Connect The Keyboard; Installation; Figure 4 Connecting The Hegs5Blx Keyboard - Honeywell VideoBloX Quick Start Manual

Cross point matrix switch
Hide thumbs Also See for VideoBloX:
Table of Contents

Advertisement

Connect the Keyboard

Installation

TERMINAL
BLOCK
+12V
GND
RS232 TXD
RS232 RX
RJ11 Jack
6x6 Flat
Cable
RJ11 Jack
Rev 1.0
1.
Locate the HEGS5BLX controller, terminal block, 6x6 flat cable, power supply
(included with controller), HVB232422 converter, and power supply (included with
HVB232422 converter).
Figure 4
Connecting the HEGS5BLX Keyboard
HVB232422
RS232/RS422 Converter
Power Supply
12 VDC 2A
Pin 5, GND
Pin 3, RXD
Pin 2, TXD
-
+
HEGS5BLX KEYBOARD
2.
Connect the 6x6 flat cable between the RJ11 jack on the controller and the RJ11 jack
on the terminal block.
3.
Connect the RS232 cable with fly leads on one end and a male DB9 connector on the
other end.
a.
Connect the fly leads to the terminal block.
b.
Connect the male DB9 connector to the female DB9 connector on the
RS232/RS422 converter.
Female DB9
5
1
9
6
TX+
TX-
RX+
RX-
12-30 VDC Power Supply
Part #849193-0089
7
VideoBloX Quick Start Guide
VideoBloX CPU Module
RS422 Master
Female DB9
Pin 3, RX+
Pin 4, RX-
Pin 2, TX+
Pin 1, TX-
Pin 5, GND
Document 900.0840