Easy Series (ICP-EZM2) | Installer Guide | 4.0 Programming
Item
Programming Item
Number
Test Report Hour
143
Test Report Minute
144
Test Report Day of
145
Week
146
Test Report Day of
Month
Restrict Confirmed
147
Alarm Memory
Arming
148
Beeps/Graduated
Annunciation
Wireless Jam Detect
150
Level
Key Fob Arming
153
Two-Way Voice
158
Session Configuration
Start Arming with
159
Faulted Points
Speak Active Faults
160
Wireless Transmission
161
Attenuation
Key Fob Button
616
Configuration
Key Fob Button
626
Configuration
Default
= Country-specific default. Select this programming item to hear the updated default value.
40
Description (Range)
Enter the hour that the control panel sends the test report (0 to 23).
Enter the minute that the control panel sends the test report
(0 to 59).
Select the day that the control panel sends the test report.
Program Item 116 must = 2 (Weekly).
0 = Sunday
4 = Thursday
1 = Monday
5 = Friday
2 = Tuesday
6 = Saturday
3 = Wednesday
Enter the day of the month that the control panel sends the test
report (1 to 28). Expert Programming Item Number 116 must = 3
(Monthly).
0 = User passcode can clear a confirmed alarm.
1 = Only installer passcode can clear a confirmed alarm.
0 = No arming beeps from control center and no outputs activation
during Entry Delay.
1 = No arming beeps from control center, but outputs activate during
Entry Delay.
2 = Control center sounds arming beeps, but outputs do not activate
during Exit Delay.
3 = Control center sounds arming beeps and outputs activate during
Entry Delay.
Configure the jam detect level of the wireless devices (0 to 15).
0 = Do not turn system on if there are faulted points
1 = Force arm faulted points if the number of faulted points is within
the range set in Expert Programming Item Number 125 (refer to
page 38)
2 = Force arm faulted points even if the number of faulted points
exceeds the range set in Expert Programming Item Number 125
0 = Allow two-way voice session to occur at any time
1 = Restrict two-way voice session to occur only during alarm
conditions
0 = All faulted points must be force armed before the system can be
turned on
1 = Exit Delay starts with faulted points
0 = Control center only speaks "Call for Service" when a fault occurs
1 = Control center speaks fault condition
0 = No signal attenuation
1 = 3 dB attenuation for EN 50131 Security Grade 1
2 = 6 dB attenuation for EN 50131 Security Grade 2
3 = 9 dB attenuation for EN 50131 Security Grade 3
4 = 12 dB attenuation for EN 50131 Security Grade 4
0 = Status request only
1 = Turn system on (occupied)
2 = Turn system on (custom protection)
3 = Turn output on or off
4 = Turn output on for 2 sec.
0 = Status request only
1 = Turn system on (occupied)
2 = Turn system on (custom protection)
3 = Turn output on or off
4 = Turn output on for 2 sec.