Installing the indoor unit

Choose installation location
1. The height of installation should be 2
to 3 meters from the floor.
2. The air inlet and outlet of the indoor unit
should not be covered or blocked in any
way so that the conditioned air can reach
all parts of the room.
3. Select a location which enables easy
connection with the outdoor unit. Take
into consideration the maximum allowed
length and height of piping. This data is
provided in the installation data at the
end of this manual.
4. Select a location where accumulated
condensation can be drained
conveniently.
5. Avoid locations near a heat source, high
humidity or an inflammable gas.
6. Select a location strong enough to
withstand the full weight and vibration of
the unit.
7. The location should conform to the
installation dimension diagram.
8. Be sure to leave enough space to allow
access for routine maintenance.
9. Install at least 1 meter away from other
electric appliances such as television,
audio device, etc.
10.Choose a location where it is easy to
remove and clean the filter.
11.Do not install the unit in the immediate
vicinity of a laundry, bath, shower or
swimming pool.
12.The power plug must be accessible after
the appliance is correctly positioned.
Install the rear panel
1. Always mount the rear panel horizontally.
2. Fix the rear panel on the selected location
with the screws supplied with the unit.
3. Be sure the rear panel is firmly fixed.
16
The mounting must be able to withstand
a weight of at least 60 kilograms.
The weight should be evenly shared by
each screw.
Electrical wiring
To connect the connecting cable, refer to
table 1 and table 2 below to identify the
required electrical wiring for your air-
conditioner and follow these instructions.
1. Lift the indoor unit front cover.
2. Remove the lid for terminal block located
on the right of the unit.
3. Route the connecting cable from the back
of the indoor unit and pull it toward the
front through the wiring hole for
connection.
4. Connect the wires strictly based on the
correspondence between the wire colors
and the terminal block codes as
described in table 2.
5. Hold the connecting cable with the wire
clamp. Then, re-assemble the lid of
terminal block back to the front cover. For
GE AIR Z09 and GE AIR Z12, the lid of
terminal block acts as the wire clamp and
cable is fixed when the lid is re-
assembled to the front cover.
6. Re-assemble the front cover.