Download Print this page

Honeywell GSS Series Specifications page 6

Global safety switch

Advertisement

GSC EN 50047
Safety Metal
Standard
Technical Data
Mechanical
up to 15 million
life
operations
Degree of
IP 66
protection
NEMA/UL
type 1, 4, 12, 13
Temperature
Operating:
range
-25 °C to +85 °C /
-13 °F to +185 °F
Storage:
-40 °C to +85 °C /
-40 °F to +185 °F
Approvals*
IEC 60947-5-1
EN 60947-5-1
ac15 A300
dc13 Q300
BG, UL & CSA
Vibration
10 g conforming to
IEC 68-2-6
Shock
50 g conforming to
IEC 68-2-27
Terminal marking to EN 50013
*See Standards (page 179)
Dimensions in mm / in
22 /
0.87
20 /
24,75 /
0.97
0.78
3 /
0.12
2,15 /
R
0.08
30,5 /
14,5 /
1.20
0.57
30 /
1.18
conduit
thread
ø 23 /
ø 0.9
Note: Incorporates safety screws
Ordering:
GSC
Example: GSC C 01 B
202
Snap-Action Contacts
1 NORMALLY CLOSED/
1 NORMALLY OPEN
21-22
13-14
21-22
13-14
OP 18 mm
55 /
2.16
3,5 /
0.138
* Point from which the positive opening is assured
19,8 /
Conduit
** Positive opening occurs at operating position. But to meet IEC/EN 60947-5-3
0.78
Thread
which requires a dielectric gap of 2,5 kV, positive opening is assured at*.
A
= 1/2" NPT
= 20 mm
C
Low Energy Contacts
Note: See page 197
X
• Industrial Safety Products •
13
14
Zb
22
21
Circuit closed
*Positive opening to IEC/EN 60947-5-1-3
-4,4
15 mm
43,3
(F.P.)
(O.P.)
26˚
(R.P.)
14,5˚
*
FP
OP
OT
DT = 9,8 mm
(D.T.)
11,5˚
(
*
)
54˚
(O.T.)
61˚ to 75˚
RP = 5,2 mm
FP
21 mm
DT =
0,9 mm
18,9 mm
RP
16 mm
*
15 mm
OT
(max.)
10,5
5,3 mm
13,9
21-22
13-14
*
FP
OT
1,6 DT
21-22
13-14
8,9 RP
01
Slow-Action Contacts
2 NORMALLY CLOSED
21
22
2Y
12
11
15 mm
36,5
-4,4
21-22
11-12
FP
*
(F.P.)
(D.T.)
(O.P.)
26˚
(
*
)
46,5˚
(R.P.)
(O.T.)
61˚ to 75˚
FP
21 mm
18 mm
16,5 mm
*
15 mm
OT
(max.)
10,5
13,5
5,3 mm
21-22
11-12
FP
*
36
XX
GSS Series
OT
OT

Advertisement

loading