9.4 Selector positions for diagnostics on appliances with styling TC6

Selector position
1
2
3
4
5
6
7
8
SOI/ADL
Components activated
All LEDs and digits light up in sequence
When a button is pressed, the
corresponding LED lights and the buzzer
sounds
Condensation canister level sensor
Canister fill pump
Motor triac and relay.
Canister fill pump always powered
Triac motor in stepping operation.
Higher-power heating element.
Motor triac for ventilation.
Full-power heater
Clockwise drum rotation motor
Full-power fan motor
Floating switch
Canister fill pump with switch closed
Reading/cancellation of the last alarm
code
Turn the knob till position, paying attention
not to stop in the other positions
31/57
Operating
Function checked
conditions
Operation of the user
Always active
Door closed.
Operation of the floating
Sump full (about 0,7
switch and canister fill
litres)
Door closed
Drum anti-clockwise
Max time 10 min.
Pump 30sec.
Control of clockwise
drum rotation (low
Door closed. Max.
time 10 min.
inspection of drum shell
Control of clockwise
drum rotation (low
Door closed. Max.
time 10 min.
inspection of drum shell
Door closed
Heater unit (full power).
Max time 10 min.
Door closed. Max.
Operation of floating
time 30 sec.
switch (sump empty)
599 38 46-21
interface
pump
rotation control
speed for visual
assembly).
speed for visual
assembly