Power Cord

Before installing the power cord, read through
SECTION 2: CIRCUIT REQUIREMENTS to
check that your setup follows the safety and
circuit requirements, and the power cord and
power disconnect that you have chosen meet the
requirements for this machine.
Components and Hardware Needed:
Power Cord (Not Included) .................................1
To connect the sander to the power source:
1.
Remove the screws securing the control
panel and lift off the face plate.
Figure 13. G0449 control panel wiring.
2.
Feed the power cord through the strain relief
on the bottom of the control panel, tighten
the strain relief, connect the cord to the ter-
minals shown in Figure 13 or 14, and close
the control panel.
Note For Model G0450 Only: When using a
phase converter, connect the manufactured
power leg to the L2 terminal (Figure 14).
The L2 terminal can handle power fluctuation
because it is wired directly to the motor. The
other wires connect to the controls and must
be consistent to prevent damage.
G0449/G0450 37" Drum Sander
Qty
Figure 14. G0450 control panel wiring.
3.
Shut off the main power at the power
source circuit breaker and install the cord
to the power disconnect.

Gear Oil Check

It is important to make sure the gear box has oil in
it before running the sander for the first time. This
is to ensure the gears do not burn up.
To check the gear oil:
1.
Remove the feed motor cover, and check the
sight glass shown in Figure 15 to make sure
gear oil is present.
Figure 15. Location to check gear box oil level.
2.
If the gearbox oil level is low, follow the steps
on Page 26 to refill the oil.