Cabling Recommendations and Cautions

General Cautions and Notes for All Cable Installations

20
Cable preparation should be completed prior to the installation. Each dome requires 24V
AC at 1 A or 12V DC at 1.5 A. The power supply should be located as close to the dome as
possible for service and electrical isolation purposes. In situations where the power supply
has to be installed remotely, see
the recommended power supplies for use with the indoor ACUIX ES.
If required, refer to other hardware installation guides to determine cabling requirements
based on the individual configuration. See
Faulty cable or wiring can cause all domes to fail or malfunction.
If several domes are powered from a single power source (multiple tap) and noise
is experienced on the TP video output, then an isolated power supply should be
used to correct the problem.
Never run the cables close to potential sources of electromagnetic interference
such as motors, dimmers, and high-speed data trunk cables.
For CE compliance, the power supply must be connected to a CE-approved 240V
UPS (uninterruptible power supply). See
which must be used to meet FCC and UL requirements.
Note
For all cables:
The quality and specification of any cable used has a direct effect on the
quality of the video signal at the control equipment end of the system.
Compromising the cable quality and specification can lead to poor video
quality and system performance.
When other cables cannot be avoided, run cables perpendicular to each
other, not alongside, and keep this distance as short as possible.
Table 1-5
for wire gauges and distances. See
Finding More Information
Table 1-6
for a list of the power supplies
Table 1-6
for
on page 13.