Horizontal Through Wall - Buffalo B100 Owner's Installation And Operation Manual

Wood pellet stove
Table of Contents

Advertisement

2 feet below any overhang or eave
7 feet above grade when loca
adjacent to any pu
(Note: Vent may not terminate in
any covered walkway or
breezeway)
3 feet above any grass, plants or
other combustible ground
3 feet below
balcony
3 feet above any forced air inlet
located within 10 feet
3 feet fro
m any oil tank vent or gas
meter
10 feet from any adjac
line and/or buildings not owned by
the pel
let-burning appliance owner
Horizonta
l Through-Wall Installation
1. Taking into account all clearances that
must be maintained as identified
above, select the location for your
stove.
2.
Plan the exhaust system
3.
Determine and acquire the brand a
proper
size pellet vent pipe (PL) to be
used (use only one brand
pipe for the entire installation, do not
mix and match different pellet vent pipe
brands).
4.
Following the pellet vent
manufacturer's specifications, mark
and cut a
hole(s) through the wall to
accommodate the wall thi
outside air pipe if outside air is going
be provided). Take care to avoid
cutting wall studs, power lines, water
lines, etc. when cutting the hole for the
wall thimble.
5.
Install the wall thimble according to the
pellet vent manufacturer's instructions.
6.
Position the no
upon which the stove is going to be
placed, on the floor where the
appliance is going to be located.
7.
Insert the proper size and length pell
vent pipe through the wall thimb
ted
blic walkway
materials
any porch, deck or
ent property
of pellet vent
mble (and
n-combustible floor pad,
le.
8. Place the stove on the floor pad, close
to its final position, leaving space to
connect the pellet vent pipe to the rear
of the stove.
9.
Place a bead of high temp RTV
silicone around
pipe exiting your stove.
10.
Connect pellet vent pipe adapter to t
exhaust pipe exiting the s
minimum of 2 sheet metal screws to
attach the pipe adapter to the
appliance flue outlet (exhaust pipe) on
the stove.
11.
If 4-inch pellet vent is required, use a 3
to 4-inch pe
behind the pellet vent pipe adapter
attached in the step above.
12.
Connect the length of pellet vent pip
(which is passing through th
onto the pellet vent pipe adapter or 3
to 4-inch pellet vent adapter (if being
utilized).
13.
Place your stove in its final position on
the pad.
14. At a minimum, on the outside of the
building a
nd
45-degree PL type elbow onto the en
of the horizontal PL vent (45-degree
elbow location a minimum of 1 foot
from the outside surface of the
building)
15.
A more preferred exhaust syste
routing ou
the vent pipe out the side of the
building into a cleanout tee, then trav
5 to 8 feet vertically to a 90-degre
to
elbow (pointing away from the wall of
the structure), 12-inch horizontal pip
terminating with a down turned 45
degree elbow or horizontal cap. This
type of pipe routing outside the hom
will put a slight positive draft on the
exhaust system which will aid in
evacuating smoke from the applianc
in the event of a power failure.
16.
Once the entire exhaust system is
installed, using high temp RTV
et
silicone, seal the joint where the pe
vent pipe passes through the ins
and outside of the wall thimble.
Page 13 of 37
the outside exhaust
tove using a
llet vent adapter directly
e thimble)
ttach a downward directed
tside the home, is to bring
he
e
d
m
el
e
e,
e
e
llet
ide

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents