HIKVISION 4-inch High Speed Dome User Manual
HIKVISION 4-inch High Speed Dome User Manual

HIKVISION 4-inch High Speed Dome User Manual

4-inch high speed dome
Hide thumbs Also See for 4-inch High Speed Dome:

Advertisement

Quick Links

4-inch High Speed Dome

User Manual

V1.0.0
Hikvision Digital Technology Co., Ltd.
http://www.hikvision.com

Advertisement

Table of Contents
loading

Summary of Contents for HIKVISION 4-inch High Speed Dome

  • Page 1: User Manual

    4-inch High Speed Dome User Manual V1.0.0 Hikvision Digital Technology Co., Ltd. http://www.hikvision.com...
  • Page 2 The updates will be added into the new version of this manual. We will readily improve or update the products or procedures described in the manual. © Hikvision Digital Technology Co., Ltd. All Rights Reserved.
  • Page 3: Regulatory Information

    (Cd), lead (Pb), or mercury (Hg). For proper recycling, return the battery to your supplier or to a designated collection point. For more information see: www.recyclethis.info. © Hikvision Digital Technology Co., Ltd. All Rights Reserved.
  • Page 4 (AC power).The socket outlet shall be installed near the equipment and shall be readily accessible. Installation and Maintenance:Do not connect/disconnect any cables to or perform installation/maintenance on this device during an electrical storm. © Hikvision Digital Technology Co., Ltd. All Rights Reserved.
  • Page 5 Lead Content: Please recycle this device in a responsible manner. Refer to local environmental regulations for proper recycling; do not dispose of device in unsorted municipal waste. © Hikvision Digital Technology Co., Ltd. All Rights Reserved.
  • Page 6: Safety Instruction

     Do not aim the camera at the sun or extra bright places. A blooming or smear may occur otherwise (which is not a malfunction however), and affecting the endurance of CCD at the same time. © Hikvision Digital Technology Co., Ltd. All Rights Reserved.
  • Page 7  Please use a soft and dry cloth when clean inside and outside surfaces of the dome cover, do not use alkaline detergents. © Hikvision Digital Technology Co., Ltd. All Rights Reserved.
  • Page 8: Table Of Contents

    3.6.5 Restoring Default Camera Settings ........................36 3.6.6 Rebooting the Dome ............................. 36 Appendix ................................37 Appendix 1 Lightning & Surge Protection ..........................37 Appendix 2 RS485 Bus Connection ............................38 © Hikvision Digital Technology Co., Ltd. All Rights Reserved.
  • Page 9 User Manual of 4-inch High Speed Dome Appendix 3 24VAC Wire Gauge & Transmission Distance ....................40 Appendix 4 Table of Wire Gauge Standards.......................... 41 © Hikvision Digital Technology Co., Ltd. All Rights Reserved.
  • Page 10: Chapter 1 Overview

    The dome can be programmed to move within the limit stops (left/right, up/down) which are configurable by the control keyboard, DVR or client application software. Auto Scan The dome provides 5 scanning modes: pan scanning, tilt scanning, frame scanning, random scanning © Hikvision Digital Technology Co., Ltd. All Rights Reserved.
  • Page 11 If the speed dome focuses on an object against strong backlight, the object will be too dark to be seen clearly. The BLC function can compensate light to the object in the front to make it clear, but © Hikvision Digital Technology Co., Ltd. All Rights Reserved.
  • Page 12 Cable is disconnected Cable is connected and data can be normally received, but the address setting is incorrect Cable is connected and data can be normally received, but the command setting is incorrect © Hikvision Digital Technology Co., Ltd. All Rights Reserved.
  • Page 13 Soft Baudrate The baudrate of dome can be configured by the menu without need of DIP switch settings. © Hikvision Digital Technology Co., Ltd. All Rights Reserved.
  • Page 14: Chapter 2 Getting Started

