Automatic Temperature Control - Buffalo B100 Owner's Installation And Operation Manual

Wood pellet stove
Table of Contents

Advertisement

The "hot start" sequence takes 13 minutes
and 30 seconds. Once the stove has
completed the start-up sequence, it will
transfer control of the stove to either
Automatic Temperature Control Mode or User
Control Mode (manual control) depending
upon the mode the stove was in prior to the
initiation of the start-up sequence.
Automatic Temperature Control Mode /
User Control Mode
Your Buffalo Pellet stove hast two different
modes of operation, Automatic Temperature
Control Mode and User Control Mode
(manual control). The software enables the
stove to operate in either Automatic
Temperature Control Mode or User Control
Mode – Manual Control (both individually
described below).
In Automatic Temperature Control Mode, the
software will regulate all operational functions
of the stove (feed rate, combustion blower
speed and circulation blower speed) based
on the difference between your desired room
temperature (set point temperature) and what
the stove senses (through the temperature
sensing cable) your current room temperature
to be. In User Control Mode you will select a
continuous burn rate for you stove (0 or
between 3 and 7). The stove will burn pellets
at the selected feed rate regardless of the
current room temperature.
At initial power up the stove will default to
Automatic Temperature Control Mode. In
Automatic Temperature Control Mode (Ac)
the display will cycle between the letters Ac to
confirm that the stove is in Automatic
Temperature Control Mode and the current
room temperature.
If you wish to transfer from Automatic
Temperature Control Mode to User Control
mode, depress and hold the Low button, then
depress and hold the High button. After both
the Low and High buttons have been
depressed together for 2 seconds the stove
will transfer into User Control Mode (Uc). In
User Control Mode (Uc) the display will cycle
between the letters Uc to confirm that the
stove is in User Control Mode, the current
User Control Mode setting (0, 3-7) and the
current room temperature.
Transfer From Automatic Temp Control
Mode to User Control Mode (Manual
Control)
• Depress and hold Low button
• Depress and hold High button (in
• After both Low and High buttons
Transfer From User Control Mode (Manual
Control) to Automatic Temp Control Mode
• Depress and hold Low button
• Depress and hold High button (in
• After both Low and High buttons
* Note – Upon transfer from User Control
Mode to Automatic Temperature Control
Mode, the set point temperature on the
stove will default to the current room
temperature. Adjustments to the set
point temperature can be made using
the instructions below once transfer into
Automatic Temperature Control Mode is
complete.
Page 20 of 37
combination with Low button)
depressed for 2 seconds – transfer
to User Control
* Note – Upon transfer from
Automatic Temperature Control to
User Control, the default User
Control Mode setting is 3, if the
stove is not burning when transfer
from Automatic Temperature
Control to User Control occurs, a
start-up sequence will be initiated.
combination with Low button)
depressed for 2 seconds – transfer
to Automatic Temperature Control
Mode