Vibrator; Introduction; Measure Method - Asus M530w Service Manual

Level 3 & level 4 service manual
Hide thumbs Also See for M530w:
Table of Contents

Advertisement

9. VIBRATOR

9.1 Introduction

The Handset controls the vibrator by the PMIC- DA9030(U20).

9.2 Measure method

1. Set up the power supply voltage and current at 4V and 1A.
Connect to the battery connector positive and negative of the
handset.
2. Press the POWER ON Key to power on the handset.
3. After entering the MMI Test Mode, select the "set
Vibrator" test item. Press "on",the vibrator should vibrate.
0.1UF/10V
umt3_rohm ==>
sot_416
VBAT
2
R216
1
0Ohm
1
2
C213
D207
1SS400
2
1
VIB_D_AN
2
1
R218
0Ohm
2
R220
5.1Ohm
_ D
1
S
O
_ M
I B
V
3
Q3
D
SI1012R
2
G
S
1
1
R222
100KOhm
2
GND
GND
Vibrator circuit
24
TSD ■ Lv3Lv4 Repair Manual
VIB_IN
2
U13
2
$VIBRATOR_2P
1
1
VIB_OUT
VIBRATOR_EN [10]
ASUS Proprietary

Advertisement