Stylus Pro 4000 Field Repair Guide

CR Encoder Sensor Position Adjustment

Purpose: The Carriage Encoder Sensor Position Adjustment is used to ensure that the Carriage Encoder Timing
Strip is centered in the Carriage Encoder Sensor across the entire length of the Printer Mechanism.
1. Sight down the Carriage Encoder Strip, and ensure that the Timing Strip is centered in the
Carriage Encoder Sensor, at the 2 positions marked below.
Check that the Strip is centered with the Carriage
Encoder in this position (left position)
Move the Left Side Encoder Strip Positioning
Lever until the Strip is centered at the left position.
CR Encoder Sensor Position Adjustment
Printer Component,
Software Item,
Check that the Strip is centered with the Carriage
Encoder in this position (right position)
Move the Right Side Encoder Strip Positioning
Lever until the Strip is centered at the right position.
LCD Display,
Printer Button
4/28/05
Page 149.