Function Details The DMS users can view and delete error history of the DVM  system. The DMS saves up to 256 errors. Viewing the Error History All error history can be checked from the ‘View Error History’...
  • Page 21: Set, Run And View Schedule

    Set, Run and View Schedule Function Details Users can set, edit, and delete schedules for controlling the DVM  system. Using the Schedule Function   The Schedule List screen shows all current schedule information saved in the DMS. On the schedule screen, a schedule can be created, edited, viewed, and deleted.
  • Page 22 Using the DMS through the Web (Continued)   Adding a New Schedule    On the Create New Schedule screen, users can set the Schedule Name, Schedule Period, Applied Indoor Unit, and Event. For the event, users can set the Repeat or not, Day, On Time, Off Time, Temperature, Mode, ERV Mode and Remote Control Allow or not.
  • Page 23 When pressing the ‘Select indoor unit’ button from the users can select the schedule indoor unit. Users can set one of schedule repetition or not, which are every week, every day, and one day from the drop down menu . If setting to one day, assign the same date of ...
  • Page 24: Setting And Viewing The Power Distribution Function

    Using the DMS through the Web (Continued)  Setting and Viewing the Power Distribution Function Function Explanation Users can set, inquire, and edit the information of power  distribution section. Refer to pg. 4 for more information on the Power Distribution ...
  • Page 25  Section A and Section B are existed in 2 Sections. Can inquire and set the border time between Section A and Section B. When pressing the ‘Save’ button from the border time from the area , set time is adopted. If the border ...
  • Page 26: Setting And Viewing The Power Distribution Environment

    Using the DMS through the Web (Continued) Setting and Viewing the Power Distribution Environment Function Explanation Users can view or edit the connection between the indoor units  and assigned watt-hour meter. DMS will distribute power based on the information which has been set up from this menu. Check the address and the channel on the SIM transmitter that is connected to the watt-hour meter.
  • Page 27 Check the indoor/outdoor units connected to the watt-hour meter. Check the SIM transmitter channel (watt-hour meter).  If the indoor unit power is supplied from the outdoor unit, set the ‘Outdoor SIM ch. ’ only. ( ‘Outdoor SIM ch. ’ signifies the watt-hour meter connected to the outdoor unit.) ...
  • Page 28 Using the DMS through the Web (Continued) Note  Indoor/Outdoor unit SIM channel setting - If there is SIM transmitter connected to the DMS, user can set up the SIM channel. - User will not have to inspect the watt-hour meter since power distribution will be done automatically.
  • Page 29: Inquire Power Distribution Result

    Inquire Power Distribution Result Function Explanation Users can inquire operation breakdowns and power usage by  indoor units that is saved in the DMS. Inquiring the result   Total Indoor units (by period) Select ‘Total Indoor units (by period)’ in power consumption and the rate by period for all the indoor units.
  • Page 30 Using the DMS through the Web (Continued)    Individual Indoor unit (by period) Select ‘Individual indoor units (by date)’ in power consumption and the running rate by date for individual indoor unit. Select the indoor unit to check in ( If the DMS is set to group mode and one group has more than two indoor units, each individual indoor unit will be checked.)
  • Page 31: Viewing Power Distribution Result

    Viewing Power Distribution Result Click ‘SETUP FOR POWER DISTRIBUTION’ on the DMS web page. When the Virtual channel for the Indoor/Outdoor unit is set, above screen will appear. Select the time period and click ‘calculation’ to display the result. ...
  • Page 32 Using the DMS through the Web (Continued) Check the result of power distribution.  Click ‘Search’ to re-enter the power usage for each channel.  Click ‘Save As File’ to save the result as excel file.  Select ‘rate’ to check the result of power distribution in rate.
  • Page 33: Setting The Indoor Unit Restriction

