Battery Connection - NEC NEAX 2000 IPS Installation Manual

Internet protocol server installation procedure manual
Hide thumbs Also See for NEAX 2000 IPS:
Table of Contents

Advertisement

BATTERY CONNECTION

TURN OFF AC POWER BEFORE CONNECTING BATTERIES.
1. 24 V batteries must be used in this system.
2. If battery terminals (+, –) come in contact with the module while connecting the battery cable
to the PZ-PW121/PZ-PW126 card, the PZ-PW121/PZ-PW126 card or the BWB may be bro-
ken. Therefore, you must perform work in accordance with the following steps when mount-
ing or removing the batteries.
(1)
When mounting batteries:
(a) Connect the battery cable to the batteries.
(b) Mount the batteries into the appointed position of the PIM or the BATTM.
(c) Connect the battery cable to the PZ-PW121/PZ-PW126 card.
(2)
When removing batteries:
(a) Disconnect the battery cable from the PZ-PW121/PZ-PW126 card.
(b) Remove the batteries from the PIM or the BATTM.
Recommended Battery
Internal Battery:
External Battery:
(BATTM)
WARNING
CAUTION
YUASA
type NPH-3.2-12
MATSUSHITA
type LCR-12V3.4NE
YUASA
type NP-24-12B
MATSUSHITA
type LCL-12V-24
– 129 –
CHAPTER 2 INSTALLATION

BATTERY CONNECTION

Continued on next page
NWA-008841-001 Rev.5.0
90ch2001.fm

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents