5 DIAGNOSTICS SYSTEM
5.1
Accessing diagnostics
The operations listed below must be carried out within 7 seconds.
Do not start the procedure with your fingers over the combination sensors
1. Switch on the appliance using the ON/OFF button. The first LED lights up.
2. Touch the START/PAUSE and the nearest option sensor simultaneously (as shown in the figure).
3. Hold your fingers over the sensors until the LEDs and symbols begin to flash in sequence (approximately
3 seconds).
In the first position, the operation of the sensors, the LEDs and the groups of symbols shown on the LCD
display is checked;
For the TC3 and TC2 styling:
When the programme selector is turned in a clockwise direction, operation of the various components is
diagnosed and the alarms are read (see diagnostic test on the next page).
5.2 Quitting the diagnostics system
To exit the diagnostic cycle, switch the appliance off, then back on and then off again.