In-Skin Hub - NEC NEAX 2000 IPS Installation Manual

Internet protocol server installation procedure manual
Hide thumbs Also See for NEAX 2000 IPS:
Table of Contents

Advertisement

In-Skin HUB

(1)
Connection Outline
The In-Skin HUB card (PN-8ETIA) is used to accommodate switching HUB. PN-8ETIA card has 8-
ports 10BASE-T/100BASE-TX (Auto-negotiation fixed).
PZ-M675 card is mounted on PN-8ETIA card. PZ-M675 card is used to accommodate all 10BASE-
T/100BASE-TX ports on a PN-8ETIA card with Power over Ethernet (PoE).
BWB
The number of IP terminal that can be connected to the In-Skin HUB is as follows.
IP Terminal
Inaset
ITR-LC-1
ITR-240G-1
ITR-320C-1
DtermIP
ITR-8D-2
ITR-8D-3
ITR-16D-2
ITR-16D-3
ITR-16LD-3
ITR-32D-3
ITR-4D-1
Outline of Switching HUB Connection
PN-8ETIA card
PZ-M675 card
RJ45 Connector
LAN 7/8
PBX
LAN 5/6
LAN 3/4
LAN 1/2
:
MP
card
10BASE-T/100BASE-TX Cable
Number of IP Terminal
No. of IP Terminal (MAXIMUM)
2000 IPS
5
7
5
7
7
7
7
7
7
7
MAXIMUM 100 m (327.5 ft.)
IPSDM
2
5
2
4
4
4
4
4
4
4
– 201 –