EC is the "Check for a number" command
F1 is the "Send all characters" command
0D is the hex value for a CR
If this bar code is read,
there is one, will be used on the data. If there is no other format, the
format fails and the raw data is output as AB1234.
If this bar code is read:
1234AB
<CR>
Check for non-numeric character
ED Check to make sure there is a non-numeric ASCII character at the
current cursor position. The format is aborted if the character is
numeric.
ED Example: Only output the data if the bar code begins with a
letter
If you want only data from bar codes that begin with a letter, you can
use ED to check for the letter.
Command string: EDF10D
ED is the "Check for a non-numeric character" command
F1 is the "Send all characters" command
0D is the hex value for a CR
If this bar code is read,
there is one, will be used on this data. If there is no other format, the
format fails and the raw data is output as 1234AB.
If this bar code is read:
AB1234
<CR>
Insert a delay
EF Inserts a delay of up to 49,995 milliseconds (in multiples of 5), starting
from the current cursor position. Syntax = EFnnnn where nnnn stands
for the delay in 5ms increments, up to 9999. This command can only
be used with keyboard emulations.
the next data format, if
the data is output as:
the next data format, if
the data is output as: