5.7 Deleting the last alarm
It is good practice to cancel the alarms stored:
After reading the alarm codes, to check whether the alarm re-occurs during the diagnostic cycle.
After repairing the appliance, to check whether it re-occurs during testing.
1. Enter the diagnostic mode (para. 7.1).
2. Turn the selector clockwise until the eleventh LED lights up.
3. Touch the START/PAUSE and the nearest option sensor simultaneously (as shown
in the figure).
4. Keep your fingers over the sensors until the LCD display shows "E00" (at least
5 seconds).
N.B. With this operation all the alarms stored are deleted.