Codexml Protocol Compatibility - Honeywell FocusBT AP-010-BT Installation Manual

Access point device with bluetooth wireless technology
Hide thumbs Also See for FocusBT AP-010-BT:
Table of Contents

Advertisement

C
ONFIGURATION

CodeXML Protocol Compatibility

The CodeXML protocol does not support page/disconnect button functions, or
scanner firmware upgrades through the access point device and Metroset2.
When a scanner is using the CodeXML protocol, configuration data is stored in
the scanner. The stored data is not transmitted to the access point device.
Special configuration steps are required for the customization of system formats
and protocols. Instructions on how to configure a scanner in the CodeXML
protocol mode via the access point device are outlined on page 11.
Scanner Model
Focus BT
To configure a scanner to use the CodeXML protocol:
1.
Scan the Disable Metrologic Protocol bar code.
Disable Metro Protocol
³
1
2
5
2.
Scan the Recall Defaults bar code.
Recall Defaults
³
9
9
9
3.
Scan the Enable CodeXML Protocol bar code.
Enable CodeXML Protocol
³
1
2
5
4.
Scan the address bar code located on the top of the access point device
(see Figure 11, on page 8) to establish a communication link between the
scanner and access point.
5.
The scanner will beep to indicate a connection has been established.
10
www.metrologic.com
P
ROCEDURES
CodeXML Firmware Requirements
6
0
4
9
9
8
6
1
7
Firmware Version
15701 or higher