    You have to configure a protocol, an address and a baudrate for the dome the same as it in the other devices. 2.2 Basic Operations You can operate the speed dome using a control device. The control devices include the control © Hikvision Digital Technology Co., Ltd. All Rights Reserved.
  • Page 15: System-Defined Presets

    Patrol 5 Pattern 3 Patrol 6 Pattern 4 Patrol 7 Enable limit stops Patrol 8 Note: For Manchester code control protocol, the system-defined presets with special functions are shown as below: © Hikvision Digital Technology Co., Ltd. All Rights Reserved.
  • Page 16: On Screen Displays

    Direction: Displays panning and tilting direction, with the format of NEXXX TXXX. The XXX following NE indicates the degrees in north east direction, while the XXX following T indicates the degrees in tilt position. Time: Supports for time display. Preset Title: Identifies preset being called. © Hikvision Digital Technology Co., Ltd. All Rights Reserved.
  • Page 17: Chapter 3 Menu Operation

    PRESET PEED AE MODE WIDE LIMIT CLEAR LIMIT STOP CHROMA IRIS SETTINGS SUPPRESS <SETTING PASSWORD SHUTTER STOPS> SATURATION CLEAR STOPS GAIN ZONES CONTRAST EXPOSURE COMP LINE SYNC HR MODE GAIN LIMIT © Hikvision Digital Technology Co., Ltd. All Rights Reserved.
  • Page 18: Accessing And Operating The Menu

    On control panel of the live view interface of the DVR, you can click left and right direction buttons to turn page up or down. To change the value of a parameter: Steps: © Hikvision Digital Technology Co., Ltd. All Rights Reserved.
  • Page 19: Configuring System Information

     The temperature refers to the internal temperature of the speed dome. 3.2.2 Configuring System Parameters Purpose: You can check and also edit the system information of software address, baudrate, system time, etc. on the system information settings menu. © Hikvision Digital Technology Co., Ltd. All Rights Reserved.
  • Page 20 Steps: (1) Move the cursor to SYSTEM TIME using the direction buttons and click IRIS+ to enter. (2) Click the left/right direction buttons to position the cursor on the specific item © Hikvision Digital Technology Co., Ltd. All Rights Reserved.
  • Page 21 You can set the PROTOCOL STATUS SET as ON or OFF, and set the PROTOCOL SET as AUTO MATCH, PELCP-P, PELCO-D, Private-code, etc.  RS-485 checksum setting You can set the 485CHECK SET as ON or AUTO for improving the controlling effect. © Hikvision Digital Technology Co., Ltd. All Rights Reserved.
  • Page 22: Configuring Image Parameters

    You can set FOCUS LIMT as 1CM, 30CM, 1M, 3M or AUTO. Note: The focus limit value varies depending on the models of speed dome. Task 2: Configure the iris, gain and shutter speed.  Setting the AE mode Purpose: © Hikvision Digital Technology Co., Ltd. All Rights Reserved.
  • Page 23 (2) Slow shutter. You can set the SLOW SHUTTER value as 0, 1, 2, 3, 4 and 5. Task 3: Configure the zoom settings.  Setting the zoom limit Purpose: Zoom limit is a user-defined limitation of the zoom amount. Steps: © Hikvision Digital Technology Co., Ltd. All Rights Reserved.
  • Page 24 You can set the BLC/WDR value as ON or OFF to enable or disable the function. BLC LEVEL: You can manually adjust the backlight compensation level. Note: BLC level configuration varies depending on the model of the speed dome. Some models don’t support BLC LEVEL function. © Hikvision Digital Technology Co., Ltd. All Rights Reserved.
  • Page 25 In SELFDEF mode, you need to adjust the RED and BLUE values manually. ATW: In auto-tracking mode, white balance is continuously being adjusted in real-time according to the color temperature of the scene illumination. HAUTO: © Hikvision Digital Technology Co., Ltd. All Rights Reserved.
  • Page 26: Configuring Privacy Mask

    (1) Move the cursor to SET BLANK and click IRIS+ button to enter the editing mode as shown in the following figure. You can see a privacy mask on the live window. © Hikvision Digital Technology Co., Ltd. All Rights Reserved.
  • Page 27: Configuring Osd Settings

    5. Exit the MAIN MENUS interface. 6. On the live view screen, call preset 11 twice within 5 seconds to enter the SET TITLE menu, as shown in the following figure. © Hikvision Digital Technology Co., Ltd. All Rights Reserved.
  • Page 28 After exit the SET TITLE menu, you can call preset 12 twice within 5 seconds to delete the defined title and remove it from the screen.  Display the PTZ movements, alarm, system time, etc. © Hikvision Digital Technology Co., Ltd. All Rights Reserved.
  • Page 29: Configuring Ptz Control Parameters

    You can configure panning, tilting and zooming movements, and configure PTZ control functions including presets, patrols, patterns, etc. for the speed dome. 3.4.1 Configuring PTZ Parameters Enter PTZ configuration menu: MAIN MENUS > DOME SETTINGS > MOTION PARAMETER © Hikvision Digital Technology Co., Ltd. All Rights Reserved.
  • Page 30 It can also reduce the use of bandwidth in a digital network system. You can set IMAGE FREEZE on to enable this function.  PTZ speed Purpose: © Hikvision Digital Technology Co., Ltd. All Rights Reserved.
  • Page 31: Configuring Presets

    TASK 1: Set a preset. Steps: 1. Move the cursor to enter preset configuration submenu: MAIN MENUS > DOME SETTINGS > PRESETS PRESETS PRESET NUM [UNDEFINED] <EDIT LABEL> PRESET PTZ CLEAR PRESET BACK EXIT © Hikvision Digital Technology Co., Ltd. All Rights Reserved.
  • Page 32 LOWCASE[a b c d e f g h I j] ZOOM+DELETE CONTENTS FOCUS+CHANGE CONTENTS FOCUS-CHANGE MARKER ROCKER CHOOSE CONTENTS OPEN: SURE CLOSE: BACK Figure 3-15 Edit the Preset Label(2) 4. Set the preset position. © Hikvision Digital Technology Co., Ltd. All Rights Reserved.
  • Page 33: Configuring Patrols

    (3) Click IRIS+ again to confirm and exit edit mode of this column. Note: You can configure up to 8 patrols. PATROLS PATROL NUM EDIT PATROL PREVIEW CLEAR PATH BACK EXIT Figure 3-16 Patrol Configuration Menu 3. Edit the patrol. Steps: © Hikvision Digital Technology Co., Ltd. All Rights Reserved.
  • Page 34: Configuring Patterns

    A pattern is a memorized, repeatable series of panning, tilting, zooming and preset movements that can be recalled by a command or automatically performed by a configured function (alarm, park, time task, and power-up). © Hikvision Digital Technology Co., Ltd. All Rights Reserved.
  • Page 35 Notes:  REMAIN MEMORY indicates the remaining memory of the speed dome for configuring the patterns. When it reaches 0, no more patterns can be configured. You can also see the © Hikvision Digital Technology Co., Ltd. All Rights Reserved.
  • Page 36: Configuring Time Tasks

    (2) Click the up and down direction buttons to select the number of the task which is to be configured. (3) Click IRIS+ again to confirm and exit edit mode of this column. Note: You can configure up to 8 tasks. © Hikvision Digital Technology Co., Ltd. All Rights Reserved.
  • Page 37 (4) Click IRIS+ to confirm and exit. Note: The weekday can be set to be from Monday to Sunday or Whole Week. WEEK WHOLE WEEK START(H-M) END(H-M) DONE: OPEN QUIT: CLOSE Figure 3-21 Set the Task Time © Hikvision Digital Technology Co., Ltd. All Rights Reserved.
  • Page 38: Configuring Zones

    2. Choose the zone number: Move the cursor to ZONE NUM and click IRIS+ button to enter. Click the up and down buttons to choose the zone number to be configured. © Hikvision Digital Technology Co., Ltd. All Rights Reserved.
  • Page 39: Clearing Ptz Control Settings

    On DIAGNOSTICS submenu, you can also see the self-diagnostics information of the speed dome, including the occurrence of high temperature, the highest temperature, the occurrence of low temperature, the lowest temperature, the occurrences of video loss, low voltage, dome reboot, © Hikvision Digital Technology Co., Ltd. All Rights Reserved.
  • Page 40: Configuring And Handling Alarms

    (2) Click the up and down direction buttons to select the number of the alarm which is to be configured. (3) Click IRIS+ again to confirm and exit edit mode of this column. © Hikvision Digital Technology Co., Ltd. All Rights Reserved.
  • Page 41: Configuring Alarm Parameters

    You can set the ALARM REST DELAY from 0 to 300 seconds. 4. Resume the dome activity. You can set ALARM RESUME to ON to enable the speed dome to resume its previous activity after the triggered actions finished. Notes: © Hikvision Digital Technology Co., Ltd. All Rights Reserved.
  • Page 42: Configuring Auxiliary Alarm Output

    3.6 Others 3.6.1 Line Synchronization When you set LINE LOCK as OFF, the synchronization mode is internal synchronization. When you set LINE LOCK as ON, the synchronization mode is external synchronization. © Hikvision Digital Technology Co., Ltd. All Rights Reserved.
  • Page 43: Setting The Language Of The Menu

    4. Click the right direction button to move the cursor to INPUT PW AGAIN and input the password again. 5. Click IRIS+ to save the changes and exit. 6. Enter the START USING submenu and switch the status to ON and click IRIS+ to save. © Hikvision Digital Technology Co., Ltd. All Rights Reserved.
  • Page 44: Restoring Default Dome Settings

    Initial Position Zero angle Soft Baudrate Auto-focus Zoom limit Max. Optical Zoom Zoom speed High Slow Shutter IR cut filter Auto Backlight compensation AE mode Auto Exposure compensation White balance Auto © Hikvision Digital Technology Co., Ltd. All Rights Reserved.
  • Page 45: Restoring Default Camera Settings

    Note: Camera settings include the image parameters, lens settings and display settings. 3.6.6 Rebooting the Dome Enter MAIN MENUS > REBOOT DOME and click IRIS+ to reboot the speed dome remotely. © Hikvision Digital Technology Co., Ltd. All Rights Reserved.
  • Page 46: Appendix

    4Ω, the section al area of the grounding cable should be no less than 25mm2. For grounding instructions, please refer to the Installation Manual of Speed Dome. Lightning & Surge Protection Figure A- 1 © Hikvision Digital Technology Co., Ltd. All Rights Reserved.
  • Page 47: Appendix 2 Rs485 Bus Connection

    RS485 industry standard so that it will lead to some problems such as signal reflection, anti-jamming ability decline when the devices are © Hikvision Digital Technology Co., Ltd. All Rights Reserved.
  • Page 48 RS485 industry standard, in order to avoid those problems and improve the communication reliability. Show as figure 5. RS485 Distributor Figure A-5  FAQ of RS485 Bus © Hikvision Digital Technology Co., Ltd. All Rights Reserved.
  • Page 49 10%. For example, for a device with the rating power of 80VA which is installed at a distance of 35 feet (10m) away from the transformer, then the minimum wire gauge required is 0.8000mm. Wire Gauge Distance feet(m) Power (va) © Hikvision Digital Technology Co., Ltd. All Rights Reserved.
  • Page 50 User Manual of 4-inch High Speed Dome Appendix 4 Table of Wire Gauge Standards Cross-sectional Area Bare Wire Gauge Americ an Wire Gage (Brit ish)St andard Wire G auge Bare Wire (mm) © Hikvision Digital Technology Co., Ltd. All Rights Reserved.
  • Page 51 First Choice for Security Professionals...

Table of Contents