Honeywell Lynx Plus Series Installation And Setup Manual page 21

Honeywell lynx plus series security systems
Hide thumbs Also See for Lynx Plus Series:
Table of Contents

Advertisement

25 25 25 25
X10 HOUSE
X10
X10
X10
HOUSE CODE
HOUSE
HOUSE
CODE
CODE
CODE
26 26 26 26
CHIME BY BY BY BY ZONE
CHIME
ZONE
CHIME
CHIME
ZONE
ZONE
27 27 27 27
CLOCK DISPLAY
CLOCK
DISPLAY
CLOCK
CLOCK
DISPLAY
DISPLAY
29 29 29 29
DST MNTH
DST
MNTH STR
STR/END
END
DST
DST
MNTH
MNTH
STR
STR
END
END
30 30 30 30
DST WEEK
DST
WEEK STR
STR/END
END
DST
DST
WEEK
WEEK
STR
STR
END
END
31 31 31 31
SINGLE ALARM
SINGLE
ALARM SND
SND
SINGLE
SINGLE
ALARM
ALARM
SND
SND
32 32 32 32
FIRE SND
FIRE
FIRE
FIRE
SND
SND T T T T IMEOUT
SND
IMEOUT
IMEOUT
IMEOUT
Powerline Carrier Device (X10) House ID
Powerline Carrier Devices require a House ID. This field identifies this House ID to the
Control. The Powerline Carrier Devices are programmed in field ✻80.
SELECTIONS
0 = A
3 = D
6 = G
1 = B
4 = E
7 = H
2 = C
5 = F
8 = I
Chime by Zone
This option allows the installer to define the specific zones intended to chime when
faulted while the system is in Chime mode. If enabled, these zones are defined in zone
list 3 (see ✻81 Zone List Menu Mode).
SELECTIONS
0 = no (chimes on fault of any entry/exit or perimeter zone when Chime mode is activated)
1 = yes (chimes on fault of those zones assigned to Zone List 3 when Chime mode on)
Real Time Clock Display
Refer to the User's Manual for setting the clock time and date.
SELECTIONS
0 = do not display the time
1 = display the time
Daylight Savings Time Start/End Month
Enter # + 10 for 10, # + 11 for 11, and # + 12 for 12.
SELECTIONS
0 = do not display the time
1 = display the time
Daylight Savings Time Start/End Month
Enter the appropriate start and end weekend of the month.
SELECTIONS
0 = disable
1 = first weekend of month
2 = second weekend
3 = third weekend
Single Alarm sounding Per Zone
This field applies only to burglary zones (zone response types 1-5, 10). It applies only to
the bell and does not affect keypad sounds.
UL installations: must be 0 (no limit)
Lynx Plus SELECTIONS
0 = no limit on alarm sounding per zone
1 = limit alarm sounding to once per arming period for a given zone
LynxSIA Plus SELECTIONS
0 = alarm sounding per zone will be the same as Swinger Shutdown set in field ✻92
1 = limit alarm sounding to once per arming period for a given zone
Sounder Timeout
This Control complies with NFPA requirements for temporal pulse sounding of fire and
carbon monoxide (CO) notification appliances. Temporal pulse sounding for a fire alarm
consists of the following:
3 pulses – pause – 3 pulses – pause – 3 pulses. . .
Temporal pulse sounding for a CO alarm consists of the following:
4 pulses – pause – 4 pulses – pause – 4 pulses –pause. . .
SELECTIONS
0 = yes, sounder timeout after time programmed in field ✻33
1 = no sounder timeout; continue sounding until manually turned off
Lynx Plus Series Installation and Setup Guide
Data Field Descriptions
9 = J
# + 10 = K
# + 11 = L
4 = fourth weekend
5 = last weekend
6 = next to last
7 = 3rd from last
(per armed period)
- 21 -
# + 12 = M
# + 15 = P
# + 13 = N
# + 14 = O