Table 2.8 Front Panel Of Tepri Module - Samsung OfficeServ 7400 General Description Manual

Hide thumbs Also See for OfficeServ 7400:
Table of Contents

Advertisement

The components on the front panel of the TEPRI module have the following functions:
Port / LED
T1/E1/PRI
SIO
RST
SYNC LED
LOS LED
AIS LED
L2 LED
IPC LED
CLK LED
TP1 LED
TP2 LED
© Samsung Business Communications

Table 2.8 Front Panel of TEPRI Module

Ports for connecting T1/E1/PRI cables
UART port (for testing)
Button for resetting TEPRI module
Clock Synchronization
- On: the circuit is receiving the clocking signal and is synchronised
- Off: the circuit is not receiving the clocking signal and is not synchronised
Signal loss generation
- On: Signal loss generated
- Off: No signal loss generated
T1/E1 remote alarm generation
- On: Remote alarm generated
- Off: No remote alarm generated
Layer 2 operation
- On: PRI Layer2 operation normal
- Off: PRI Layer2 operation abnormal
Interface with upper module
- On: Working with LP40
- Off: Not working with LP40
This LED indicates whether this module is a master or slave.
- On: The module is receiving the clock signal from the network and is the mas-
ter clock source for the system.
- Off: The module is not receiving the clock signal from the network OR it is not
the master clock source for the system.
T1 connection
- LED turns on when connected with T1
PRI connection
- LED turns on when connected with PRI
OfficeServ 7400 General Description
Function Description
2-13

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents