Reading The Alarms; Tc3-Tc2 Styling; Rapid Reading Of Alarms - Electrolux TC3 Service Manual

Washing machines with electronic control system
Hide thumbs Also See for TC3:
Table of Contents

Advertisement

5.5 Reading the alarms

The last three alarms stored in the FLASH memory of the PCB can be displayed:
5.5.1 TC3 – TC2 styling
Enter the diagnostic mode (para. 7.1).
Irrespective of the type of PCB and configuration, turn the programme selector
knob clockwise to the eleventh position, the last alarm will be displayed.
To display previous alarms, touch the sensor closest to the START/PAUSE
sensor in sequence (as shown in the figure).
To return to the last alarm, touch the START/PAUSE sensor.

5.6 Rapid reading of alarms

It is possible to display the last alarm even if the selector is not in the eleventh diagnostics position or if the
appliance is in normal operating mode (for example when performing a wash programme):
→ Touch the START/PAUSE sensor and the nearest option sensor simultaneously (as if you were entering
DIAGNOSTIC mode) and hold for at least 2 seconds: the LCD display shows the last alarm.
→ The alarm will continue to be displayed until a sensor is touched.
→ The alarm reading system is as described in para. 8.2.
→ While the alarm is displayed, the appliance continues to carry out the cycle, or if it is are in the programme
selection phase, it retains the options selected previously in memory.
Technical Support – ADL
TC3
28/43
TC2