Transmitter Holding Registers; Device Id Mapping Mode; Register Mapping Mode - Honeywell ISM BAND XYR 5000 LINE User Manual

Base radio 900 mhz ism band
Table of Contents

Advertisement

total from the subtraction and subtract the next largest number possible and so on until
the result is zero. Each value that was used in the subtraction indicates that the
Transmitter is online.
For example: The On/Offline Status holding register contains the value 15. In this case
the largest value we can subtract is 8, which leaves a result of 7. Now we can subtract 4
from 7 and get 3. Now subtract 2 from 3 and we get 1. Finally we subtract 1 from 1 and
get 0, so we are done. Which Transmitters are online? We subtracted 8,4,2 and 1, and
these numbers correspond to Transmitters' with RF IDs 1,2,3 and 4.
Note An alternate method to determining which Transmitter(s) are online is to look at the
Base Radio Holding Register as a binary number with the rightmost bit representing
Transmitter 1 and the leftmost bit representing Transmitter 16. For example, the binary
representation for Transmitters 1-4 online is as follows:
0000000000001111
In another example, say the On/Offline Status holding register contains the value 6. We
can subtract 4 to get 2. Then we can subtract 2 to get 0. Thus Transmitter 2 and 3 are
online, but Transmitters 1 and 4 are offline.
6.5

Transmitter Holding Registers

The following are the Transmitter holding registers when used in the Device ID Mapping
Mode (First Table) and the Register Mapping Mode (Second Table).

6.5.1 Device ID Mapping Mode

Transmitter Holding
Registers
(DEVMODE Only)
Register Address
00001
00002
00003
00004
00005
00006
00007
00008
00009
00010

6.5.2 Register Mapping Mode

Transmitter Holding
Registers
(REGMODE Only)
Register Address
00001 + (RF ID * 10)
00002 + (RF ID * 10)
00003 + (RF ID * 10)
00004 + (RF ID * 10)
31
Device ID =
Base Radio Modbus ID + RF ID
Description
Device Type
Device Type
Device Status
Device Status
Primary Sensor Value
Primary Sensor Value
Secondary Sensor Value
Secondary Sensor Value
Tertiary Sensor Value
Tertiary Sensor Value
Device ID =
Base Radio Modbus ID
Description
Device Type
Device Type
Device Status
Device Status
Register Type
32-Bit IEEE
Floating Point
32-Bit IEEE
Floating Point
32-Bit IEEE
Floating Point
32-Bit IEEE
Floating Point
32-Bit IEEE
Floating Point
Register Type
32-Bit IEEE
Floating Point
32-Bit IEEE
Floating Point