Summary of Contents for Sharp RZ-X650

  • Page 1 MSR USER GUIDE POS TERMINAL RZ-X650 MODEL This document has been published to be used SHARP CORPORATION for after sales service only. The contents are subject to change without notice.
  • Page 2: Table Of Contents

    Contents 1. MSR operations type options………………………………………….… 1 2. Installing the Keyboard Interface re-director…………………………. 1 3. Enabling the MSR keyboard mode……………………………………… 3 4. Disabling the MSR keyboard mode (for Setter configuration)…….. 4 5. MSR Keyboard settings…………………………………………………… 5 6. MSR keyboard operation verification…………………………………… 6 7.
  • Page 3: Msr Operations Type Options

    RZ-X650 MSR User Guide 1. MSR operations type options The RZ-X650 Magnetic Card Reader (MSR) supports several operation modes to provide a range of connection methods for software applications. • Serial device (default) • OPOS driver (default) • Keyboard interface device 2.
  • Page 4 RZ-X650 MSR User Guide 3. Select INSTALL 4. Touch FINISH SHARP...
  • Page 5: Enabling The Msr Keyboard Mode

    RZ-X650 MSR User Guide 3. Enabling the MSR keyboard mode If the MSR_KBD utility has been removed and is required follow these steps: 1. Touch the windows [Start] button 2. Select Programs 3. Select the MSR-KBD folder 4. Select MSR_KBD program 5.
  • Page 6 RZ-X650 MSR User Guide 4. Disabling the MSR keyboard mode (for OPOS / Serial use) To temporarily disable the keyboard interface mode (example: to make configuration changes) follow these steps: 1. Touch the MSR_KBD icon and hold for approximately 2 seconds 2.
  • Page 7: Msr Keyboard Settings

    RZ-X650 MSR User Guide 4. Close the settings window 5. Reboot the unit 6. The MSR-KBD icon should not be visible now 5. MSR Keyboard settings The MSR_KBD program contains settings for the direct interface to the MSR device. 1. Touch the MSR-KBD icon 2.
  • Page 8: Msr Keyboard Operation Verification

    RZ-X650 MSR User Guide 4. Available settings include: a. Com Port Default = COM5 b. Baud Rate Default = 19200 c. Data Bit Fixed at 8 d. Parity Bit Fixed at N e. Stop Bit Fixed at 1 Hand Shaking Default = None g.
  • Page 9 RZ-X650 MSR User Guide SHARP...
  • Page 10: Msr Setter Utility (Swipe Format Configuration)

    RZ-X650 MSR User Guide 7. MSR Setter Utility (Swipe format configuration) The MSR Setter is used to select and configure what data is received by the POS terminal. A. Starting MSR Setter utility Touch the windows [Start] button Select Programs...
  • Page 11 RZ-X650 MSR User Guide B. Setter (Configuration) utility overview Module Setting: Fixed as ISO 1&2&3 Sound: Control tone of beep when swiping cards Track Setting: Control tracks Read, Start Code (prefix), End Code (suffix), Enter character at track end Error Setting: Displays status of error...
  • Page 12 RZ-X650 MSR User Guide C. Track Setting By default the standard ISO codes (shown below) will be used. To change the data format or characters used for application specific purposes use the Track Setting options. Module Setting: Fixed as ISO 1&2&3...
  • Page 13 RZ-X650 MSR User Guide D. Sound Setting The beep sound volume can be set to Mute (none), Low, Medium or High by selecting the appropriate radio button. E. Error Setting There will reports an error status as “~~~”mark when there cannot read Magnetic Card data.
  • Page 14 RZ-X650 MSR User Guide F. COM settings Touch [Set Up] button to view or adjust the COM Port settings for the MSR Port: Select the Port for connection to the MSR device Baud rate: Select the baud rate for communicating with the MSR device NOTE: Default Port is COM5 and Baud rate is 19200.
  • Page 15 RZ-X650 MSR User Guide If State is DisCon check the COM settings using [Set Up] and confirm that they are correct. If State remains at DisCon check that the wire from the MSR to the main PWB is properly connected.
  • Page 16 RZ-X650 MSR User Guide Touch [Data Write] to send new settings NOTE: The COM State must be Connect to Write settings. If the State is DisCon you will receive an error message. See COM settings for detailed information. H. Data Read...
  • Page 17 RZ-X650 MSR User Guide The current settings will be shown in the Track Setting area Status of updated MSR setting Test Mode SHARP...
  • Page 18 RZ-X650 MSR User Guide Test Mode is used to verify that the data received matches the settings in Track Setting Touch the [Test Mode] button Swipe a test card through the MSR Verify that the data received matches the desired settings...
  • Page 19 RZ-X650 MSR User Guide Save After manually creating custom MSR settings you can save it to an external file for easy installation in future POS terminals The following data will be saved in this file a) Sound b) Track Setting...
  • Page 20 RZ-X650 MSR User Guide Touch [Save] to save the settings file K. Open SHARP...
  • Page 21 RZ-X650 MSR User Guide 1. Open requested MSR setting file. 2.Verify detail of file SHARP...
  • Page 22 RZ-X650 MSR User Guide 3. Check the file of MSR setting. - Should be “DisConnect” state. * If COM state is not available to save (Discon status). You will have to change state to Connect. 1) click Set Up .
  • Page 23 COPYRIGHT ○ 2011 BY SHARP CORPORATION All rights reserved. Printed in Korea. No part of this publication may be reproduced, Stored in a retrieval system, or transmitted. In any form or by any means, Electronic, mechanical, photocopying, recording, or otherwise,...