Automatic Temperature Control; User Control Mode/Manual - Buffalo B100 Owner's Installation And Operation Manual

Wood pellet stove
Table of Contents

Advertisement

Automatic Temperature Control Mode (Ac)
Automatic Temperature Control Mode (Ac) is
the self-regulating, operational mode of the
stove. In this mode, the software adjusts the
feed rate, as well as the exhaust/combustion
and circulation blower speeds according to
the heat required to bring your home up to the
desired set point temperature (as selected on
your stove).
Set Point Temperature Adjustment
(Automatic Temp Control Mode)
• Depress and hold Set button
• Depress High or Low button (in
combination with Set button) to
adjust set point temperature*
(depressing and holding the High or
Low button in combination with the
Set button will adjust the set point
temperature at a rapid rate)
* Once set point temperature has
been set 2.1 degrees or more
below the current room
temperature, the stove will
initiate its controlled shut down
procedure.
In Automatic Temperature Control Mode (Ac)
the display will cycle between the letters Ac to
confirm that the stove is in Automatic
Temperature Control Mode and the current
room temperature.
User Control Mode / Manual Control (Uc)
User Control Mode (Uc) allows you to select a
continuous heat setting on your stove
between 3 and 7 (levels 1 and 2 are to be
used for diagnostic testing purposes only at
this time). The stove will feed pellets and run
the exhaust/combustion and circulation
blowers at preset speeds regardless of room
temperature. User Control Mode 0 will shut
the stove down. If the stove is shut down in
User Control Mode, changing the User
Control Mode setting from 0, to any number
between 3 and 7 will initiate a start-up
sequence. The lowest burn rate setting is
number 3, the highest burn rate setting is
number 7. To change the User Control Mode
setting (while in User Control Mode) follow the
instructions below.
User Control Mode Adjustment
• Depress and hold Set button
• Depress High or Low button (in
• Selecting User Control Mode 0 will
In User Control Mode (Uc) the display will
cycle between the letters Uc, to confirm that
the stove is in User Control Mode, the current
User Control Mode setting (0, 3-7) and the
current room temperature.
Set-up Mode - Feed Rate Adjustment
While in Automatic Temperature Control
Mode (Ac) it is possible to transfer into a set-
up mode, which enables the base feed rate of
the stove to be adjusted. If the stove is
operating in User Control Mode and the base
feed rate requires adjustment, the stove must
first be transferred into Automatic
Temperature Control Mode, then transferred
into Set-Up Mode. The base feed rate
adjustment made within set-up mode will
apply to all feed rate speeds of the stove. It is
necessary to be able to adjust the base feed
rate for each stove due to many factors,
including varying quality of fuel being burned,
the size of the area being heated within the
customer's home, the type of installation, as
well as other factors. Set-up Mode allows the
base feed rate for each stove to be fine tuned
to offset the affect of these various factors.
Page 21 of 37
combination with Set button) to
adjust the User Control Mode of the
stove (any number between 3 and
7)
shut down the stove