Advertisement

OPERATING INSTRUCTIONS UPS
PROTECT HOME.
PROTECT HOME.

Advertisement

Table of Contents
loading

Summary of Contents for AEG Protect Home

  • Page 1 OPERATING INSTRUCTIONS UPS PROTECT HOME. PROTECT HOME.
  • Page 2 Thank you for purchasing the AEG UPS PROTECT HOME. from AEG Power Solutions. Safety information and operating instructions are included in this manual. To ensure correct use of the UPS, please read this manual thoroughly before operating it. Save this manual properly.
  • Page 3: Warranty And Liability

    Please read these instructions carefully prior to commissioning! These operating instructions are a composite part of PROTECT HOME. The operator of this unit is obliged to communicate these instructions to all personnel transporting or starting PROTECT HOME. or performing maintenance or any other work on the unit.
  • Page 4 AEG and its representatives without prior notification in the event of maintenance and repair work being carried out with anything other than original AEG spare parts or spare parts purchased by AEG. Handling PROTECT HOME. is designed and constructed so that all necessary steps for start-up and operation can be performed without any internal manipulation of the unit.
  • Page 5 Certification...
  • Page 6: Important Safety Instructions

    PROTECT HOME. UPS and observe the safety instructions! Only use the unit if it is in a technically perfect condition and always in accordance with its intended purpose, while being aware of safety and danger aspects, and in accordance with the operating instructions! Immediately eliminate any faults which could be detrimental to safety.
  • Page 7 For health and safety reasons, the unit must be earthed correctly! PROTECT HOME. may only be operated with or connected to a 230 VAC mains with protective grounding using a mains connection cable with PE conductor (included in the delivery) that has been tested in accordance with German standards (VDE).
  • Page 8  Ensure that no fluids or foreign bodies can penetrate the UPS!  Do not block the side air vents of the unit! Keep children away from the unit and ensure that objects are never inserted through the vents!  Do not connect household appliances such as hairdryers to the UPS! ...
  • Page 9 Therefore, take the following safety precautions when working with batteries:  Take off watches, rings and other metallic objects!  Always use tools with insulated handles! For personal safety reasons, never switch on the main switch when the mains connector of PROTECT HOME. is disconnected!
  • Page 10: System Description

    In the event of a mains failure PROTECT HOME. supplies voltage until the battery is discharged, allowing you to shut down your IT system properly and switch it off. The standby time mainly depends on the connected loads.
  • Page 11: Ups Overview

    UPS overview Connections, Operation / Display Elements:  Top view Power switch of the UPS (mains switch)  Green LED: Normal / power mode  Yellow LED: Battery mode  Red LED: Warning / failure  Surge protected only receptacles (without UPS protection) ...
  • Page 12: Specifications

    Specifications MODEL PROTECT HOME. Type power 600 VA / 300 W UPS-input Input voltage ( 1ph ~ / N / PE ) 230 Vac Input voltage range + 6% / - 10% without battery mode Frequency 50 / 60 Hz ± 5 Hz...
  • Page 13 (1 x with surge protection / 3 x additional UPS outlets) Guidelines The PROTECT HOME. complies with the product norm EN 50091. The CE symbol on the unit certifies the compliance to the EG guidelines for 73/23 EEC low voltage and for 89/336 EEC electromagnetic compatibility (EMC), when following the installation instructions in the manual.
  • Page 14: Setup And Operation

    Do not use the UPS in environments with high temperatures or humidity. Charging The PROTECT HOME is shipped from the factory with its internal battery fully charged, however, some power may be lost during shipping and the battery should be recharged prior to use.
  • Page 15: Computer Connection

    > 8 hours Computer connection Connect one computer-related device into one of the battery supplied receptacles on the top of UPS. PROTECT HOME. provides four receptacles, three battery supplied receptacles and one surge protected only receptacles (marked “Battery Backup”). Connection of peripheral devices An additional outlet (marked “Surge Only”) with protection...
  • Page 16: Modem / Phoneline Connection

    Connect the incoming antenna line with the F connectors (optional via adapter plugs IEC) in the “IN” socket on the rear of your PROTECT HOME. Use the second antenna line and connect the “Out” socket with the Receiver, Decoder, TV, etc.
  • Page 17: Dc Start Function

    The connection vie the USB connector will be auto detected. Turn On/Off Turn On/Off To turn on the PROTECT HOME., press the on/off switch. To turn on the PROTECT HOME., press the on/off switch. To turn off the PROTECT HOME., press the on/off switch To turn off the PROTECT HOME., press the on/off switch...
  • Page 18: Battery Removal

    5.12 Battery removal Battery replacement should be performed by qualified service personnel. Keep unauthorized persons away from the batteries! Disconnect all power sources before battery replacement. Follow Fig. 1 below to remove the screws located on the bottom of the UPS to open the battery cover. Fig.
  • Page 19: Shutdown- And Ups Management Software

    5.13 Shutdown- and UPS management software The "CompuWatch" software specially developed for these purposes by AEG continuously checks the mains supply and the UPS status. In conjunction with the "intelligent" UPS, this ensures that the availability of IT components and data security are guranteed.
  • Page 20: Troubleshooting

    Trouble shooting Error Cause Remedy Yellow LED is UPS not connected Connect the UPS lighting, but audible properly to the mains. according to the alarm is heard installation guide. intermittently. UPS is functioning UPS overload. Verify that the load but audible alarm is matches the UPS heard periodically.
  • Page 21 Guarantee certificate Type: …….…………………............Serial-no.: ……………………..……………....... Date of purchase: …………….....……………………..Trading stamp / Signature Specifications are subject to change without notice. AEG Power Solutions GmbH Emil-Siepmann-Straße 32 59581 Warstein-Belecke Germany Operating Instructions UPS BAL 8000017714_01 EN...

Table of Contents