    Setting the Indoor Unit Restriction Function Explanation The DMS users can restrict the indoor unit as cool only or heat  only. Setting the Indoor Unit Restriction Click ‘RESTRICTED INDOOR UNIT USE’ on the DMS web page. Click ‘Edit’ on the restricted indoor unit use screen. ...
  • Page 34 Using the DMS through the Web (Continued)   Click [] to select operation mode limit.  Users can select ‘None’ , ‘Cool only’ or ‘Heat only’ . Set the control mode.  If you set the control mode, indoor unit operating in limited operation mode will be automatically set to operate in pre-set control mode.
  • Page 35 Set lower limit temperature(Cool).  You can set the lower limit temperature by selecting ‘Cancel’ or ‘Apply’ .  If the desired temperature is lower than lower limit temperature when the indoor unit is operating in cool mode, DMS controls the desired temperature in the lower limit temperature.
  • Page 36 Using the DMS through the Web (Continued) Note  Mixed operation can occur even if you set control mode limit.  If the indoor unit with control mode limit is in mixed operation, DMS will solve the problem automatically by controlling it in control mode limit. CAUTION All indoor units under the same outdoor unit should be on same control mode ...
  • Page 37: Setting And Viewing The System Environment

    Setting and Viewing the System Environment Function Explanation The DMS users can set and view information related to the DMS  system installation and operation. (The installer must complete the system environment setup when installing the DMS.) System environment setup...
  • Page 38 Using the DMS through the Web (Continued) DMS Network Information Change the set information by inquiring the existing set network information from the DMS network information and clicking the ‘Edit’ button. If this information is changed, the DMS is restarted automatically. System Time Change the system time by inquiring the current system time and clicking the Edit button.
  • Page 39 Send error report email In order to send automatically to an e-mail when an error of the air conditioner is occurred, input an e-mail address, ID, password, and SMTP server information by clicking the ‘Edit’ button. When an input is completed, must check whether an e-mail is arrived to an inputted e-mail address by pressing the ‘Test’...
  • Page 40 Using the DMS through the Web (Continued)  Setting the Operation mode of A/C Running LED  Click ‘SYSTEM ENVIRONMENT’ on the DMS web page. Click ‘Edit’ on the Operation mode of A/C Running LED.  ‘Edit’ will change to ‘Save’ . Select the mode you wish to set.
  • Page 41: Log

    Function Explanation You can view the history of all the settings.  Check the setting history from the Log window.  DMS saves maximum 256 histories of each setting. If the number of history exceeds 256, DMS will delete the oldest history.
  • Page 42: Tracking

    Using the DMS through the Web (Continued) Tracking Function Details Tracking is the most initial stage that a DMS recognizes the DVM indoor/outdoor units.  When performing a Tracking, some information may be lost; thus, use with care. User can order the Retry of a Tracking and manage the name of devices on the Tracking information screen.
  • Page 43 When the Tracking Password Input window appears, enter the password. When the Tracking Confirm window appears, press ‘Confirm’ .  Tracking will start.
  • Page 44 Using the DMS through the Web (Continued) Notification with ‘Now tracking, please wait’ sign will appear.  Tracking may take from few seconds up to 3 minutes. Tracking time may differ depending on the number for controllers. When the tracking is done, press ‘Edit’ . ...
  • Page 45 Enter the name of the centralized controller and the indoor units. Press ‘Save’ .  Changed name of the centralized controller and the indoor unit will be saved on DMS.  ...
  • Page 46 Using the DMS through the Web (Continued) Note Do not run Tracking except for the following conditions:  A fter initial installation. - After initial installation, run Tracking for DMS to recognize the installation structure. - Make sure actual system air conditioner information matches the Tracking information displayed on DMS.
  • Page 47: User Management

    User Management Adding New User  Click ‘USER MANAGEMENT’ on the DMS web page. When User Management screen appears, enter user ID, Password and Description.  ID should be 4~10 letters long, starting with a alphabet and can be used with numbers. Click ‘Add’...
  • Page 48 Using the DMS through the Web (Continued)   Editing User Click ‘USER MANAGEMENT’ on the DMS web page. When User Management screen appears, select the user you wish to edit.  You can select number of users at once or select individual user.
  • Page 49 Deleting User  Click ‘USER MANAGEMENT’ on the DMS web page. When User Management screen appears, select the user you wish to delete.  You can select number of users at once or select individual user. Click ‘Delete’ .  If confirmation window appears, click ‘OK’ to delete selected user.
  • Page 50: Software

    Software License used in this product  This product uses softwares distributed under GPL and LGPL liscense. Therefore, you can receive the source code of GPL and LGPL used in this product by requesting the email address below. E-mail : oss.request@samsung.com  GPL Software ...
  • Page 51  Berkeley DB software is used in this product. The source code of Berkeley DB software can be received when request to the following email address or can be downloaded from the website. E-mail: oss.request@samsung.com  Berkeley DB software : db-3.2.9 ...