Hide thumbs Also See for 5 Inch Medium Speed Dome:

Advertisement

5 Inch Medium Speed Dome
User Manual
V2.0.0
2010-01

Advertisement

Table of Contents
loading

Summary of Contents for HIKVISION 5 Inch Medium Speed Dome

  • Page 1 5 Inch Medium Speed Dome User Manual V2.0.0 2010-01...
  • Page 2 5 Inch Medium Speed Dome User Manual Thank you for purchasing our product. If there is any question or request, please do not hesitate to contact dealer. This manual is applicable to 5 Inch Medium Speed Dome. This manual may contain several technically incorrect places or printing errors, and the content is subject to change without notice.
  • Page 3: Safety Instruction

    5 Inch Medium Speed Dome User Manual Safety Instruction These instructions are intended to ensure that user can use the product correctly to avoid danger or property loss. The precaution measure is divided into “Warnings” and “Cautions”: Warnings: Neglecting any of the warnings may cause serious injury or death.
  • Page 4: Table Of Contents

    5 Inch Medium Speed Dome User Manual Table of Contents Table of Contents................................. 3 Chapter 1 Brief Introduction............................4 1.1 Description..............................4 1.2 Outline ................................4 1.3 Functions ............................... 4 Chapter 2 Operation Instructions..........................7 2.1 Power-up Action ............................7 2.2 Basic Operations............................
  • Page 5: Chapter 1 Brief Introduction

    5 Inch Medium Speed Dome User Manual Chapter 1 Brief Introduction 1.1 Description Adopting the high-performance integral dome drive with auto iris, auto white balance and other capabilities, the medium speed dome is integrated with the built-in pan/tilt unit and the digital receiver. The dome provides Manchester code and wiring failure diagnosis;...
  • Page 6 5 Inch Medium Speed Dome User Manual Limit Stops The dome can be programmed to move within the limit stops (left/right, up/down) which are configurable by the control keyboard, DVR or client application software. Auto Scan The dome provides 5 scanning modes: pan scanning, tilt scanning, frame scanning, random scanning and panorama scanning. The scanning speed can be set by OSD menu from level 1 to 40, with the corresponding speed ranging from 1°/second to 40°/second.
  • Page 7 5 Inch Medium Speed Dome User Manual When the Wide Dynamic Range (WDR) function is on, the dome is able to balance the brightest and darkest sections of a scene to produce a picture that is better balanced in lighting and provides more details.
  • Page 8: Chapter 2 Operation Instructions

    5 Inch Medium Speed Dome User Manual Chapter 2 Operation Instructions 2.1 Power-up Action After the power is applied, the speed dome will perform self-test action that begins with lens actions and then pan and tilt movement. After completion of power-up self-test actions, the interface as shown in Figure 2.1 will be displayed on screen for 120 seconds.
  • Page 9: Presets With Special Functions

    5 Inch Medium Speed Dome User Manual numeric keys to call the programmed preset. E.g., the callup of preset 08 can be achieved by pressing PRESET button and then the numeral 08. Please refer to Section 3.2.4 for the configuration of presets.
  • Page 10: Chapter 3 Menu Operation

    5 Inch Medium Speed Dome User Manual Chapter 3 Menu Operation The menu varies depending on camera models. Note: Menu Tree SYS PARAMETER SETUP SYS PARAMETER SETUP DISPLAY SETUP Y - M - D 07 01 18 SOFT ADDR NUM <PAN ZERO SETUP>...
  • Page 11: Main Menus

    5 Inch Medium Speed Dome User Manual 3.1 MAIN MENUS In PELCO-P/D or other PTZ protocols, the main menu can be entered by calling preset 95 through DVR, Keyboard or Client Software, as shown in Figure 3.1.1. For instance, press the PTZ button on DVR front panel to enter the PTZ control mode, and then press the REC button followed by numeric 095 to access the main menu;...
  • Page 12: System Parameter Setup

    5 Inch Medium Speed Dome User Manual 3.2.1 SYSTEM PARAMETER SETUP The SYS PARAMETER SETUP menu is used for displaying the dome drive model, software version, available memory, DIP switch information, and other diagnostic information. Refer to Figure 3.2.2 and Figure 3.2.3.
  • Page 13: Camera Setup

    5 Inch Medium Speed Dome User Manual PAN ZERO SETUP (North Direction) Enter the PAN ZERO SETUP menu and then use the joystick of keyboard or the direction buttons on DVR front panel to define the amount of pan from zero degrees vertical, and finally press the Iris+ button to save settings and exit the current menu.
  • Page 14 5 Inch Medium Speed Dome User Manual Figure 3.2.8 FOCUS The camera provides three focus modes for selection: AF (auto), HAF (half-auto) and MF (manual). In auto focus mode, the camera will allow the lens to remain in focus when using pan, tilt and zoom (PTZ) functions.
  • Page 15: Ptz Parameter Setup

    5 Inch Medium Speed Dome User Manual When the Wide Dynamic Range (WDR) function is on, the dome is able to balance the brightest and darkest sections of a scene to produce a picture that is better balanced in lighting and provides more details.
  • Page 16 5 Inch Medium Speed Dome User Manual PTZ PARAMETER SETUP LIMITSTOP <LIMIT SETUP> <CLEAR LIMIT> ELEVATION SET BACK EXIT Figure 3.2.9 Figure 3.2.10 ATUO FLIP The dome will rotate 180 degrees when the camera tilts downward and goes just beyond the vertical position. When the dome rotates (flips), the camera starts moving upward as long as you continue to hold the joystick in the down position.
  • Page 17: Presets

    5 Inch Medium Speed Dome User Manual defined limit stops. LIMIT SETUP To set limit stops manually: 1. Enter the SETTING STOPS menu. 2. Follow the directions (SET LEFT LIMIT) displayed on the monitor and use the joystick or the direction buttons on DVR front panel to the desired location of left limit stop.
  • Page 18: Task Setup

    5 Inch Medium Speed Dome User Manual PATROL SETUP PATROL NUM <PATROL SETUP> <PREVIEW PATROL> <DELE PATROL> BACK EXIT Figure 3.2.12 Figure 3.2.13 PATROL SETUP The EDIT PATROL settings menu is shown in Figure 3.2.13. A patrol can be configured with 32 presets.
  • Page 19: Pattern Setup

    5 Inch Medium Speed Dome User Manual Set the task function to be ON or OFF. TASK ACTION This feature defines the activity the dome will perform at the specific time. The selectable actions include: presets1-8, patterns 1-4, patrols 1-4, pan scan, tilt scan, random scan, frame scan, panoramic scan, day mode, night mode, or none.
  • Page 20: Restore Defaults

    5 Inch Medium Speed Dome User Manual MEMORY indicates the memory available to configure the patterns. When it displays 0, no patterns can be memorized any more. Note: When configuring and calling the pattern, the auto flip will be valid; and the pan/tilt movement and the lens operation cannot be memorized simultaneously.
  • Page 21: Restore Camera

    5 Inch Medium Speed Dome User Manual 3.4 RESTORE CAMERA Use this function to reset all camera settings to factory default parameters 3.5 REBOOT DOME Use this function to reboot the system.
  • Page 22: Appendix 1 Lightning & Surge Protection

    5 Inch Medium Speed Dome User Manual Appendix 1 Lightning & Surge Protection This product adopts TVS plate lightning protection technology to avoid damage caused by pulse signal that is below 3000W, like instantaneous lighting, surging, etc. According to the actual situation outdoors, necessary protection measures must be taken to secure the electrical safety.
  • Page 23: Appendix 2 Rs485 Bus Connection

    5 Inch Medium Speed Dome User Manual   Appendix 2 RS485 Bus Connection 1. General Property of RS485 Bus According to RS485 industry bus standard, RS485 is a half-duplex communication bus which has 120Ω characteristic impendence, the maximum load ability is 32 payloads (including controller device and controlled device).
  • Page 24 5 Inch Medium Speed Dome User Manual Figure 3 4. Problems in the Practical Application Normally, users adopt star-shape connection method in construction, under this situation, the terminal resistors must be connected between two farthest devices (as Figure 4, 1# and 15#), but this connection method is not satisfy the requirement of the RS485 industry standard so that it will lead to some problems such as signal reflection, anti-jamming ability decline when the devices are faraway.
  • Page 25 5 Inch Medium Speed Dome User Manual Figure 5 1. FAQ of RS485 Bus...
  • Page 26: Appendix 3 24Vac Wire Gauge & Transmission Distance

    5 Inch Medium Speed Dome User Manual Appendix 3 24VAC Wire Gauge & Transmission Distance The following table has described the recommended max. distance adopted for the certain wire gauge when the 24VAC voltage loss rate is less than 10%. For the AC driven device, the maximum voltage loss rate allowable is 10%. For example, for a device with the rating power of 80VA which is installed at a distance of 35 feet (10m) away from the transformer, then the minimum wire gauge required is 0.8000mm.
  • Page 27: Appendix 4 Table Of Wire Gauge Standards

    5 Inch Medium Speed Dome User Manual Appendix 4 Table of Wire Gauge Standards Cross-sectional Area Bare Wire Gauge Americ an Wire Gage (British)St andard Wire Gauge Bare Wire (mm)

Table of Contents