Download Print this page

Cisco Nexus 7000 Design Manual page 50

On flexpod with cisco nexus 7000 using fcoe
Hide thumbs Also See for Cisco Nexus 7000:

Advertisement

FlexPod Implementation and Design
Figure 22
Nodes 1 and 2 form a two-node storage failover pair through the HA interconnect direct connection. The
FlexPod design uses the following port and interface assignments:
Port 3a and 4a on each node support FCoE data traffic that is accessible through an FC LIF assigned
to SAN A or B (red or blue fabric).
Ethernet ports e3a and e4a on each node are members of a multimode LACP interface group for
Ethernet data. This interface group has a LIF associated with it to support NFS traffic.
Ports e0M are on each node and support a LIF dedicated to node management. Port e0b is defined
as a failover port supporting the "node_mgmt" role.
Ports e0a supports cluster management data traffic through the cluster management LIF. This port
and LIF allow for administration of the cluster from the failover port and LIF if necessary.
VMware vSphere 5.1 on FlexPod with Nexus 7000 Using FCoE
50
FlexPod Discrete Uplink Design - NetApp Storage Controller Focus

Advertisement

loading

This manual is also suitable for:

Vmware vsphere 5.1