Cooling System (CT8775C Only)
CAUTION
Equipment Damage Hazard.
Can cause permanent damage to compressor or other equipment.
Do not operate cooling when outside temperature is below 50°F (10°C).
Allow compressor to remain off for five minutes before restarting.
See equipment manufacturer instructions.
Slide the system switch to Cool and the Fan switch to Auto.
Turn the dial counterclockwise to lower the temperature setting several degrees below the room temperature.
NOTE:
If a call for cooling is made before the compressor has been off for five minutes, or if a power interruption
occurs while the compressor is running, the thermostat will go into a five-minute delay to protect the com-
pressor. The snowflake
After five minutes, the thermostat will display a solid snowflake
The cooling system should turn on.
Turn the dial clockwise to raise the temperature setting above the room temperature.
The snowflake
will disappear from the display to indicate the thermostat has ended the call for cooling. The
cooling system should turn off.
Fan (CT8775C Only)
Slide the system switch to Off and the fan switch to On. The fan should run continuously.
Slide the Fan switch to Auto. The fan should turn off.
69-1676—1
will flash during this delay.
14
to indicate the thermostat has called for cooling.