7.9

Added drive reported as defective

RAID controller is not configured for this drive
The drive was probably installed when the system was switched off.
Ê Reconfigure the RAID controller for the drive using the corresponding utility.
Information is provided in the documentation for the RAID controller.
or
Ê Remove and reinstall the drive while the system is switched ON.
If the hard disk drive continues to be shown as defective, then replace it (see
"Hot-plug disk drives" on page
7.10

Error message on screen

The meaning of the error message is explained in the documentation for the
relevant components and programs on the ServerView Suite DVD 2.
7.11
Expansion cards or onboard devices not
recognized
When an expansion card is added, other expansion cards or onboard devices
might not be recognized.
Ê Reinstall the drivers for the expansion cards or onboard devices that are not
recognized.
7.12

Temperature warning

A temperature warning is output to the hardware event log and OS event log, or
ServerView issues a notification of a temperature warning such as by a popup
message
RX300 S6
Added drive reported as defective
100).