FIELD
TITLE and DATA ENTRIES
Suppress Transmitter
1*49
Supervision Sound
0 = disable
1 = enable
Send Cancel If Alarm + Off
1*52
(partition-specific)
0 = disable
1 = enable

Disable Download Callback

1*53
0 = callback required
1 = no callback required
Enable 5800 RF Button Global
1*57
Arm
0 = disable
1 = enable
Enable 5800 RF Button Force
1*58
Arm
0 = disable
1 = enable

Zone 5 Audio Alarm Verification

1*60
0 = disable
1 = enable

Event Log Types

1*70
0 = disable
1 = enable
12/24 Hour Type Stamp Format
1*71
0 = 12-hour
1 = 24-hour

Relay Timeout XXX Minutes

1*74
Enter 000-127 times 2 minutes (000-254).

Relay Timeout YYY Seconds

1*75
Enter 000-127 seconds.
Access Control Relay (partition-
1*76
specific)
01-08 = relay number
00 = relay not used.

Number of Partitions

2*00
Enter 1-2.
Daylight Saving Time Start/End
2*01
Month
0 = disable
1 = enable
EXPLANATION
If enabled, no trouble soundings occur on the keypad for transmitter
check-in failures.
Must be 0 for UL.
If enabled, Cancel reports are sent when the system is disarmed after an
alarm, regardless of how much time has gone by.
If disabled, Cancel reports are sent within Bell Timeout period only.
NOTE: This option must be enabled so Cancel reports are always sent.
Select whether a callback from the control panel is required for
downloading.
Must be 0 for UL installations.
If enabled, the system arms/disarms in accordance with the button's
user's global arming settings.
If enabled, allows the RF button user to force a bypass of all faulted zones
when arming the system.
NOTE: When attempting to arm the system, the keypad beeps once after
the button is pressed if any faulted zones are present. The user should
then press the button again within 4 seconds to force-bypass those zones
and arm the system.
If enabled, zone 5 is used for 2-way audio (AAV).
Must be 0 for UL installations.
NOTE: Zone 5 cannot be used as protection zone.
This field has five entries as follows: Alarm, Check, Bypass, Open/Close,
and System. If enabled, the system logs those events into the event log.
Select the type of time stamping for the event log.
This is used for Relay Programming in the #93 Menu Mode Programming
relay command "56."
This is used for Relay Programming in the #93 Menu Mode Programming
command "57."
If enabled, the assigned relay closes for 2 seconds when the user enters
his code and presses 0.
Must be 00 for UL installations.
Enter the number of partitions used in the system.
Enter the months (00-12) in which daylight saving time starts and ends.
Enter 00, 00 if daylight saving time does not apply to the user's region.
Standard setting for U.S. is 04,10.
Section 5 – Data Field Descriptions
5-11